GROADA-AC380V-150KW-RL 저항 부하 은행
The GROADA-AC380V-150KW-RL resistive load bank is a high-performance testing device designed to simu...
| 모델 | AC220V-10KVA-RL | AC380V-30KVA-RL는 | AC380V-60KVA-RL는 | AC380V-100KVA-RL는 | AC380V-300KVA-RL는 | AC380V-500KVA-RL는 | AC380V-1000KVA-RL는 |
| 정격 전력 | RL = 10KVA | RL = 30KVA | RL = 60KVA | RL = 100KVA | RL = 300KVA | RL = 500KVA | RL = 1000KVA |
| R = 10KW;L = 6KVA | R=30KW;L = 18KVA | R=60KW;L = 36KVA | R=100KW;L = 60KVA | R=300KW;L = 180KVA | R = 500KW;L = 300KVA | R = 1000KW;L = 600KVA | |
| 입력 현재 | 0-45A | 0-45A | 0-90A | 0-150A | 0-450A | 0-750A | 0-1500A |
| 크기 (폭 * 깊이 * 높이 mm) | 480*600*277 | 480*600*360 | 500*750*1000 | 600*850*1000 | 700*1000*1650 | 1100*1400*1700 | 1100*1500*1900 |
| 무게 | 25KG의 | 40KG의 | 80KG의 | 130KG의 | 250KG의 | 550KG의 | 750KG의 |
| 최소 부하 | 100W | 100W | 100W | 500W | 1KW | 5KW의 | 10KW의 |
| 다른 최소 적재 힘은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | |||||||
| 입력 전압 | AC220 / 230V | AC380/400V | |||||
| 다른 입력 전압은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | |||||||
| 전력 요소 | PF = 0.8/1.0 (다른 전력 요인은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 전반적인 정확도 | 3% (다른 정확도 요구 사항은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 제어 모드 | 지역 수동/원격 호스트 컴퓨터 (지역 수동 제어 모드: 차단기/버튼/터치 스크린 선택적 3 방향, 다른 방법은 필요에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 원격 인터페이스 | RS232/RS485/USB/RJ45/CAN/GPIB (다른 인터페이스 형태는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 보호 기능 | 비상 정지 보호, 과온 보호, 팬 부하 인터로크 보호, 접지 보호 (과전압 보호, 과전류 보호, 단회로 보호, 팬 과부하, 부족한 공기 용량을 선택하십시오) | ||||||
| 작동 전원 공급 | AC220V는 | AC220V / 380V | AC380V는 | ||||
| 표시 정확도 | 0.5 수준 (다른 명시적인 정밀도는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 표시 매개 변수 | 전압, 전류, 힘, 주파수, 전력 요인 등. (다른 명시적인 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 차가운 확실한 방법 | 측면 공기 입구 및 위 공기 출구 (다른 공기 출구 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 보호 수준 | IP20 (다른 보호 수준은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 외관 색깔 | RAL7035 (다른 색깔은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||
| 작동 온도 | -10 ℃ ~ 55 ℃ | ||||||
| 상대 습도 | ≤95%RH | ||||||
| 고도 | ≤ 2500 m | ||||||
TheGROADA AC380V 200 kW RL 저항 반응 부하 은행설계된 전문 등급 시험 장치입니다발전기 세트, UPS 시스템, 데이터 센터, 해양 전력 시스템 및 전기 시작 프로젝트.
그것은 제공저항 및 유도 부하 시뮬레이션 (일반적으로 0.8 지연 전력 요소), a 보장종합적이고 현실적인 테스트실제 운영 조건에서 전력 시스템.
만들어진산업용 급료 부품그리고고정확도 측정 시스템이 단위는 중요한 전력 검증을 위해 안정적이고 안전하고 반복 가능한 성능을 제공합니다.
지원저항 (1.0 PF)그리고저항 + 유도 (0.8 PF)작업.
모터, 변압기 및 유도 부하의 실제 전기 특성을 시뮬레이션하는 데 이상적입니다.
사용자가 실제 스트레스 조건에서 시스템 안정성, 전력 요인 및 전압 조절을 분석할 수 있습니다.
Output accuracy up to ±0.5% ensures dependable test results.
Stepwise load control allows gradual and safe power ramping.
