Load Bank

Electronic load cabinet-15A/12-R

★★★★★
Main Products:
  • AC Load Bank : R / RL / RLC / RCD
  • DC Load Bank : DC5V - 2000V, 0A - 5000A


ModelAC220V-10KVA-RLAC380V-30KVA-RLAC380V-60KVA-RLAC380V-100KVA-RLAC380V-300KVA-RLAC380V-500KVA-RLAC380V-1000KVA-RL
Rated powerRL=10KVARL=30KVARL=60KVARL=100KVARL=300KVARL=500KVARL=1000KVA
R=10KW;L=6KVAR=30KW;L=18KVAR=60KW;L=36KVAR=100KW;L=60KVAR=300KW;L=180KVAR=500KW;L=300KVAR=1000KW;L=600KVA
Input current0-45A0-45A0-90A0-150A0-450A0-750A0-1500A
Size (width * depth * height mm)480*600*277480*600*360500*750*1000600*850*1000700*1000*16501100*1400*17001100*1500*1900
Weight25KG40KG80KG130KG250KG550KG750KG
Minimum loading100W100W100W500W1KW5KW10KW
Other minimum loading power can be customized according to requirements
Input voltageAC220/230VAC380/400V
Other input voltage can be customized according to requirements
power factorPF = 0.8/1.0 (other power factor can be customized according to requirements)
Overall accuracy3% (other accuracy requirements can be customized according to requirements)
Control modeLocal manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required)
Remote InterfaceRS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements)
Protection functionEmergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume)
Working power supplyAC220VAC220V/380VAC380V
Display accuracy0.5 level (other explicit precision can be customized according to requirements)
Display parametersVoltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements)
Cold sure waySide air inlet and upper air outlet (other air outlet methods can be customized according to requirements)
Protection levelIP20 (other protection level can be customized according to requirements)
Appearance colorRAL7035 (other colors can be customized according to requirements)
Working temperature-10 ℃ ~ 55 ℃
Relative humidity≤95%RH
Altitude≤ 2500 m



GROADA Electronic Load Cabinet 15A/12-R: Precision Testing for Modern Power Systems

TheGROADA Electronic Load Cabinet 15A/12-Ris a state-of-the-art, rack-mounted AC resistive load bank, engineered for rigorous testing and validation of electrical power sources. Designed for professionals in sectors such as data centers, telecommunications, and industrial facilities, this unit ensures that your power systems perform optimally under full-load conditions.


🔧Key Features

  • High-Precision Load Simulation: Offers precise resistive loading up to 15A per phase, enabling accurate simulation of real-world operating conditions.

  • Compact Rack-Mounted Design: Optimized for space-constrained environments, facilitating easy integration into existing setups.

  • User-Friendly Interface: Equipped with intuitive controls and digital displays for straightforward operation and monitoring.

  • Robust Build Quality: Constructed with high-quality materials to ensure durability and long-term reliability.

  • Versatile Application: Suitable for testing a wide range of equipment, including UPS systems, inverters, and backup generators.


⚙️ Technical Specifications

  • Input Voltage: AC 220V

  • Maximum Output Current: 15A per phase

  • Load Type: Resistive

  • Form Factor: Rack-mounted

  • Cooling Method: Forced air

  • Compliance Standards: Meets international safety and performance standards


✅Applications

  • UPS Systems: Validate the performance and capacity of uninterruptible power supplies to ensure reliability during power outages.

  • Inverter Testing: Assess the efficiency and functionality of inverters in renewable energy setups.

  • Generator Load Testing: Simulate load conditions to verify the operational readiness of backup generators.

  • Data Centers: Conduct routine maintenance and performance checks to prevent unexpected downtimes.


📈Industry Insights

According to recent industry analyses, the global load bank market is experiencing significant growth, driven by the increasing demand for reliable power systems across various sectors. Regular load bank testing is essential for identifying potential issues before they lead to system failures, thereby enhancing the overall reliability and efficiency of power infrastructure.


🛠️ Best Practices for Load Bank Testing

To maximize the effectiveness of your load bank testing:

  • Regular Testing: Conduct load bank tests at least annually to ensure equipment reliability.

  • Comprehensive Load Application: Apply loads incrementally up to the maximum rating to thoroughly assess system performance.

  • Safety Protocols: Implement appropriate safety measures, including PPE and proper ventilation, to mitigate risks during testing.

  • Documentation: Maintain detailed records of test results and any anomalies to inform future maintenance and upgrades.


🏆Why Choose the GROADA 15A/12-R?

TheGROADA Electronic Load Cabinet 15A/12-Rstands out in the market for its precision, reliability, and user-centric design. By integrating this load bank into your testing protocols, you ensure that your power systems are thoroughly vetted, reducing the risk of unexpected failures and enhancing operational continuity.


For more information or to request a quote, please contact us:

📧Email:groada@163.com

📞Phone: 0755-23339096

📍Location: Shenzhen, Guangdong, China