Load Bank

GROADA-AC415V-600KW-R of generator resistance load bank

★★★★★
Main Products:
  • AC Load Bank : R / RL / RLC / RCD
  • DC Load Bank : DC5V - 2000V, 0A - 5000A


ModelAC220V-6KW-RAC380V-30KW-RAC380V-60KW-RAC380V-100KW-RAC380V-200KW-RAC380V-400KW-RAC380V-500KW-RAC380V-1000KW-R
Rated power0-6KW0-30KW0-60KW0-100KW0-200KW0-400KW0-500KW0-1000KW
Size (width * depth * height mm)480*600*277500*750*1000600*850*1000600*850*1400700*1000*16501100*1400*17001100*1400*18001500*1800*2000
Weight25KG80KG130KG180KG250KG550KG650KG1100KG
Input current0-30A0-45A0-90A0-150A0-300A0-600A0-750A0-1500A
Minimum loading100W100W500W1KW1KW5KW10KW50KW
Other minimum loading power can be customized according to requirements
Input voltageAC220/230VAC380/400V
Other input voltage can be customized according to requirements
PowerPF=1.0
Overall accuracy3% (other accuracy requirements can be customized according to requirements)
Control modeLocal manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required)
Remote InterfaceRS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements)
Protection functionEmergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume)
Working power supplyAC220VAC220V/380VAC380V
Display accuracy0.5 level (other explicit precision can be customized according to requirements
Display parametersVoltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements)
Cold sure wayForward and outSide air inlet and upper air outlet (other air outlet methods can be customized according to requirements)
Protection levelIP20 (other protection level can be customized according to requirements)
Appearance colorRAL7035 (other colors can be customized according to requirements)
Working temperature-10 ℃ ~ 55 ℃
Relative humidity≤95%RH
Altitude≤ 2500 m



GROADA AC415V-600KW-R Resistive Load Bank: Comprehensive Power System Testing Solution


🔍 Product Overview

The GROADA AC415V-600KW-R Resistive Load Bank is engineered to simulate real-world electrical loads, providing a robust solution for testing and validating the performance of power systems. With a capacity of 600 kW at 415V AC, this load bank is ideal for applications requiring high power testing, ensuring that generators, uninterruptible power supplies (UPS), and other critical power infrastructure operate efficiently under full-rated loads.


⚙️ Key Features

  • High Power Capacity: Supports up to 600 kW at 415V AC, accommodating large-scale power systems.

  • Resistive Load Simulation: Emulates real-world operational conditions, providing accurate testing environments.

  • Continuous Operation: Designed for prolonged use, ensuring reliability during extended testing periods.

  • User-Friendly Interface: Equipped with intuitive controls for easy operation and monitoring.

  • Robust Construction: Built to withstand demanding environments, ensuring longevity and consistent performance.


🛠️ Applications

The AC415V-600KW-R Resistive Load Bank is versatile and suitable for various applications:

  • Generator Testing and Maintenance: Verifies that generators can handle full-rated loads, preventing potential failures during critical operations.

  • UPS Systems Validation: Ensures UPS systems provide uninterrupted power during outages by simulating real-world load conditions.

  • Power System Commissioning: Facilitates the commissioning of new power installations by simulating operational loads.

  • Routine Maintenance: Supports regular maintenance schedules to identify and rectify potential issues before they lead to system failures.


✅ Benefits

Utilizing the GROADA AC415V-600KW-R Resistive Load Bank offers several advantages:

  • Enhanced Reliability: Regular testing ensures power systems perform optimally, reducing the risk of unexpected failures.

  • Cost Savings: Identifying issues early through load testing can prevent costly repairs and downtime.

  • Compliance Assurance: Meets industry standards and regulations, ensuring compliance and safety.

  • Extended Equipment Lifespan: Regular load testing can prolong the life of power equipment by ensuring it operates within its designed parameters.


📈 Industry Insights

The global load bank market is experiencing significant growth, driven by increasing industrialization and the need for reliable power systems. According to industry reports, the market is projected to reach USD 412.9 million by 2032, growing at a CAGR of 4.5% from 2025 to 2032. 

This growth underscores the importance of investing in high-quality testing equipment like the GROADA AC415V-600KW-R to ensure the reliability and efficiency of power systems across various industries.


📞 Contact Information

For more information or to request a quote, please contact:

  • Email: groada@163.com

  • Phone: +86-755-23339096

  • Address: Shenzhen, Guangdong, China

Our Product