GROADA-AC600V-25KW-RCD inverter load bank
The GROADA AC600V-25kW RCD Load Bank is a professional testing device designed to simulate real-worl...
| Model | AC220V-10KVA-RLC | AC380V-30KVA-RLC | AC380V-60KVA-RLC | AC380V-100KVA-RLC | AC380V-200KVA-RLC | AC380V-300KVA-RLC |
| Rated power | RLC=10KVA | RLC=30KVA | RLC=60KVA | RLC=100KVA | RLC=200KVA | RLC=300KVA |
| R=10KW;L=10KVA C=10KVA | R=30KW;L=30KVA; C=30KVA | R=60KW;L=60KVA; C=60KVA | R=100KW;L=100KVA; C=100KVA | R=200KW;L=200KVA; C=200KVA | R=300KW;L=300KVA; C=300KVA | |
| Other power can be customized according to requirements | ||||||
| Size (width * depth * height mm) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| Weight | 120KG | 380KG | 580KG | 880KG | 1500KG | 2500KG |
| Input voltage | AC220/230V | AC380/400V | ||||
| Other input voltage can be customized according to requirements | ||||||
| Input current | 0-45A | 0-45A | 0-90A | 0-150A | 0-300A | 0-450A |
| Minimum loading | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=1KW;L=1KVA; C=1KVA | R=1KW;L=1KVA; C=1KVA |
| Other minimum loading power can be customized according to requirements | ||||||
| power factor | PF = 0.1~1.0 (other power factor can be customized according to requirements) | |||||
| Overall accuracy | 3% (other accuracy requirements can be customized according to requirements) | |||||
| Control mode | Local manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required) | |||||
| Remote Interface | RS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements) | |||||
| Protection function | Emergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume) | |||||
| Working power supply | AC220V | AC220V/380V | AC380V | |||
| Display accuracy | 0.5 level (other explicit precision can be customized according to requirements) | |||||
| Display parameters | Voltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements) | |||||
| Cold sure way | Side air inlet and upper air outlet (other air outlet methods can be customized according to requirements) | |||||
| Protection level | IP20 (other protection level can be customized according to requirements) | |||||
| Appearance color | RAL7035 (other colors can be customized according to requirements) | |||||
| Working temperature | -10 ℃ ~ 55 ℃ | |||||
| Relative humidity | ≤95%RH | |||||
| Altitude | ≤ 2500 m | |||||
In today's rapidly evolving energy landscape, ensuring the reliability and efficiency of power systems is paramount. The GROADA AC220V-15KW-RLC three-phase load bank emerges as a pivotal tool in this endeavor, offering advanced testing capabilities to simulate real-world electrical loads. Manufactured by GROADA, a reputable company based in Shenzhen, Guangdong, China, this load bank is engineered to validate the performance and capacity of various power sources under controlled conditions.
Model: AC220V-15KW-RLC
Power Rating: 15KW
Voltage: 220V AC
Phase Configuration: Three-phase
Load Type: Resistive-Inductive-Capacitive (RLC)
Cooling Method: Forced air cooling
Control Interface: Digital display with remote control capabilities
Safety Features: Overload protection, short circuit protection, and temperature monitoring
The GROADA AC220V-15KW-RLC load bank is versatile and can be employed in various scenarios, including:
Generator Testing: Simulate operational loads to assess performance and fuel consumption.
Uninterruptible Power Supply (UPS) Systems: Evaluate battery capacity and system integrity.
Renewable Energy Systems: Test solar and wind power installations under grid conditions.
Data Centers: Ensure backup power systems can handle peak loads.
Industrial Facilities: Validate power distribution systems for reliability.
Enhanced System Reliability: Regular testing with the GROADA load bank helps identify potential issues before they lead to system failures, ensuring continuous operation of critical infrastructure.
Extended Equipment Lifespan: By operating power systems at full capacity during tests, carbon deposits and other residues are burned off, reducing wear and tear and prolonging the life of equipment.
Compliance with Industry Standards: Load bank testing ensures that power systems meet regulatory requirements and performance standards, which is crucial for industries with stringent compliance needs.
Cost Savings: Identifying and addressing potential issues early can prevent costly repairs and downtime, leading to significant cost savings over time.
According to industry standards, load bank testing is essential for verifying the performance and capacity of power systems. It provides a controlled environment to simulate real-world operating conditions, allowing for comprehensive assessment and validation. This practice is widely adopted across various sectors, including telecommunications, healthcare, and manufacturing, to ensure the reliability and efficiency of power systems.
The GROADA AC220V-15KW-RLC three-phase load bank stands out as a reliable and efficient solution for testing and validating power systems. Its advanced features and capabilities make it suitable for a wide range of applications, ensuring that power systems operate efficiently and reliably. By incorporating this load bank into regular maintenance and testing routines, organizations can enhance the performance, longevity, and compliance of their power systems.