Industrial Testing Equipment
GROADA-AC380V-30KW-RCD inverter load bank
Explore product details and technical information, or send us your requirements for application guidance and a quotation.
Request Product Information
Tell us what you need. Our team can follow up with product details and quotation information.
Product Overview & Technical Specifications
| Model | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380V-30KW-RCD | AC380V-50KW-RCD | AC380V-60KW-RCD | AC380V-100KW-RCD | AC380V-200KW-RCD |
| Rated power | R=5KW | R=10KW | R=15KW | R=20KW | R=30KW | R=50KW | R=60KW | R=100KW | R=200KW |
| RCD=5KVA | RCD=10KVA | RCD=15KVA | RCD=20KVA | RCD=30KVA | RCD=50KVA | RCD=60KVA | RCD=100KVA | RCD=200KVA | |
| Input current | 0-22A | 0-45A | 0-45A | 0-90A | 0-45A | 0-300A | 0-450A | 0-600A | 0-750A |
| Size (width * depth * height mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Weight | 50KG | 80KG | 100KG | 130KG | 200KG | 300KG | 350KG | 450KG | 550KG |
| Input voltage | AC220/230V | AC380/400V | |||||||
| Other input voltage can be customized according to requirements | |||||||||
| Minimum loading | 100W | 100W | 100W | 100W | 100W | 1KW | 1KW | 1KW | 1KW |
| Other minimum loading power can be customized according to requirements | |||||||||
| Overall accuracy | 3% (other accuracy requirements can be customized according to requirements) | ||||||||
| power factor | PF=0.6~1.0 | ||||||||
| peak coefficient | 2 to 3 | ||||||||
| Control mode | Local manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required) | ||||||||
| Remote Interface | RS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements) | ||||||||
| Protection function | Emergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume) | ||||||||
| Working power supply | AC220V | AC220V/AC380V | |||||||
| Display accuracy | 0.5 level (other explicit precision can be customized according to requirements) | ||||||||
| Display parameters | Voltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements) | ||||||||
| Cold sure way | Side air inlet and upper air outlet (other air outlet methods can be customized according to requirements) | ||||||||
| Protection level | IP20 (other protection level can be customized according to requirements) | ||||||||
| Appearance color | RAL7035 (other colors can be customized according to requirements) | ||||||||
| Working temperature | -10 ℃ ~ 55 ℃ | ||||||||
| Relative humidity | ≤95%RH | ||||||||
| Altitude | ≤ 2500 m | ||||||||
GROADA-AC380V-30KW-RCD Inverter Load Bank: Comprehensive Overview for Optimal Generator Performance
Introduction
The GROADA-AC380V-30KW-RCD inverter load bank is a cutting-edge device engineered to simulate real-world electrical loads, ensuring the reliability and efficiency of power systems, particularly in inverter-based setups. This load bank is indispensable for industries where uninterrupted power supply is critical, such as data centers, hospitals, and industrial facilities.
Key Features and Specifications
-
Voltage Compatibility: Designed for 380V AC systems, making it suitable for a wide range of industrial applications.
-
Power Capacity: Offers a 30kW load capacity, allowing for comprehensive testing of medium to large-scale generators and inverters.
-
RCD Functionality: Equipped with Residual Current Device (RCD) protection, ensuring safety by detecting and interrupting leakage currents, thereby preventing potential electrical hazards.
-
Inverter Testing Capability: Specifically tailored to test inverter-based power systems, ensuring they can handle varying loads without compromising performance.
Importance of Load Bank Testing
Load bank testing plays a pivotal role in validating the performance of power systems under simulated operational conditions. By applying artificial loads, this testing method helps in:
-
Verifying Full Load Operation: Ensures that generators and inverters can operate at their rated capacity without issues.
-
Identifying Potential Failures: Detects weaknesses in components that may not be apparent during routine operations.
-
Preventing Wet Stacking: Regular testing helps in avoiding the accumulation of unburned fuel in diesel engines, a common issue when engines run under low loads.
-
Enhancing Fuel Efficiency: By ensuring optimal operation, load bank testing contributes to better fuel consumption rates.
According to industry standards, such as the NFPA 110, load bank testing should be conducted at least annually, or more frequently depending on the criticality of the application.
Applications
The GROADA-AC380V-30KW-RCD inverter load bank is ideal for:
-
Data Centers: Ensuring that backup power systems can handle the high and fluctuating loads typical in data processing environments.
-
Healthcare Facilities: Verifying that emergency power systems are capable of supporting life-saving equipment during power outages.
-
Industrial Operations: Testing generators and inverters that power critical machinery, preventing unexpected downtime.
-
Renewable Energy Systems: Evaluating the performance of inverter-based setups in solar or wind energy applications.
Benefits of Using the GROADA-AC380V-30KW-RCD Inverter Load Bank
-
Enhanced Reliability: Regular testing ensures that power systems are always ready to perform under load.
-
Safety Assurance: The integrated RCD protection minimizes the risk of electrical shocks and fires.
-
Cost Savings: By identifying potential issues early, costly repairs and unplanned downtime can be avoided.
-
Compliance Adherence: Helps in meeting industry standards and regulations, ensuring operational continuity.
Conclusion
Incorporating the GROADA-AC380V-30KW-RCD inverter load bank into your maintenance regimen is a proactive approach to ensuring the reliability and efficiency of your power systems. By simulating real-world loads, it provides valuable insights into system performance, enabling timely interventions and enhancing overall operational resilience.
For industries where power reliability is paramount, investing in such advanced load testing equipment is not just a precaution; it's a necessity.