GROADA-AC600V-25KW-RCD inverter load bank
The GROADA AC600V-25kW RCD Load Bank is a professional testing device designed to simulate real-worl...
| Model | AC220V-10KVA-RL | AC380V-30KVA-RL | AC380V-60KVA-RL | AC380V-100KVA-RL | AC380V-300KVA-RL | AC380V-500KVA-RL | AC380V-1000KVA-RL |
| Rated power | RL=10KVA | RL=30KVA | RL=60KVA | RL=100KVA | RL=300KVA | RL=500KVA | RL=1000KVA |
| R=10KW;L=6KVA | R=30KW;L=18KVA | R=60KW;L=36KVA | R=100KW;L=60KVA | R=300KW;L=180KVA | R=500KW;L=300KVA | R=1000KW;L=600KVA | |
| Input current | 0-45A | 0-45A | 0-90A | 0-150A | 0-450A | 0-750A | 0-1500A |
| Size (width * depth * height mm) | 480*600*277 | 480*600*360 | 500*750*1000 | 600*850*1000 | 700*1000*1650 | 1100*1400*1700 | 1100*1500*1900 |
| Weight | 25KG | 40KG | 80KG | 130KG | 250KG | 550KG | 750KG |
| Minimum loading | 100W | 100W | 100W | 500W | 1KW | 5KW | 10KW |
| Other minimum loading power can be customized according to requirements | |||||||
| Input voltage | AC220/230V | AC380/400V | |||||
| Other input voltage can be customized according to requirements | |||||||
| power factor | PF = 0.8/1.0 (other power factor can be customized according to requirements) | ||||||
| Overall accuracy | 3% (other accuracy requirements can be customized according to requirements) | ||||||
| Control mode | Local manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required) | ||||||
| Remote Interface | RS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements) | ||||||
| Protection function | Emergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume) | ||||||
| Working power supply | AC220V | AC220V/380V | AC380V | ||||
| Display accuracy | 0.5 level (other explicit precision can be customized according to requirements) | ||||||
| Display parameters | Voltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements) | ||||||
| Cold sure way | Side air inlet and upper air outlet (other air outlet methods can be customized according to requirements) | ||||||
| Protection level | IP20 (other protection level can be customized according to requirements) | ||||||
| Appearance color | RAL7035 (other colors can be customized according to requirements) | ||||||
| Working temperature | -10 ℃ ~ 55 ℃ | ||||||
| Relative humidity | ≤95%RH | ||||||
| Altitude | ≤ 2500 m | ||||||
TheGROADA Electronic Load Cabinet 15A/12-Ris a state-of-the-art, rack-mounted AC resistive load bank, engineered for rigorous testing and validation of electrical power sources. Designed for professionals in sectors such as data centers, telecommunications, and industrial facilities, this unit ensures that your power systems perform optimally under full-load conditions.
High-Precision Load Simulation: Offers precise resistive loading up to 15A per phase, enabling accurate simulation of real-world operating conditions.
Compact Rack-Mounted Design: Optimized for space-constrained environments, facilitating easy integration into existing setups.
User-Friendly Interface: Equipped with intuitive controls and digital displays for straightforward operation and monitoring.
Robust Build Quality: Constructed with high-quality materials to ensure durability and long-term reliability.
Versatile Application: Suitable for testing a wide range of equipment, including UPS systems, inverters, and backup generators.
Input Voltage: AC 220V
Maximum Output Current: 15A per phase
Load Type: Resistive
Form Factor: Rack-mounted
Cooling Method: Forced air
Compliance Standards: Meets international safety and performance standards
UPS Systems: Validate the performance and capacity of uninterruptible power supplies to ensure reliability during power outages.
Inverter Testing: Assess the efficiency and functionality of inverters in renewable energy setups.
Generator Load Testing: Simulate load conditions to verify the operational readiness of backup generators.
Data Centers: Conduct routine maintenance and performance checks to prevent unexpected downtimes.
According to recent industry analyses, the global load bank market is experiencing significant growth, driven by the increasing demand for reliable power systems across various sectors. Regular load bank testing is essential for identifying potential issues before they lead to system failures, thereby enhancing the overall reliability and efficiency of power infrastructure.
To maximize the effectiveness of your load bank testing:
Regular Testing: Conduct load bank tests at least annually to ensure equipment reliability.
Comprehensive Load Application: Apply loads incrementally up to the maximum rating to thoroughly assess system performance.
Safety Protocols: Implement appropriate safety measures, including PPE and proper ventilation, to mitigate risks during testing.
Documentation: Maintain detailed records of test results and any anomalies to inform future maintenance and upgrades.
TheGROADA Electronic Load Cabinet 15A/12-Rstands out in the market for its precision, reliability, and user-centric design. By integrating this load bank into your testing protocols, you ensure that your power systems are thoroughly vetted, reducing the risk of unexpected failures and enhancing operational continuity.
For more information or to request a quote, please contact us:
📧Email:groada@163.com
📞Phone: 0755-23339096