RCD Load Bank

GROADA-AC120V-5KW-RCD Load Bank Manufacturer

★★★★★
Main Products:
  • AC Load Bank : R / RL / RLC / RCD
  • DC Load Bank : DC5V - 2000V, 0A - 5000A


ModelAC220V-5KW-RCDAC220V-10KW-RCDAC220V-15KW-RCDAC220V-20KW-RCDAC380V-30KW-RCDAC380V-50KW-RCDAC380V-60KW-RCDAC380V-100KW-RCDAC380V-200KW-RCD
Rated powerR=5KWR=10KWR=15KWR=20KWR=30KWR=50KWR=60KWR=100KWR=200KW
RCD=5KVARCD=10KVARCD=15KVARCD=20KVARCD=30KVARCD=50KVARCD=60KVARCD=100KVARCD=200KVA
Input current0-22A0-45A0-45A0-90A0-45A0-300A0-450A0-600A0-750A
Size (width * depth * height mm)500*600*800500*600*1000500*600*1100500*750*1100600*850*1400600*850*1600600*850*1850700*1000*18001100*1400*1800
Weight50KG80KG100KG130KG200KG300KG350KG450KG550KG
Input voltageAC220/230VAC380/400V
Other input voltage can be customized according to requirements
Minimum loading100W100W100W100W100W1KW1KW1KW1KW
Other minimum loading power can be customized according to requirements
Overall accuracy3% (other accuracy requirements can be customized according to requirements)
power factorPF=0.6~1.0
peak coefficient2 to 3
Control modeLocal manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required)
Remote InterfaceRS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements)
Protection functionEmergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume)
Working power supplyAC220VAC220V/AC380V
Display accuracy0.5 level (other explicit precision can be customized according to requirements)
Display parametersVoltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements)
Cold sure waySide air inlet and upper air outlet (other air outlet methods can be customized according to requirements)
Protection levelIP20 (other protection level can be customized according to requirements)
Appearance colorRAL7035 (other colors can be customized according to requirements)
Working temperature-10 ℃ ~ 55 ℃
Relative humidity≤95%RH
Altitude≤ 2500 m



GROADA AC120V-5KW RCD Load Bank – Advanced Nonlinear Load Testing Solution


Overview

The GROADA AC120V-5KW RCD Load Bank is a high-precision testing device designed to simulate nonlinear electrical loads, offering reliable performance validation for power systems. Perfect for applications such as UPS systems, data centers, telecommunications networks, and industrial power setups, this load bank ensures power sources can handle complex reactive loads safely and efficiently.

By accurately mimicking real-world power demand conditions, it enables engineers to assess system stability, efficiency, and resilience before deployment.


Key Features

  • Rated Power: 5 kW

  • Voltage Compatibility: AC 120V

  • Load Type: Nonlinear RCD (Resistive-Capacitive-Dynamic)

  • Load Adjustment: Stepwise incremental load control for precise testing

  • Cooling System: High-efficiency forced-air cooling to maintain optimal operation

  • Control Interface: Intuitive manual control panel with optional remote operation

  • Safety Protections: Overload, over-temperature, and short-circuit safeguards

  • Compliance: Designed to meet international electrical testing standards


Industry Applications

Data Centers

Validate UPS and generator performance under dynamic and nonlinear load conditions to prevent downtime and maintain uninterrupted service.

Telecommunications

Ensure reliable power delivery for critical communication systems, supporting continuous network operation.

Renewable Energy Systems

Test inverters and energy storage devices under fluctuating load conditions, confirming operational stability.

Industrial & Manufacturing

Simulate heavy machinery and production equipment load profiles, verifying power supply adequacy and system resilience.


Market Insights

The global load bank market is growing rapidly, driven by the increasing complexity of power systems and the rising need for reliable energy infrastructure. Forecasts predict market expansion from USD 288 million in 2024 to over USD 387 million by 2032, emphasizing the importance of high-quality testing devices like the GROADA AC120V-5KW RCD Load Bank.

This growth underscores a broader industry trend: increasing demand for precision load testing equipment to optimize system performance, improve energy efficiency, and mitigate risk in critical infrastructure.


Why Choose GROADA AC120V-5KW RCD Load Bank?

  • High Accuracy: Simulates real-world nonlinear loads to provide precise performance data.

  • Versatile Application: Suitable for UPS, telecom, renewable energy, and industrial systems.

  • Reliability: Constructed with premium components for long-lasting operation.

  • Ease of Operation: Simple, safe controls with comprehensive protective mechanisms.


Conclusion

Investing in the GROADA AC120V-5KW RCD Load Bank ensures that your power systems are rigorously tested, resilient, and ready for complex operational scenarios. Its combination of precision, safety, and versatility makes it a critical tool for engineers and facility managers aiming to enhance power reliability and prevent costly downtime.

Our Product