Load Bank

GROADA-AC480V-200KW-R resistance load bank

★★★★★
Main Products:
  • AC Load Bank : R / RL / RLC / RCD
  • DC Load Bank : DC5V - 2000V, 0A - 5000A


ModelAC220V-6KW-RAC380V-30KW-RAC380V-60KW-RAC380V-100KW-RAC380V-200KW-RAC380V-400KW-RAC380V-500KW-RAC380V-1000KW-R
Rated power0-6KW0-30KW0-60KW0-100KW0-200KW0-400KW0-500KW0-1000KW
Size (width * depth * height mm)480*600*277500*750*1000600*850*1000600*850*1400700*1000*16501100*1400*17001100*1400*18001500*1800*2000
Weight25KG80KG130KG180KG250KG550KG650KG1100KG
Input current0-30A0-45A0-90A0-150A0-300A0-600A0-750A0-1500A
Minimum loading100W100W500W1KW1KW5KW10KW50KW
Other minimum loading power can be customized according to requirements
Input voltageAC220/230VAC380/400V
Other input voltage can be customized according to requirements
PowerPF=1.0
Overall accuracy3% (other accuracy requirements can be customized according to requirements)
Control modeLocal manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required)
Remote InterfaceRS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements)
Protection functionEmergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume)
Working power supplyAC220VAC220V/380VAC380V
Display accuracy0.5 level (other explicit precision can be customized according to requirements
Display parametersVoltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements)
Cold sure wayForward and outSide air inlet and upper air outlet (other air outlet methods can be customized according to requirements)
Protection levelIP20 (other protection level can be customized according to requirements)
Appearance colorRAL7035 (other colors can be customized according to requirements)
Working temperature-10 ℃ ~ 55 ℃
Relative humidity≤95%RH
Altitude≤ 2500 m


GROADA AC480V 200KW-R Resistance Load Bank

Overview

TheGROADA AC480V 200KW-R Resistance Load Bankis a high-performance, industrial-grade testing device designed to accurately simulate electrical loads for generators, UPS systems, and critical power infrastructure. Built for precision, reliability, and ease of use, this load bank ensures the safety, stability, and longevity of power systems in diverse environments, including data centers, hospitals, industrial plants, and renewable energy installations.


Key Features

  • Voltage & Power Capacity: Operates480V ACwith a maximum power rating200 kW, suitable for large-scale generators and UPS systems.

  • Load Type: Pureresistive load, providing aunity power factor (PF = 1)for realistic simulation of electrical load conditions.

  • Cooling System: Equippedforced-air cooling, ensuring stable operation during prolonged testing sessions.

  • Control Interface:Digital control panelwith real-time monitoring, precise load adjustments, and comprehensive data logging.

  • Portability: Modular designeasy transport and installation, suitable for both temporary and permanent setups.

  • Safety Protection: Features overheat, overcurrent, and short-circuit protection mechanisms to prevent system damage.


Applications

1. Generator & UPS Testing

Regular load testing verifies the performance and reliability of backup power systems. The AC480V 200KW-R load bank applies controlled resistive loads to simulate actual operating conditions, helping to identify potential issues like voltage instability, overheating, or underperformance before they lead to system failures.

2. Preventive Maintenance

Lightly loaded generators often face issues such as carbon buildup and wet stacking. This load bank allows full-capacity testing, ensuring generators operate optimally, improving efficiency, and extending equipment life.

3. Renewable Energy Validation

In solar and wind power systems, the load bank tests inverters and power management components under various load conditions. This ensures systems can handle fluctuations in generation and maintain grid stability, an essential requirement for modern renewable energy infrastructure.

4. Critical Infrastructure Testing

Data centers, hospitals, and other critical facilities rely on uninterrupted power supply. Using this load bank, operators can simulate emergency power scenarios, verifying that backup systems perform reliably during outages and maintain critical operations.


Technical Specifications

SpecificationDetails
Input Voltage480V AC
Maximum Power200 kW
Load TypeResistive
Cooling MethodForced Air
ControlDigital Panel with Monitoring
Power Factor1.0
ProtectionOverheat, Overcurrent, Short Circuit
PortabilityModular, Easy Setup

Industry Insights

Theglobal load bank marketis expanding steadily, driven by increasing electricity demand, industrialization, and renewable energy adoption. Market research indicates a CAGR of approximately5% from 2024 to 2030. Load banks are critical tools for validating the performance of generators, UPS systems, and renewable energy installations, helping operators maintain reliability, efficiency, and safety across diverse power systems.


Benefits

  • Enhanced Reliability: Ensures generators and UPS systems function optimally under full load conditions.

  • Extended Equipment Life: Prevents issues from under-loading, such as carbon buildup in generators.

  • Accurate Simulation: Provides realistic testing environments for both AC and renewable energy systems.

  • Operational Safety: Advanced protection features reduce risks during testing.

  • Versatility: Suitable for industrial, commercial, and renewable energy applications.


Conclusion

TheGROADA AC480V 200KW-R Resistance Load Bankis an indispensable tool for maintaining the performance, safety, and longevity of critical power systems. By delivering precise, controlled load testing, it enables engineers and facility managers to conduct preventive maintenance, validate renewable energy systems, and ensure uninterrupted operation of essential infrastructure.

Investing in a high-quality load bank like the AC480V 200KW-R ensures reliable power supply, optimized system performance, and peace of mind for facilities that cannot afford downtime.