GROADA-AC346V-50KVA-RL resistive inductive load bank
GROADA AC346V-50KVA RL AC Load Bank is a high-precision resistive-inductive (RL) load cabinet design...
| Model | AC220V-6KW-R | AC380V-30KW-R | AC380V-60KW-R | AC380V-100KW-R | AC380V-200KW-R | AC380V-400KW-R | AC380V-500KW-R | AC380V-1000KW-R |
| Rated power | 0-6KW | 0-30KW | 0-60KW | 0-100KW | 0-200KW | 0-400KW | 0-500KW | 0-1000KW |
| Size (width * depth * height mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Weight | 25KG | 80KG | 130KG | 180KG | 250KG | 550KG | 650KG | 1100KG |
| Input current | 0-30A | 0-45A | 0-90A | 0-150A | 0-300A | 0-600A | 0-750A | 0-1500A |
| Minimum loading | 100W | 100W | 500W | 1KW | 1KW | 5KW | 10KW | 50KW |
| Other minimum loading power can be customized according to requirements | ||||||||
| Input voltage | AC220/230V | AC380/400V | ||||||
| Other input voltage can be customized according to requirements | ||||||||
| Power | PF=1.0 | |||||||
| Overall accuracy | 3% (other accuracy requirements can be customized according to requirements) | |||||||
| Control mode | Local manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required) | |||||||
| Remote Interface | RS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements) | |||||||
| Protection function | Emergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume) | |||||||
| Working power supply | AC220V | AC220V/380V | AC380V | |||||
| Display accuracy | 0.5 level (other explicit precision can be customized according to requirements | |||||||
| Display parameters | Voltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements) | |||||||
| Cold sure way | Forward and out | Side air inlet and upper air outlet (other air outlet methods can be customized according to requirements) | ||||||
| Protection level | IP20 (other protection level can be customized according to requirements) | |||||||
| Appearance color | RAL7035 (other colors can be customized according to requirements) | |||||||
| Working temperature | -10 ℃ ~ 55 ℃ | |||||||
| Relative humidity | ≤95%RH | |||||||
| Altitude | ≤ 2500 m | |||||||
The GROADA AC480V 200KW-R Resistive Load Bank represents the pinnacle of power system testing solutions, engineered for industrial-grade reliability, precision, and safety. Designed for modern AC power systems, this load bank enables thorough evaluation of generators, UPS systems, and critical infrastructure under realistic load conditions.
High-Capacity Testing: Rated at 200 kW, the AC480V 200KW-R delivers robust performance for testing medium to large-scale AC power systems with accuracy and stability.
Wide Voltage Compatibility: Engineered for 480V operation, suitable for diverse industrial applications and international standards compliance.
Pure Resistive Load: Offers true resistive testing, accurately simulating operational loads to validate system capacity without introducing inductive or capacitive distortions.
Advanced Safety Mechanisms: Integrated features include over-temperature protection, branch circuit fuses, and secure quick-connect cables, ensuring safe and uninterrupted operation.
Intuitive Control Interface: Equipped with a digital LED display, individual fan switches, load step controls, and master load control, providing operators precise, user-friendly load management.
The AC480V 200KW-R load bank is indispensable for industries requiring robust power system validation:
Generator Testing: Ensures generators operate at full-rated capacity under continuous or peak loads.
UPS & Emergency Power Systems: Validates UPS performance, crucial for mission-critical facilities such as data centers, hospitals, and telecommunications.
Industrial & Manufacturing Facilities: Confirms the reliability of power systems under production and operational stress.
Data Center Infrastructure: Simulates full-load conditions to safeguard backup power and ensure uninterrupted digital operations.
GROADA load banks adhere to rigorous international testing standards, supporting operational longevity and safety. Routine load bank testing is recommended by NFPA 110 and other global standards for emergency power systems. By incorporating this load bank into your maintenance protocols, you enhance reliability, extend equipment life, and ensure regulatory compliance.
Precision Engineering: Realistic load simulation for accurate testing outcomes.
Durability & Longevity: Built with high-quality components for heavy-duty industrial environments.
Ease of Operation: Clear digital controls and safety features for streamlined operation.
Global Support Network: GROADA provides comprehensive after-sales service, ensuring continuous operational readiness.
The GROADA AC480V 200KW-R Resistive Load Bank is more than a testing tool—it is a guarantee of operational confidence. By simulating real-world loads with precision and ensuring compliance with international standards, it becomes an essential asset for power system engineers, facility managers, and industrial operators who demand reliability, safety, and excellence.