Load Bank

GROADA-AC415V/240V-3KVR-L AC load bank

★★★★★
Main Products:
  • AC Load Bank : R / RL / RLC / RCD
  • DC Load Bank : DC5V - 2000V, 0A - 5000A


ModelAC220V-6KW-RAC380V-30KW-RAC380V-60KW-RAC380V-100KW-RAC380V-200KW-RAC380V-400KW-RAC380V-500KW-RAC380V-1000KW-R
Rated power0-6KW0-30KW0-60KW0-100KW0-200KW0-400KW0-500KW0-1000KW
Size (width * depth * height mm)480*600*277500*750*1000600*850*1000600*850*1400700*1000*16501100*1400*17001100*1400*18001500*1800*2000
Weight25KG80KG130KG180KG250KG550KG650KG1100KG
Input current0-30A0-45A0-90A0-150A0-300A0-600A0-750A0-1500A
Minimum loading100W100W500W1KW1KW5KW10KW50KW
Other minimum loading power can be customized according to requirements
Input voltageAC220/230VAC380/400V
Other input voltage can be customized according to requirements
PowerPF=1.0
Overall accuracy3% (other accuracy requirements can be customized according to requirements)
Control modeLocal manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required)
Remote InterfaceRS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements)
Protection functionEmergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume)
Working power supplyAC220VAC220V/380VAC380V
Display accuracy0.5 level (other explicit precision can be customized according to requirements
Display parametersVoltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements)
Cold sure wayForward and outSide air inlet and upper air outlet (other air outlet methods can be customized according to requirements)
Protection levelIP20 (other protection level can be customized according to requirements)
Appearance colorRAL7035 (other colors can be customized according to requirements)
Working temperature-10 ℃ ~ 55 ℃
Relative humidity≤95%RH
Altitude≤ 2500 m



GROADA AC415V/240V-3KVR-L Load Bank: Comprehensive Overview

The GROADA AC415V/240V-3KVR-L Load Bank is a high-performance, resistive-inductive (R-L) three-phase testing device designed to simulate real-world electrical loads. It is engineered for rigorous testing and maintenance of power systems, ensuring their reliability and efficiency in critical applications.


🔧Key Specifications

  • Model: GROADA AC415V/240V-3KVR-L

  • Type: Resistive-Inductive (R-L) Load Bank

  • Voltage: 415V / 240V

  • Phase: Three-Phase

  • Power Rating: 3 kVA


🛠️ Applications

This load bank is ideal for testing and maintaining various power systems, including:

  • Generators: Ensures that generators can handle full-rated loads, preventing issues like wet stacking and verifying performance under load conditions.

  • Uninterruptible Power Supplies (UPS): Validates the capacity and reliability of UPS systems, ensuring they can provide continuous power during outages.

  • Renewable Energy Systems: Simulates electrical loads to test the performance of solar and wind power systems, aiding in grid integration and stability.

  • Inverter Systems: Assesses the functionality of inverters, crucial for converting DC to AC power in renewable energy setups.


✅Benefits

  • Enhanced Reliability: Regular load testing identifies potential issues before they lead to system failures, ensuring continuous operation.

  • Compliance Assurance: Meets industry standards and regulations, including those set by the National Fire Protection Association (NFPA) for emergency power systems.

  • Operational Efficiency: Burns off carbon deposits and prevents wet stacking, leading to improved engine performance and longevity.

  • Cost Savings: Early detection of faults can prevent costly repairs and downtime, offering significant long-term savings.


📊Industry Insights

The global load bank market is experiencing steady growth, driven by increasing demand for electricity and expanding industrial activities. According to market reports, the load bank market is projected to grow at a compound annual growth rate (CAGR) of 5.1% from 2024 to 2030.

Load banks play a critical role in various sectors, including data centers, hospitals, and manufacturing facilities, by ensuring the reliability and performance of backup power systems. They are essential for validating the capacity and functionality of power sources, providing a controlled environment to simulate real-world electrical loads


⚙️ Technical Features

  • Adjustable Load Levels: Allows precise simulation of varying load conditions, providing accurate testing scenarios.

  • User-Friendly Interface: Equipped with intuitive controls for easy operation and monitoring.

  • Robust Construction: Designed to withstand harsh environments, ensuring durability and longevity.

  • Safety Mechanisms: Incorporates protective features to prevent damage and ensure operator safety during testing procedures.


📝Conclusion

The GROADA AC415V/240V-3KVR-L Load Bank is a versatile and reliable tool for testing and maintaining power systems. Its advanced features and robust design make it an essential component for ensuring the performance and longevity of critical electrical infrastructure. By incorporating this load bank into your maintenance regimen, you can enhance system reliability, comply with industry standards, and achieve significant cost savings.


Contact Information

  • Email: groada@163.com

  • Phone: 86 0755-23339096

  • Location: Shenzhen, Guangdong, China

Our Product