Load Bank

GROADA-AC220V-15KW-RLC three-phase load bank

★★★★★
Main Products:
  • AC Load Bank : R / RL / RLC / RCD
  • DC Load Bank : DC5V - 2000V, 0A - 5000A


ModelAC220V-10KVA-RLCAC380V-30KVA-RLCAC380V-60KVA-RLCAC380V-100KVA-RLCAC380V-200KVA-RLCAC380V-300KVA-RLC
Rated powerRLC=10KVARLC=30KVARLC=60KVARLC=100KVARLC=200KVARLC=300KVA
R=10KW;L=10KVA
C=10KVA
R=30KW;L=30KVA;
C=30KVA
R=60KW;L=60KVA;
C=60KVA
R=100KW;L=100KVA;
C=100KVA
R=200KW;L=200KVA;
C=200KVA
R=300KW;L=300KVA;
C=300KVA
Other power can be customized according to requirements
Size (width * depth * height mm)500*750*1400600*850*15001000*1100*15001100*1600*15001500*1800*18002000*2000*2000
Weight120KG380KG580KG880KG1500KG2500KG
Input voltageAC220/230VAC380/400V
Other input voltage can be customized according to requirements
Input current0-45A0-45A0-90A0-150A0-300A0-450A
Minimum loadingR=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=1KW;L=1KVA;
C=1KVA
R=1KW;L=1KVA;
C=1KVA
Other minimum loading power can be customized according to requirements
power factorPF = 0.1~1.0 (other power factor can be customized according to requirements)
Overall accuracy3% (other accuracy requirements can be customized according to requirements)
Control modeLocal manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required)
Remote InterfaceRS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements)
Protection functionEmergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume)
Working power supplyAC220VAC220V/380VAC380V
Display accuracy0.5 level (other explicit precision can be customized according to requirements)
Display parametersVoltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements)
Cold sure waySide air inlet and upper air outlet (other air outlet methods can be customized according to requirements)
Protection levelIP20 (other protection level can be customized according to requirements)
Appearance colorRAL7035 (other colors can be customized according to requirements)
Working temperature-10 ℃ ~ 55 ℃
Relative humidity≤95%RH
Altitude≤ 2500 m



GROADA AC220V-15KW-RLC Three-Phase Load Bank: Comprehensive Overview


🔌Introduction

In today's rapidly evolving energy landscape, ensuring the reliability and efficiency of power systems is paramount. The GROADA AC220V-15KW-RLC three-phase load bank emerges as a pivotal tool in this endeavor, offering advanced testing capabilities to simulate real-world electrical loads. Manufactured by GROADA, a reputable company based in Shenzhen, Guangdong, China, this load bank is engineered to validate the performance and capacity of various power sources under controlled conditions.


⚙️ Technical Specifications

  • Model: AC220V-15KW-RLC

  • Power Rating: 15KW

  • Voltage: 220V AC

  • Phase Configuration: Three-phase

  • Load Type: Resistive-Inductive-Capacitive (RLC)

  • Cooling Method: Forced air cooling

  • Control Interface: Digital display with remote control capabilities

  • Safety Features: Overload protection, short circuit protection, and temperature monitoring


🛠️ Applications

The GROADA AC220V-15KW-RLC load bank is versatile and can be employed in various scenarios, including:

  • Generator Testing: Simulate operational loads to assess performance and fuel consumption.

  • Uninterruptible Power Supply (UPS) Systems: Evaluate battery capacity and system integrity.

  • Renewable Energy Systems: Test solar and wind power installations under grid conditions.

  • Data Centers: Ensure backup power systems can handle peak loads.

  • Industrial Facilities: Validate power distribution systems for reliability.


✅Benefits

  1. Enhanced System Reliability: Regular testing with the GROADA load bank helps identify potential issues before they lead to system failures, ensuring continuous operation of critical infrastructure.

  2. Extended Equipment Lifespan: By operating power systems at full capacity during tests, carbon deposits and other residues are burned off, reducing wear and tear and prolonging the life of equipment.

  3. Compliance with Industry Standards: Load bank testing ensures that power systems meet regulatory requirements and performance standards, which is crucial for industries with stringent compliance needs.

  4. Cost Savings: Identifying and addressing potential issues early can prevent costly repairs and downtime, leading to significant cost savings over time.


📊Industry Insights

According to industry standards, load bank testing is essential for verifying the performance and capacity of power systems. It provides a controlled environment to simulate real-world operating conditions, allowing for comprehensive assessment and validation. This practice is widely adopted across various sectors, including telecommunications, healthcare, and manufacturing, to ensure the reliability and efficiency of power systems.


🧠Conclusion

The GROADA AC220V-15KW-RLC three-phase load bank stands out as a reliable and efficient solution for testing and validating power systems. Its advanced features and capabilities make it suitable for a wide range of applications, ensuring that power systems operate efficiently and reliably. By incorporating this load bank into regular maintenance and testing routines, organizations can enhance the performance, longevity, and compliance of their power systems.


📞Contact Information

  • Email:groada@163.com

  • Phone: 0755-23339096

  • Location: Shenzhen, Guangdong, China


Our Product