GROADA-AC346V-50KVA-RL 저항 유도 부하 은행
GROADA AC346V-50KVA RL AC Load Bank is a high-precision resistive-inductive (RL) load cabinet design...
| 모델 | AC220V-10KVA-RL | AC380V-30KVA-RL는 | AC380V-60KVA-RL는 | AC380V-100KVA-RL는 | AC380V-300KVA-RL는 | AC380V-500KVA-RL는 | AC380V-1000KVA-RL는 |
| 정격 전력 | RL = 10KVA | RL = 30KVA | RL = 60KVA | RL = 100KVA | RL = 300KVA | RL = 500KVA | RL = 1000KVA |
| R = 10KW;L = 6KVA | R=30KW;L = 18KVA | R=60KW;L = 36KVA | R=100KW;L = 60KVA | R=300KW;L = 180KVA | R = 500KW;L = 300KVA | R = 1000KW;L = 600KVA | |
| 입력 현재 | 0-45A | 0-45A | 0-90A | 0-150A | 0-450A | 0-750A | 0-1500A |
| 크기 (폭 * 깊이 * 높이 mm) | 480*600*277 | 480*600*360 | 500*750*1000 | 600*850*1000 | 700*1000*1650 | 1100*1400*1700 | 1100*1500*1900 |
| 무게 | 25KG의 | 40KG의 | 80KG의 | 130KG의 | 250KG의 | 550KG의 | 750KG의 |
| 최소 부하 | 100W | 100W | 100W | 500W | 1KW | 5KW의 | 10KW의 |
| 다른 최소 적재 힘은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | |||||||
| 입력 전압 | AC220 / 230V | AC380/400V | |||||
| 다른 입력 전압은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | |||||||
| 전력 요소 | PF = 0.8/1.0 (다른 전력 요인은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 전반적인 정확도 | 3% (다른 정확도 요구 사항은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 제어 모드 | 지역 수동/원격 호스트 컴퓨터 (지역 수동 제어 모드: 차단기/버튼/터치 스크린 선택적 3 방향, 다른 방법은 필요에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 원격 인터페이스 | RS232/RS485/USB/RJ45/CAN/GPIB (다른 인터페이스 형태는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 보호 기능 | 비상 정지 보호, 과온 보호, 팬 부하 인터로크 보호, 접지 보호 (과전압 보호, 과전류 보호, 단회로 보호, 팬 과부하, 부족한 공기 용량을 선택하십시오) | ||||||
| 작동 전원 공급 | AC220V는 | AC220V / 380V | AC380V는 | ||||
| 표시 정확도 | 0.5 수준 (다른 명시적인 정밀도는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 표시 매개 변수 | 전압, 전류, 힘, 주파수, 전력 요인 등. (다른 명시적인 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 차가운 확실한 방법 | 측면 공기 입구 및 위 공기 출구 (다른 공기 출구 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 보호 수준 | IP20 (다른 보호 수준은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 외관 색깔 | RAL7035 (다른 색깔은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 작동 온도 | -10 ℃ ~ 55 ℃ | ||||||
| 상대 습도 | ≤95%RH | ||||||
| 고도 | ≤ 2500 m | ||||||
GROADA AC346V-50KVA RL AC 부하 은행높은 정밀도입니다.저항 유도 (RL) 로드 캐비넷같은 전력 장비의 테스트 및 검증을 위해 설계되었습니다.발전기, UPS 시스템, 인버터, 데이터 센터 및 산업용 전원 공급 장치.
이 모델은 지원합니다.정확한 전력 요소 조정 (0.8에서 0.8까지 지연)모듈형 확장, 고급 냉각 설계 및 지능형 보호 메커니즘은 요구적인 응용 프로그램에서 안정적이고 신뢰할 수 있는 성능을 보장합니다.
정격 힘:50킬로볼트암페어
정격 전압:346 V AC (380 V/400 V/415 V를 위해 사용자 정의 가능한)
부하 유형:Resistive + Inductive
조정가능한 전력 요인:0.8 lagging ~ 1.0 ~ 0.8 leading
Modular Design: expandable by parallel connection
냉각:high-efficiency forced air cooling
Protection: overload, overheat, short-circuit, fan failure alarm
Control & Communication: manual panel + RS-485/Modbus/Ethernet remote monitoring
Applications: power plants, generator testing, UPS aging test, renewable energy systems, EV charging stations
| 매개 변수 | Value |
|---|---|
| 정격 전력 | 50킬로볼트암페어 |
| 전압 범위 | 300 – 380 V AC (custom options) |
| 로드 유형 | Resistive + Inductive (RL) |
| Power Factor Adjustment | 0.8 lagging ~ 1.0 ~ 0.8 leading |
| 냉각 시스템 | Forced air cooling, top exhaust |
| Protection Functions | Overload / Overheat / Short circuit / Fan failure |
| 제어 모드 | Manual local control + Remote monitoring |
| Communication Protocols | RS-485 / Modbus / Ethernet |
| Cabinet Design | Rugged enclosure, IP protection customizable |
| Working Temperature | –10℃ ~ +45℃ |
The load bank integrates resistive elements그리고inductive coils in modular sections.
Load Control: PWM control enables precise step adjustment of load capacity.
Power Factor Simulation: Supports real-time adjustment to simulate inductive and capacitive conditions.
Protection Mechanism: Temperature sensors, fan monitoring, automatic unloading in case of fault.
냉각 시스템: High-volume fans ensure fast heat dissipation and safe operation under full load.
Smart Monitoring: Remote control and data logging via Modbus or Ethernet.
Power Generation: Testing diesel / gas generators under full load and transient conditions.
UPS 시스템: Long-time aging tests and reliability verification.
Renewable Energy: Grid-tie inverter and photovoltaic system validation.
데이터 센터: Simulating real IT load for facility acceptance.
EV Charging Stations: Power electronics and charging infrastructure testing.
Compared with traditional load banks, GROADA AC load banks deliver:
Higher accuracy in power factor adjustment.
Better thermal management with forced air cooling.
Modular and expandable architecture for flexible capacity.
Advanced safety protections ensuring long service life.
Remote monitoring & control for modern test environments.
When choosing a load bank:
정격 전력 ≥ 1.2 × tested equipment rated power.
Voltage Level must match system (300–380V standard, custom for 400/415/480V).
전력 인자: choose RL load bank if your DUT (device under test) involves inductive / capacitive behaviors.
Environment: outdoor use requires higher IP protection and enhanced cooling.
Q1: Can the load bank run continuously at full power?
Yes, with proper ventilation, it can sustain continuous full-load operation.
Q2: How often should maintenance be performed?
Every 6–12 months: check fans, wiring terminals, resistance modules, and clean dust.
Q3: Does it support remote monitoring?
Yes, via RS-485 / Modbus / Ethernet for data logging, alarm, and control.
Q4: What protection functions are included?
Overload, overheat, short-circuit, and fan failure detection with automatic load disconnection.
ISO 9001 / ISO 14001 certified manufacturer
CE / UL compliance (upon request)
Factory type test reports available (temperature rise, EMC, insulation, durability)
Warranty: 12 months, with global technical support
“We deployed GROADA RL load banks for generator testing in our European facility. The precision and stability exceeded expectations.” — John M., Germany
“Reliable partner for UPS verification projects. Remote monitoring makes operation much easier.” — David P., UK
📩 Email: groada@163.com
☎ Phone: +86 13342997981
📍 Address: Shenzhen, China
👉 Request a Quote or Free Consultation today!