Load Bank

GROADA-AC415V-6KW-RLC three-phase load bank

★★★★★
Main Products:
  • AC Load Bank : R / RL / RLC / RCD
  • DC Load Bank : DC5V - 2000V, 0A - 5000A


ModelAC220V-10KVA-RLCAC380V-30KVA-RLCAC380V-60KVA-RLCAC380V-100KVA-RLCAC380V-200KVA-RLCAC380V-300KVA-RLC
Rated powerRLC=10KVARLC=30KVARLC=60KVARLC=100KVARLC=200KVARLC=300KVA
R=10KW;L=10KVA
C=10KVA
R=30KW;L=30KVA;
C=30KVA
R=60KW;L=60KVA;
C=60KVA
R=100KW;L=100KVA;
C=100KVA
R=200KW;L=200KVA;
C=200KVA
R=300KW;L=300KVA;
C=300KVA
Other power can be customized according to requirements
Size (width * depth * height mm)500*750*1400600*850*15001000*1100*15001100*1600*15001500*1800*18002000*2000*2000
Weight120KG380KG580KG880KG1500KG2500KG
Input voltageAC220/230VAC380/400V
Other input voltage can be customized according to requirements
Input current0-45A0-45A0-90A0-150A0-300A0-450A
Minimum loadingR=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=1KW;L=1KVA;
C=1KVA
R=1KW;L=1KVA;
C=1KVA
Other minimum loading power can be customized according to requirements
power factorPF = 0.1~1.0 (other power factor can be customized according to requirements)
Overall accuracy3% (other accuracy requirements can be customized according to requirements)
Control modeLocal manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required)
Remote InterfaceRS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements)
Protection functionEmergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume)
Working power supplyAC220VAC220V/380VAC380V
Display accuracy0.5 level (other explicit precision can be customized according to requirements)
Display parametersVoltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements)
Cold sure waySide air inlet and upper air outlet (other air outlet methods can be customized according to requirements)
Protection levelIP20 (other protection level can be customized according to requirements)
Appearance colorRAL7035 (other colors can be customized according to requirements)
Working temperature-10 ℃ ~ 55 ℃
Relative humidity≤95%RH
Altitude≤ 2500 m



GROADA-AC415V-6KW-RLC Three-Phase Load Bank

Reliable Load Testing for Critical Power Systems

TheGROADA-AC415V-6KW-RLC load bankis designed to provide precise and reliable testing for three-phase AC power systems. This compact yet powerful load bank allows engineers and technicians to simulate real operational loads, ensuring generators, UPS systems, and other critical power equipment operate safely and efficiently under full-load conditions.


Key Features

  • RLC Load Capability: Supports resistive, inductive, and capacitive loads to simulate real-world power consumption patterns.

  • Three-Phase Operation: Ensures accurate testing for industrial and commercial AC systems.

  • High Accuracy: Maintains precise voltage and current control for reliable performance analysis.

  • Durable Construction: Engineered for long-term use in demanding environments.

  • User-Friendly Interface: Simplifies load adjustments and monitoring, even for complex testing scenarios.


Applications

The GROADA-AC415V-6KW-RLC is ideal for a variety of professional environments:

  1. Generator Testing-Verify the reliability and efficiency of emergency and standby generators.

  2. UPS System Verification-Ensure uninterrupted power systems can handle critical loads without failures.

  3. Data Centers-Simulate operational loads to maintain high system availability.

  4. Industrial Facilities-Test electrical systems for stability and resilience.

  5. Renewable Energy Systems-Evaluate integration of renewable sources under variable loads.


Benefits of Load Bank Testing

  • Enhanced System Reliability: Detects potential issues before they cause system failures.

  • Regulatory Compliance: Helps meet safety and performance standards in industrial and commercial installations.

  • Extended Equipment Life: Regular testing reduces wear and prevents premature degradation.

  • Operational Confidence: Provides assurance that backup and primary systems will perform under real load conditions.


Technical Specifications

  • Power Rating: 6 kW

  • Voltage: 415V AC, three-phase

  • Load Types: Resistive (R), Inductive (L), Capacitive (C)

  • Control: Precision manual or automated load adjustment

  • Cooling: Forced air for safe operation under maximum load

  • Dimensions & Weight: Compact design for easy installation and mobility


Why Choose GROADA?

With decades of experience in load bank technology, GROADA ensures products meet the highest standards of quality, safety, and performance.AC415V-6KW-RLC load bankcombines technical excellence with practical usability, making it an essential tool for engineers, data centers, industrial facilities, and power system maintenance teams worldwide.


Conclusion

Investing inGROADA-AC415V-6KW-RLC three-phase load bankguarantees that your critical power systems are tested reliably and efficiently. Ensure safety, compliance, and operational readiness with a solution trusted by professionals across industries.