EVSE Load Bank

GROADA-AC220V-60KW-R charging pile load bank

★★★★★
Main Products:
  • AC Load Bank : R / RL / RLC / RCD
  • DC Load Bank : DC5V - 2000V, 0A - 5000A


Rated power0-6KW0-30KW0-60KW0-100KW0-200KW0-400KW0-500KW0-1000KW
Size (width * depth * height mm)480*600*277500*750*1000600*850*1000600*850*1400700*1000*16501100*1400*17001100*1400*18001500*1800*2000
Weight25KG80KG130KG180KG250KG550KG650KG1100KG
Input current0-30A0-45A0-90A0-150A0-300A0-600A0-750A0-1500A
PowerPF=1.0
Overall accuracy3% (other accuracy requirements can be customized according to requirements)
Control modeLocal manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required)
Remote InterfaceRS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements)
Protection functionEmergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume)
Display accuracy0.5 level (other explicit precision can be customized according to requirements
Display parametersVoltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements)
Cold sure wayForward and outSide air inlet and upper air outlet (other air outlet methods can be customized according to requirements)
Protection levelIP20 (other protection level can be customized according to requirements)
Appearance colorRAL7035 (other colors can be customized according to requirements)
Working temperature-10 ℃ ~ 55 ℃
Relative humidity≤95%RH
Altitude≤ 2500 m



GROADA-AC220V-60KW-R Charging Pile Load Bank: A Comprehensive Solution for EV Charging Infrastructure Testing


Introduction

As the global adoption of electric vehicles (EVs) accelerates, the demand for reliable and efficient EV charging infrastructure intensifies. Ensuring the performance and safety of charging stations is paramount. The GROADA-AC220V-60KW-R Charging Pile Load Bank emerges as a pivotal tool in this endeavor, offering a robust solution for simulating real-world load conditions and verifying the operational integrity of EV charging equipment.


Technical Specifications

  • Rated Power: 60 kW

  • Input Voltage: AC 220V, 50Hz

  • Load Type: Resistive

  • Load Adjustment: Manual and remote control options

  • Protection Features: Overload, over-temperature, and short-circuit protection

  • Display: High-precision LCD meters for voltage, current, power, and power factor

  • Construction: Durable steel enclosure with IP67 protection rating

  • Cooling System: Efficient heat dissipation design


Core Capabilities

1. Simulating Real-World Charging Scenarios

The load bank's ability to emulate various load conditions allows for comprehensive testing of EV charging stations. By adjusting the load in increments, it replicates the dynamic charging profiles encountered during actual EV charging sessions. This simulation aids in assessing the performance and reliability of charging equipment under different operational scenarios.

2. Ensuring Compliance with Industry Standards

Adherence to international standards is crucial for the safety and interoperability of EV charging infrastructure. The GROADA-AC220V-60KW-R Load Bank supports compliance with key standards such as:

  • IEC 61851: Electric vehicle conductive charging system

  • SAE J1772: Standard for electrical connectors for electric vehicles

  • UL 2231-1: Safety standard for protection against electric shock and ground faults in EV charging systems

These standards ensure that charging stations are safe, efficient, and compatible with a wide range of EV models.

3. Enhancing Safety and Reliability

The load bank's built-in protection mechanisms safeguard both the testing equipment and the charging station under test. Features like overload, over-temperature, and short-circuit protection prevent potential damage during testing, ensuring the longevity and reliability of both the load bank and the charging infrastructure.

4. Facilitating Research and Development

For manufacturers and developers, the load bank serves as an invaluable tool in the R&D phase. It allows for the evaluation of new charging technologies, the optimization of charging algorithms, and the identification of potential issues before deployment. This proactive approach accelerates innovation and enhances the quality of EV charging solutions.


Industry Implications

The integration of load banks like the GROADA-AC220V-60KW-R into the testing protocols of EV charging stations aligns with the industry's shift towards stringent safety and performance standards. Governments and regulatory bodies are increasingly mandating regular testing and certification of charging infrastructure to ensure public safety and grid stability. By adopting such testing solutions, stakeholders can demonstrate compliance, mitigate risks, and contribute to the development of a robust EV charging ecosystem.


Conclusion

The GROADA-AC220V-60KW-R Charging Pile Load Bank stands as a testament to the industry's commitment to quality, safety, and innovation in EV charging infrastructure. Its advanced features, coupled with adherence to international standards, make it an indispensable tool for manufacturers, developers, and operators aiming to deliver reliable and efficient EV charging solutions. By investing in such testing equipment, stakeholders not only ensure the optimal performance of their charging stations but also contribute to the broader goal of sustainable and safe electric mobility.