GROADA-AC600V-25KW-RCD inverter load bank
The GROADA AC600V-25kW RCD Load Bank is a professional testing device designed to simulate real-worl...
| Model | AC220V-10KVA-RLC | AC380V-30KVA-RLC | AC380V-60KVA-RLC | AC380V-100KVA-RLC | AC380V-200KVA-RLC | AC380V-300KVA-RLC |
| Rated power | RLC=10KVA | RLC=30KVA | RLC=60KVA | RLC=100KVA | RLC=200KVA | RLC=300KVA |
| R=10KW;L=10KVA C=10KVA | R=30KW;L=30KVA; C=30KVA | R=60KW;L=60KVA; C=60KVA | R=100KW;L=100KVA; C=100KVA | R=200KW;L=200KVA; C=200KVA | R=300KW;L=300KVA; C=300KVA | |
| Other power can be customized according to requirements | ||||||
| Size (width * depth * height mm) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| Weight | 120KG | 380KG | 580KG | 880KG | 1500KG | 2500KG |
| Input voltage | AC220/230V | AC380/400V | ||||
| Other input voltage can be customized according to requirements | ||||||
| Input current | 0-45A | 0-45A | 0-90A | 0-150A | 0-300A | 0-450A |
| Minimum loading | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=1KW;L=1KVA; C=1KVA | R=1KW;L=1KVA; C=1KVA |
| Other minimum loading power can be customized according to requirements | ||||||
| power factor | PF = 0.1~1.0 (other power factor can be customized according to requirements) | |||||
| Overall accuracy | 3% (other accuracy requirements can be customized according to requirements) | |||||
| Control mode | Local manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required) | |||||
| Remote Interface | RS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements) | |||||
| Protection function | Emergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume) | |||||
| Working power supply | AC220V | AC220V/380V | AC380V | |||
| Display accuracy | 0.5 level (other explicit precision can be customized according to requirements) | |||||
| Display parameters | Voltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements) | |||||
| Cold sure way | Side air inlet and upper air outlet (other air outlet methods can be customized according to requirements) | |||||
| Protection level | IP20 (other protection level can be customized according to requirements) | |||||
| Appearance color | RAL7035 (other colors can be customized according to requirements) | |||||
| Working temperature | -10 ℃ ~ 55 ℃ | |||||
| Relative humidity | ≤95%RH | |||||
| Altitude | ≤ 2500 m | |||||
The GROADA AC800V-851KW-RLC Three-Phase AC Load Bank is a state-of-the-art device designed for rigorous testing of high-voltage power systems. With a capacity of 851 kW, this load bank is engineered to simulate real-world electrical loads, ensuring the reliability and performance of critical power infrastructure.
High Power Capacity: At 851 kW, this load bank is suitable for testing large-scale generators and UPS systems, providing a comprehensive assessment of their performance under full load conditions.
Three-Phase Simulation: The RLC (Resistive-Inductive-Capacitive) design allows for the simulation of complex load profiles, including reactive power, which is essential for testing modern power systems.
Wide Voltage Range: Operating at 800V AC, this load bank is compatible with a variety of high-voltage systems, making it versatile for different testing scenarios.
Advanced Control Interface: Equipped with a user-friendly control panel and digital monitoring, operators can easily set parameters and monitor performance in real-time.
Safety Features: Designed with built-in safety mechanisms, including overcurrent protection and thermal shutdown, to ensure safe operation during testing.
The GROADA AC800V-851KW-RLC Load Bank is ideal for:
Generator Testing: Validating the performance of large-scale generators under full load conditions.
UPS Systems: Ensuring uninterruptible power supplies can handle peak loads without failure.
Power Grid Testing: Simulating various load scenarios to assess the stability and reliability of power grids.
Renewable Energy Systems: Testing the integration of renewable energy sources with existing power infrastructure.
This load bank complies with international standards, ensuring reliable and accurate testing. It meets the requirements set forth by organizations such as the International Electrotechnical Commission (IEC) and the National Electrical Manufacturers Association (NEMA).
Regular load bank testing offers several advantages:
Performance Verification: Confirms that power systems can handle full load conditions without issues.
Preventive Maintenance: Identifies potential problems before they lead to system failures.
Compliance Assurance: Ensures adherence to industry standards and regulations.
Operational Efficiency: Enhances the reliability and longevity of power systems.
The GROADA AC800V-851KW-RLC Three-Phase AC Load Bank is a critical tool for testing and validating high-voltage power systems. Its advanced features and compliance with industry standards make it an indispensable asset for ensuring the reliability and performance of modern power infrastructure.