| Rated power | 0-6KW | 0-30KW | 0-60KW | 0-100KW | 0-200KW | 0-400KW | 0-500KW | 0-1000KW |
| Size (width * depth * height mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Weight | 25KG | 80KG | 130KG | 180KG | 250KG | 550KG | 650KG | 1100KG |
| Input current | 0-30A | 0-45A | 0-90A | 0-150A | 0-300A | 0-600A | 0-750A | 0-1500A |
| Power | PF=1.0 | |||||||
| Overall accuracy | 3% (other accuracy requirements can be customized according to requirements) | |||||||
| Control mode | Local manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required) | |||||||
| Remote Interface | RS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements) | |||||||
| Protection function | Emergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume) | |||||||
| Display accuracy | 0.5 level (other explicit precision can be customized according to requirements | |||||||
| Display parameters | Voltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements) | |||||||
| Cold sure way | Forward and out | Side air inlet and upper air outlet (other air outlet methods can be customized according to requirements) | ||||||
| Protection level | IP20 (other protection level can be customized according to requirements) | |||||||
| Appearance color | RAL7035 (other colors can be customized according to requirements) | |||||||
| Working temperature | -10 ℃ ~ 55 ℃ | |||||||
| Relative humidity | ≤95%RH | |||||||
| Altitude | ≤ 2500 m | |||||||
GROADA-AC380V-50KW-R Charging Pile Load Bank – High-Performance EVSE Testing Solution
Introduction
The GROADA-AC380V-50KW-R Charging Pile Load Bank is a professional-grade testing device designed to simulate real-world conditions for electric vehicle charging stations (EVSE). It provides reliable, precise, and safe load simulation, making it indispensable for manufacturers, testing labs, and service providers who aim to ensure optimal performance, safety, and compliance of EV chargers.
As EV adoption grows globally, rigorous testing of charging infrastructure is critical. This load bank enables users to validate chargers under varying loads and operational scenarios, helping prevent failures and maintain high standards.
Product Overview
-
Model: GROADA-AC380V-50KW-R
-
Voltage: AC 380V
-
Power Capacity: 50 kW
-
Type: Resistive-Inductive (RL) three-phase load bank
The device simulates the actual load conditions of high-power EV charging piles, supporting comprehensive testing for voltage, current, power factor, and harmonic distortion. Its robust construction ensures reliability during extended operation, making it suitable for rigorous industrial use.
Key Features
-
High Power Simulation
With a 50 kW capacity, it can emulate the load profile of large EV charging stations, allowing stress testing of chargers under peak conditions. -
Adjustable Load Settings
Users can precisely control load parameters to mimic different operating scenarios, facilitating thorough performance evaluations. -
Advanced Monitoring & Safety
Integrated digital display and monitoring system allow real-time observation of voltage, current, and power factor, with safety protections to prevent overload, short circuit, or overheating. -
Compliance with Global Standards
Designed to meet international standards such as IEC 61851-1, ensuring safe and compliant testing of EVSE devices worldwide. -
Durable and Reliable Design
Constructed with high-quality resistive and inductive components, the unit guarantees stability and long operational life, even under continuous testing.
Applications
-
EV Charger Manufacturers: Validate performance and compliance before deployment.
-
Testing Laboratories: Conduct standardized testing for certification and safety verification.
-
Service and Maintenance Providers: Assess functionality and ensure reliable operation of installed charging infrastructure.
-
Regulatory Authorities: Facilitate compliance inspections and certification processes.
Industry Significance
As EV infrastructure rapidly expands, ensuring chargers can reliably handle varying loads is paramount. The GROADA-AC380V-50KW-R load bank enables precise simulation and testing, helping avoid downtime, enhance charger longevity, and maintain user safety. It supports the global push for dependable EV charging networks while reducing operational risks for manufacturers and operators.
Conclusion
The GROADA-AC380V-50KW-R Charging Pile Load Bank is a versatile, high-performance testing solution designed for the EV industry. Its combination of precision, safety, and reliability makes it a critical tool for manufacturers, labs, and service providers dedicated to high-quality EVSE deployment.
Contact Information
-
Email: groada@163.com
-
Phone: +86 755 2333 9096
-
Location: Shenzhen, Guangdong, China