GROADA-DC60V-270A-R Load Bank Factory
型号GROADA-DC48V-RGROADA-DC60V-RGROADA-DC110V-RGROADA-DC220V-RGROADA-DC500V-RGROADA-DC750V-RGROADA-DC1...
| Model | GROADA-DC48V-R | GROADA-DC60V-R | GROADA-DC110V-R | GROADA-DC220V-R | GROADA-DC500V-R | GROADA-DC750V-R | GROADA-DC1000V-R |
| Rated current | 0 ~ 5000A | ||||||
| Input voltage | 0~1500V | ||||||
| Minimum loading | 0.1A | ||||||
| Other minimum loading can be customized according to requirements | |||||||
| Overall accuracy | 3% (other accuracy requirements can be customized according to requirements) | ||||||
| Control mode | Local manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required) | ||||||
| Remote Interface | RS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements) | ||||||
| Protection function | Emergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume) | ||||||
| Working power supply | GROADA/AC380V | ||||||
| Display accuracy | 0.5 level (other explicit precision can be customized according to requirements) | ||||||
| Display parameters | Voltage, current, power, etc. | ||||||
| Cold sure way | Side air inlet and upper air outlet (other air outlet methods can be customized according to requirements) | ||||||
| Protection level | IP20 (other protection level can be customized according to requirements) | ||||||
| Appearance color | RAL7035 (other colors can be customized according to requirements) | ||||||
| Working temperature | -10 ℃ ~ 55 ℃ | ||||||
| Relative humidity | ≤95%RH | ||||||
| Altitude | ≤ 2500 m | ||||||
Engineered for Critical Power Testing, Validation & Maintenance
In modern energy, telecom, data center and industrial infrastructures, uninterrupted DC power is a backbone. The GROADA DC220V-50A-R load bank is tailor-designed to simulate real-world DC loads with precision, stability, and safety — helping you validate, stress-test, and maintain DC systems with confidence.
A load bank lets you apply a controlled electrical load onto a DC source (e.g. battery strings, power supplies, rectifiers) and dissipate that energy as heat, allowing you to measure voltage behavior, current draw, system resilience under load, and detect hidden faults in advance.
Unlike AC load banks, DC load banks are designed to mimic steady DC current draw, which is essential for battery discharge testing, maintenance of telecom DC systems, and commissioning of DC power modules.
In many mission-critical installations (data centers, telecom shelters, UPS systems), even small deviations under load can lead to system failure, downtime, or battery aging. Routine, repeatable load testing is one of the most important preventive maintenance tasks.
Below is a representative specification set for the GROADA DC220V-50A-R (you should confirm exact specs):
| Parameter | Value / Range | Importance / Comment |
|---|---|---|
| Rated Voltage | 220 V DC | Suitable for common telecom / battery bus voltages |
| Rated Current | 50 A | Provides up to 11 kW load capacity (220 V × 50 A) |
| Load Mode | Resistive / Constant-current | Supports stable current draw independent of minor voltage drift |
| Resolution & Steps | 0.1 A increments | Fine granularity for accurate tuning and partial loading |
| Control & Display | Digital interface, status LEDs, fault indicators | User-friendly monitoring and load control |
| Cooling / Heat Dissipation | Forced air cooling, thermal protection | Ensures safe operation and longevity under continuous load |
| Protection Features | Over-temperature, over-current, emergency stop, airflow fail | Ensures operator safety and protects both load bank and test object |
By implementing high-precision control and robust hardware, this unit ensures that your test environment is stable, repeatable, and reliable.
The GROADA DC220V-50A-R is a versatile tool for many DC power system applications:
Battery Capacity & Discharge Testing: Accurately deplete battery strings to target depths-of-discharge, verify battery health, capacity fade, and aging behavior.
Commissioning & Acceptance Tests: Validate new battery banks, DC distribution systems, and rectifier–inverter modules before putting them into service.
Maintenance & Preventive Diagnostics: Detect internal faults, weak cells, voltage drop under load, or irregular behavior before system failure in the field.
UPS / DC Power Supply Testing: Simulate real load situations on DC power supplies, converters, or DC bus setups for stress testing.
Telecom, Data Center Infrastructure, Industrial Power: Many critical installations use DC power rails (e.g. -48 V, 110 V, 220 V). The load bank provides critical validation under real-life conditions.
Renewables / Energy Storage Systems: In systems involving photovoltaic or battery storage generating DC, this unit helps validate performance, discharge response, and system stability.
To help your product stand out, the marketing copy should emphasize the following strengths (assuming your design supports them):
High Accuracy & Stability
Using precision resistive elements and microprocessor control, the load bank maintains stable current draw even as voltage drifts, minimizing test error and drift.
Fine Granularity & Step Control
With fine step resolution (e.g. 0.1 A), you can configure partial loading (e.g. 10%, 25%, 50% of rated) to simulate a variety of operational conditions.
Safety & Protection Built In
Integrated over-temperature, over-current, airflow failure cutoffs, and emergency-stop mechanisms protect both your device under test and operator safety.
Durability & Long-Term Reliability
Designed for continuous operation, heat management, and rugged environments. Use of quality components prolongs service life and reduces maintenance.
Ease of Use & Monitoring
Digital interface, clear indicators, real-time status display, and logging capabilities (if supported) reduce operator error and increase usability in field operations.
Scalable & Flexible Deployment
Though this is a 220 V / 50 A model, you can highlight modular or parallel-load capability, multi-voltage variants, or customization options — showing that you can support from small to large systems.
Local Support, Quality Assurance & Compliance
Emphasize that you provide technical support, warranty, certification (e.g. CE, ISO, safety compliance), and possibly reference case studies or field deployments to build authority and trust.
The global load bank market (AC + DC combined) was valued around USD 300 million in 2025 and forecasts anticipate growth to USD 387.15 million by 2032 at ~3.7% CAGR.
Some more aggressive estimates (focusing on DC / high-performance segments) foresee faster growth (e.g. CAGR ~6.2%) and markets reaching over USD 500 million by 2032.
The demand is fueled by expanding data centers, telecom infrastructure upgrades, renewable energy projects, and higher reliability expectations across industrial sectors.
By positioning your product in this growth trajectory and explicitly aligning with industry trends, you show that your offering is not a niche gadget but a strategic, future-oriented solution.