GROADA-AC600V-25KW-RCD inverter load bank
The GROADA AC600V-25kW RCD Load Bank is a professional testing device designed to simulate real-worl...
| Model | AC220V-6KW-R | AC380V-30KW-R | AC380V-60KW-R | AC380V-100KW-R | AC380V-200KW-R | AC380V-400KW-R | AC380V-500KW-R | AC380V-1000KW-R |
| Rated power | 0-6KW | 0-30KW | 0-60KW | 0-100KW | 0-200KW | 0-400KW | 0-500KW | 0-1000KW |
| Size (width * depth * height mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Weight | 25KG | 80KG | 130KG | 180KG | 250KG | 550KG | 650KG | 1100KG |
| Input current | 0-30A | 0-45A | 0-90A | 0-150A | 0-300A | 0-600A | 0-750A | 0-1500A |
| Minimum loading | 100W | 100W | 500W | 1KW | 1KW | 5KW | 10KW | 50KW |
| Other minimum loading power can be customized according to requirements | ||||||||
| Input voltage | AC220/230V | AC380/400V | ||||||
| Other input voltage can be customized according to requirements | ||||||||
| Power | PF=1.0 | |||||||
| Overall accuracy | 3% (other accuracy requirements can be customized according to requirements) | |||||||
| Control mode | Local manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required) | |||||||
| Remote Interface | RS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements) | |||||||
| Protection function | Emergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume) | |||||||
| Working power supply | AC220V | AC220V/380V | AC380V | |||||
| Display accuracy | 0.5 level (other explicit precision can be customized according to requirements | |||||||
| Display parameters | Voltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements) | |||||||
| Cold sure way | Forward and out | Side air inlet and upper air outlet (other air outlet methods can be customized according to requirements) | ||||||
| Protection level | IP20 (other protection level can be customized according to requirements) | |||||||
| Appearance color | RAL7035 (other colors can be customized according to requirements) | |||||||
| Working temperature | -10 ℃ ~ 55 ℃ | |||||||
| Relative humidity | ≤95%RH | |||||||
| Altitude | ≤ 2500 m | |||||||
The GROADA-AC220V-30KW-R resistance AC load bank is engineered for rigorous testing and maintenance of electrical power systems. Capable of simulating real-world operational loads, this load bank ensures the reliability and performance of backup power sources such as generators, uninterruptible power supplies (UPS), and other critical infrastructure components.
High Capacity: Delivers up to 30 kW of resistive load, accommodating a wide range of testing scenarios.
Versatile Applications: Ideal for commissioning, maintenance, and periodic testing of power systems in data centers, industrial facilities, and power generation plants.
Robust Construction: Designed to withstand demanding testing environments, ensuring longevity and consistent performance.
User-Friendly Interface: Equipped with intuitive controls and monitoring systems for ease of operation and data analysis.
Data Centers: Load banks are essential for testing backup power systems, ensuring that generators and UPS units can handle full operational loads without failure. This is crucial for maintaining uptime and preventing costly outages.
Industrial Facilities: Regular load testing helps identify potential issues in power systems before they lead to equipment failure, thereby enhancing operational efficiency and safety.
Power Generation Plants: Simulating load conditions allows for the verification of generator performance and the detection of any anomalies that could impact power supply stability.
The global load bank market is experiencing significant growth, driven by increasing industrialization and the rising demand for reliable power systems. The market is projected to reach USD 412.9 million by 2032, growing at a compound annual growth rate (CAGR) of 4.5% from 2025 to 2032.
In particular, the Asia Pacific region, including countries like China and India, is witnessing rapid industrial growth, leading to a heightened demand for load banks in various sectors such as manufacturing, telecommunications, and energy.
Enhanced Reliability: Ensures that power systems perform optimally under full load conditions, reducing the risk of unexpected failures.
Cost Efficiency: By identifying potential issues early, load testing can prevent costly repairs and downtime.
Compliance Assurance: Helps meet industry standards and regulations for power system performance and safety.
Scalability: Suitable for a wide range of applications, from small-scale facilities to large industrial plants.
The GROADA-AC220V-30KW-R resistance AC load bank is a vital tool for ensuring the reliability and efficiency of electrical power systems. Its robust design, high capacity, and versatility make it an indispensable asset for industries where uninterrupted power supply is critical.