RL Load Bank

GROADA-AC380V--600kw-RL Generator resistance inductive load bank

★★★★★
Main Products:
  • AC Load Bank : R / RL / RLC / RCD
  • DC Load Bank : DC5V - 2000V, 0A - 5000A


ModelAC220V-10KVA-RLAC380V-30KVA-RLAC380V-60KVA-RLAC380V-100KVA-RLAC380V-300KVA-RLAC380V-500KVA-RLAC380V-1000KVA-RL
Rated powerRL=10KVARL=30KVARL=60KVARL=100KVARL=300KVARL=500KVARL=1000KVA
R=10KW;L=6KVAR=30KW;L=18KVAR=60KW;L=36KVAR=100KW;L=60KVAR=300KW;L=180KVAR=500KW;L=300KVAR=1000KW;L=600KVA
Input current0-45A0-45A0-90A0-150A0-450A0-750A0-1500A
Size (width * depth * height mm)480*600*277480*600*360500*750*1000600*850*1000700*1000*16501100*1400*17001100*1500*1900
Weight25KG40KG80KG130KG250KG550KG750KG
Minimum loading100W100W100W500W1KW5KW10KW
Other minimum loading power can be customized according to requirements
Input voltageAC220/230VAC380/400V
Other input voltage can be customized according to requirements
power factorPF = 0.8/1.0 (other power factor can be customized according to requirements)
Overall accuracy3% (other accuracy requirements can be customized according to requirements)
Control modeLocal manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required)
Remote InterfaceRS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements)
Protection functionEmergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume)
Working power supplyAC220VAC220V/380VAC380V
Display accuracy0.5 level (other explicit precision can be customized according to requirements)
Display parametersVoltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements)
Cold sure waySide air inlet and upper air outlet (other air outlet methods can be customized according to requirements)
Protection levelIP20 (other protection level can be customized according to requirements)
Appearance colorRAL7035 (other colors can be customized according to requirements)
Working temperature-10 ℃ ~ 55 ℃
Relative humidity≤95%RH
Altitude≤ 2500 m



GROADA-AC380V–600kW-RL Generator Resistance-Inductive Load Bank

Ensure your power systems are reliable, safe, and fully operational with the GROADA-AC380V–600kW-RL Load Bank. Designed for high-capacity generator testing, this resistance-inductive (RL) load bank delivers precise, robust, and versatile performance for industrial, commercial, and critical power applications.


Key Specifications

  • Model: GROADA-AC380V–600kW-RL

  • Type: Resistance-Inductive (RL) Load Bank

  • Voltage: 380V AC

  • Power Capacity: 600 kW

  • Phase: Three-phase

  • Application: Generator testing, commissioning, maintenance


Product Highlights

High Power Handling

With a capacity of 600 kW, the GROADA-AC380V–600kW-RL load bank simulates real-world generator load conditions, ensuring accurate testing and validation of power systems under full operational stress.

Versatile Resistance-Inductive Load

The RL configuration allows simultaneous testing of resistive and inductive loads. This ensures a comprehensive evaluation of generator performance, capturing both steady-state and reactive load characteristics.

Advanced Control System

Equipped with a sophisticated and user-friendly control interface, operators can monitor, adjust, and record load parameters with high accuracy. This enhances operational safety and efficiency while providing real-time performance feedback.

Durable and Reliable

Constructed with industrial-grade components, the load bank is built to endure long-term, high-intensity use. Its robust design allows deployment in indoor and outdoor environments without compromising reliability.


Applications

  • Generator Commissioning: Validate new generator performance under actual operational conditions.

  • Preventive Maintenance: Identify issues proactively, preventing downtime and costly repairs.

  • Regulatory Compliance: Ensure compliance with standards like NFPA 110, essential for emergency power systems.

  • Training and Simulation: Provide realistic scenarios for staff training, enhancing preparedness for emergency situations.


Industry Insights

The global load bank market is projected to grow steadily, driven by increasing demand for reliable power systems across industries such as data centers, healthcare, and manufacturing. Load banks like the GROADA-AC380V–600kW-RL are critical for ensuring generator reliability and operational safety, with the market estimated to reach over USD 387 million by 2032.


Benefits of Choosing GROADA-AC380V–600kW-RL

  • Enhanced Reliability: Guarantees generators perform optimally during peak demand and emergencies.

  • Cost Efficiency: Early identification of potential faults reduces repair costs and operational downtime.

  • Regulatory Assurance: Meets industry standards to ensure uninterrupted power supply readiness.

  • Operational Confidence: Peace of mind knowing that critical systems are protected by thoroughly tested backup power.


Why Invest in GROADA Load Banks?

Investing in the GROADA-AC380V–600kW-RL Load Bank ensures comprehensive generator testing, prolongs equipment life, reduces maintenance costs, and strengthens operational reliability. It is the ultimate solution for industries that cannot afford power interruptions.


Contact Information

  • Email: groada@163.com

  • Phone: +86 0755-23339096

  • Location: Shenzhen, Guangdong, China


GROADA-AC380V–600kW-RL is your trusted partner for generator testing and preventive maintenance, offering high precision, reliability, and industry compliance in one powerful solution.

Our Product