GROADA-DC1000V-200KW-R DC charging load bank
GROADA-DC1000V-200KW-R DC Charging Load_Shenzhen Guang Lu Da Electronics Co., Ltd. is a high-tech en...
| Rated power | 0-6KW | 0-30KW | 0-60KW | 0-100KW | 0-200KW | 0-400KW | 0-500KW | 0-1000KW |
| Size (width * depth * height mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Weight | 25KG | 80KG | 130KG | 180KG | 250KG | 550KG | 650KG | 1100KG |
| Input current | 0-30A | 0-45A | 0-90A | 0-150A | 0-300A | 0-600A | 0-750A | 0-1500A |
| Power | PF=1.0 | |||||||
| Overall accuracy | 3% (other accuracy requirements can be customized according to requirements) | |||||||
| Control mode | Local manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required) | |||||||
| Remote Interface | RS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements) | |||||||
| Protection function | Emergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume) | |||||||
| Display accuracy | 0.5 level (other explicit precision can be customized according to requirements | |||||||
| Display parameters | Voltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements) | |||||||
| Cold sure way | Forward and out | Side air inlet and upper air outlet (other air outlet methods can be customized according to requirements) | ||||||
| Protection level | IP20 (other protection level can be customized according to requirements) | |||||||
| Appearance color | RAL7035 (other colors can be customized according to requirements) | |||||||
| Working temperature | -10 ℃ ~ 55 ℃ | |||||||
| Relative humidity | ≤95%RH | |||||||
| Altitude | ≤ 2500 m | |||||||
As the global electric vehicle (EV) market accelerates, the demand for reliable and efficient EV charging infrastructure intensifies. Ensuring the performance and safety of charging stations is paramount. The GROADA DC750V-50KW-R Charging Pile Load Bank emerges as a pivotal solution, offering advanced testing capabilities to simulate real-world charging scenarios.
Voltage Range: Supports up to 750V DC, accommodating a diverse range of EV charging systems.
Power Capacity: Delivers a maximum load of 50kW, suitable for testing both low and high-power charging stations.
Load Type: Features a resistive load design, providing stable and accurate simulations of actual charging conditions.
Control Interface: Equipped with an intuitive touch screen interface, allowing for seamless operation and real-time monitoring.
Safety Features: Incorporates overcurrent, overvoltage, and thermal protection mechanisms to ensure the safety of both equipment and personnel.
The GROADA DC750V-50KW-R Load Bank serves multiple critical functions in the development and maintenance of EV charging stations:
Design Validation: Engineers utilize the load bank to simulate diverse EV charging profiles, ensuring that charging stations are designed to handle expected loads efficiently.
Performance Testing: Regular testing with the load bank verifies that charging stations maintain optimal performance under varying load conditions.
Compliance Assurance: Facilitates adherence to international standards such as IEC 61851 and national regulations, streamlining the certification process.
Diagnostic Tool: Serves as an essential tool for identifying and rectifying issues in charging equipment, thereby minimizing downtime and enhancing reliability.
Adhering to established standards is crucial for ensuring the safety and efficiency of EV charging stations:
IEC 61851: Specifies general requirements for EV charging systems, encompassing safety measures and communication protocols.
GB/T 20234.2: Chinese national standard outlining the technical requirements for AC/DC charging connectors and communication protocols.
UL 2202: Standard for the safety of EV charging equipment in the United States, focusing on electrical and mechanical safety aspects.
Utilizing the GROADA DC750V-50KW-R Load Bank ensures that testing procedures align with these standards, promoting the development of safe and reliable charging infrastructure.
The GROADA DC750V-50KW-R Charging Pile Load Bank is an indispensable tool for the EV charging industry. By providing accurate simulations of real-world charging scenarios, it enables manufacturers and operators to deliver high-quality, compliant, and safe charging solutions. Investing in such advanced testing equipment is essential for the sustainable growth of the EV industry and the transition towards a greener future.