GROADA-AC600V-25KW-RCD inverter load bank
The GROADA AC600V-25kW RCD Load Bank is a professional testing device designed to simulate real-worl...
| Model | AC220V-6KW-R | AC380V-30KW-R | AC380V-60KW-R | AC380V-100KW-R | AC380V-200KW-R | AC380V-400KW-R | AC380V-500KW-R | AC380V-1000KW-R |
| Rated power | 0-6KW | 0-30KW | 0-60KW | 0-100KW | 0-200KW | 0-400KW | 0-500KW | 0-1000KW |
| Size (width * depth * height mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Weight | 25KG | 80KG | 130KG | 180KG | 250KG | 550KG | 650KG | 1100KG |
| Input current | 0-30A | 0-45A | 0-90A | 0-150A | 0-300A | 0-600A | 0-750A | 0-1500A |
| Minimum loading | 100W | 100W | 500W | 1KW | 1KW | 5KW | 10KW | 50KW |
| Other minimum loading power can be customized according to requirements | ||||||||
| Input voltage | AC220/230V | AC380/400V | ||||||
| Other input voltage can be customized according to requirements | ||||||||
| Power | PF=1.0 | |||||||
| Overall accuracy | 3% (other accuracy requirements can be customized according to requirements) | |||||||
| Control mode | Local manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required) | |||||||
| Remote Interface | RS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements) | |||||||
| Protection function | Emergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume) | |||||||
| Working power supply | AC220V | AC220V/380V | AC380V | |||||
| Display accuracy | 0.5 level (other explicit precision can be customized according to requirements | |||||||
| Display parameters | Voltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements) | |||||||
| Cold sure way | Forward and out | Side air inlet and upper air outlet (other air outlet methods can be customized according to requirements) | ||||||
| Protection level | IP20 (other protection level can be customized according to requirements) | |||||||
| Appearance color | RAL7035 (other colors can be customized according to requirements) | |||||||
| Working temperature | -10 ℃ ~ 55 ℃ | |||||||
| Relative humidity | ≤95%RH | |||||||
| Altitude | ≤ 2500 m | |||||||
TheGROADA AC480V 200KW-R Resistance Load Bankis a high-performance, industrial-grade testing device designed to accurately simulate electrical loads for generators, UPS systems, and critical power infrastructure. Built for precision, reliability, and ease of use, this load bank ensures the safety, stability, and longevity of power systems in diverse environments, including data centers, hospitals, industrial plants, and renewable energy installations.
Voltage & Power Capacity: Operates480V ACwith a maximum power rating200 kW, suitable for large-scale generators and UPS systems.
Load Type: Pureresistive load, providing aunity power factor (PF = 1)for realistic simulation of electrical load conditions.
Cooling System: Equippedforced-air cooling, ensuring stable operation during prolonged testing sessions.
Control Interface:Digital control panelwith real-time monitoring, precise load adjustments, and comprehensive data logging.
Portability: Modular designeasy transport and installation, suitable for both temporary and permanent setups.
Safety Protection: Features overheat, overcurrent, and short-circuit protection mechanisms to prevent system damage.
Regular load testing verifies the performance and reliability of backup power systems. The AC480V 200KW-R load bank applies controlled resistive loads to simulate actual operating conditions, helping to identify potential issues like voltage instability, overheating, or underperformance before they lead to system failures.
Lightly loaded generators often face issues such as carbon buildup and wet stacking. This load bank allows full-capacity testing, ensuring generators operate optimally, improving efficiency, and extending equipment life.
In solar and wind power systems, the load bank tests inverters and power management components under various load conditions. This ensures systems can handle fluctuations in generation and maintain grid stability, an essential requirement for modern renewable energy infrastructure.
Data centers, hospitals, and other critical facilities rely on uninterrupted power supply. Using this load bank, operators can simulate emergency power scenarios, verifying that backup systems perform reliably during outages and maintain critical operations.
| Specification | Details |
|---|---|
| Input Voltage | 480V AC |
| Maximum Power | 200 kW |
| Load Type | Resistive |
| Cooling Method | Forced Air |
| Control | Digital Panel with Monitoring |
| Power Factor | 1.0 |
| Protection | Overheat, Overcurrent, Short Circuit |
| Portability | Modular, Easy Setup |
Theglobal load bank marketis expanding steadily, driven by increasing electricity demand, industrialization, and renewable energy adoption. Market research indicates a CAGR of approximately5% from 2024 to 2030. Load banks are critical tools for validating the performance of generators, UPS systems, and renewable energy installations, helping operators maintain reliability, efficiency, and safety across diverse power systems.
Enhanced Reliability: Ensures generators and UPS systems function optimally under full load conditions.
Extended Equipment Life: Prevents issues from under-loading, such as carbon buildup in generators.
Accurate Simulation: Provides realistic testing environments for both AC and renewable energy systems.
Operational Safety: Advanced protection features reduce risks during testing.
Versatility: Suitable for industrial, commercial, and renewable energy applications.
TheGROADA AC480V 200KW-R Resistance Load Bankis an indispensable tool for maintaining the performance, safety, and longevity of critical power systems. By delivering precise, controlled load testing, it enables engineers and facility managers to conduct preventive maintenance, validate renewable energy systems, and ensure uninterrupted operation of essential infrastructure.
Investing in a high-quality load bank like the AC480V 200KW-R ensures reliable power supply, optimized system performance, and peace of mind for facilities that cannot afford downtime.