Continuous monitoring of voltage, current, power, and PF for precise data collection.
Integrated protection: overload, over-temperature, short-circuit그리고fan failure alarm.
Modular resistor and inductor assemblies simplify inspection and service.
Compact cabinet design suitable for laboratory, plant room, or field testing environments.
High-efficiency air cooling system maintains stable operation under continuous load.
Optional remote monitoring system for data acquisition and real-time control.
Intuitive control interface with touch screen or switch panel.
Supports parallel operation with other load banks for expanded capacity.
| 매개 변수 | 명세 |
|---|---|
| 정격 전력 | 200kW |
| 정격 전압 | 380 V AC, 3-phase |
| 전력 인자 | 1.0 (resistive) / 0.8 (inductive) |
| Load Step | Customizable (e.g. 5 kW or 10 kW per step) |
| Accuracy | ±0.5% |
| 냉각 | Forced air cooling |
| Protection | Overload, over-temperature, short circuit |
| Operating Temperature | –20 °C to +50 °C |
| Enclosure | Indoor/Outdoor, IP54 |
| 제어 모드 | Local / Remote |
| Data Interface | Optional RS485 / Ethernet / MODBUS |
Generator commissioning and performance validation
UPS and inverter testing in data centers and telecom facilities
Periodic maintenance to prevent generator wet stacking
Marine power system simulation and verification
Load sharing and synchronization tests for parallel generators
Factory acceptance tests (FAT) and on-site commissioning
Comprehensive testing for both real and reactive load performance
Improved power factor analysis for optimizing generator performance
Enhanced safety through automated protections and precision control
Global standard compliance (IEC, GB, ISO) ensuring international reliability
Engineered by professionals with years of expertise in load testing and power simulation
According to recent industry reports, the global load bank market is projected to grow from USD 288 million in 2024 to USD 387 million by 2032, driven by the expansion of data centers, renewable energy systems, and industrial backup power solutions.
The demand for resistive-reactive load banks is especially increasing, as more users seek to replicate realistic electrical environments for accurate generator and UPS testing.
This market trend highlights the value of GROADA’s advanced RL load bank solutions, which combine high precision, flexible configuration, and durable performance for modern power infrastructure projects.
Connect the load bank to your generator or UPS system securely.
Perform no-load checks for voltage and frequency stability.
Gradually apply load steps (resistive or inductive) up to the desired level.
Monitor system response — voltage, current, PF, and temperature.
Record test data for analysis and maintenance documentation.
After testing, reduce load to zero and allow cooling fans to run for several minutes.
Inspect components before disconnecting and storage.
Over 10 years of engineering expertise in power testing equipment
Customizable solutions from 10 kW to 5 MW load capacity
Exported to over 50 countries worldwide
Supported by a dedicated technical and after-sales service team
Proven reliability in harsh industrial and offshore environments
GROADA’s mission is to provide trusted and innovative load testing solutions that ensure safety, stability, and efficiency for global power systems.
Q1: What does RL mean in load banks?
RL means Resistive + Inductive. It combines resistive elements that draw real power (kW) and inductive coils that draw reactive power (kVAR), simulating real-world electrical loads with lagging power factor.
Q2: Why is reactive load testing important?
Reactive testing helps evaluate generator voltage regulation, power factor correction capability, and transient response — critical factors for reliable system operation.
Q3: Can GROADA RL load banks operate outdoors?
Yes, optional weatherproof enclosures (IP54/IP55) make them suitable for outdoor or mobile applications.
Q4: Can multiple load banks be paralleled?
Yes, GROADA RL load banks can be connected in parallel to achieve higher power capacity or multi-system testing.
Q5: How often should load bank testing be done?
Industry best practice recommends at least once a year for standby generators or UPS systems to ensure reliable performance and avoid carbon buildup.
GROADA is a professional manufacturer of industrial load banks and power testing equipment.
We specialize in resistive, inductive, capacitive, and combined load banks from 10 kW to 5 MW, serving industries such as energy, telecom, marine, and manufacturing.
Our products are exported globally and recognized for quality, durability, and engineering precision.
Every GROADA load bank is designed to meet international standards (IEC/GB) and undergoes strict factory testing to ensure optimal performance.