GROADA-AC120V-5KW-RCD Load Bank Manufacturer
The GROADA AC120V-5KW RCD Load Bank is a high-precision testing device designed to simulate nonlinea...
| Model | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380V-30KW-RCD | AC380V-50KW-RCD | AC380V-60KW-RCD | AC380V-100KW-RCD | AC380V-200KW-RCD |
| Rated power | R=5KW | R=10KW | R=15KW | R=20KW | R=30KW | R=50KW | R=60KW | R=100KW | R=200KW |
| RCD=5KVA | RCD=10KVA | RCD=15KVA | RCD=20KVA | RCD=30KVA | RCD=50KVA | RCD=60KVA | RCD=100KVA | RCD=200KVA | |
| Input current | 0-22A | 0-45A | 0-45A | 0-90A | 0-45A | 0-300A | 0-450A | 0-600A | 0-750A |
| Size (width * depth * height mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Weight | 50KG | 80KG | 100KG | 130KG | 200KG | 300KG | 350KG | 450KG | 550KG |
| Input voltage | AC220/230V | AC380/400V | |||||||
| Other input voltage can be customized according to requirements | |||||||||
| Minimum loading | 100W | 100W | 100W | 100W | 100W | 1KW | 1KW | 1KW | 1KW |
| Other minimum loading power can be customized according to requirements | |||||||||
| Overall accuracy | 3% (other accuracy requirements can be customized according to requirements) | ||||||||
| power factor | PF=0.6~1.0 | ||||||||
| peak coefficient | 2 to 3 | ||||||||
| Control mode | Local manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required) | ||||||||
| Remote Interface | RS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements) | ||||||||
| Protection function | Emergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume) | ||||||||
| Working power supply | AC220V | AC220V/AC380V | |||||||
| Display accuracy | 0.5 level (other explicit precision can be customized according to requirements) | ||||||||
| Display parameters | Voltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements) | ||||||||
| Cold sure way | Side air inlet and upper air outlet (other air outlet methods can be customized according to requirements) | ||||||||
| Protection level | IP20 (other protection level can be customized according to requirements) | ||||||||
| Appearance color | RAL7035 (other colors can be customized according to requirements) | ||||||||
| Working temperature | -10 ℃ ~ 55 ℃ | ||||||||
| Relative humidity | ≤95%RH | ||||||||
| Altitude | ≤ 2500 m | ||||||||
The GROADA AC220V 1.2kW/10-Group RCD Load Bank is engineered to provide precise, reliable simulation of nonlinear electrical loads, ensuring power systems are thoroughly tested under real-world operating conditions. Nonlinear loads, common in modern electronics, servers, and industrial equipment, create complex current and voltage characteristics that can stress power supplies. This load bank is designed to replicate these conditions, giving engineers and facility managers a dependable tool for evaluating and validating power infrastructure performance.
Whether for data centers, uninterruptible power supplies (UPS), or inverter systems, this RCD load bank ensures operational stability, safety, and long-term equipment reliability.
The load bank consists of 10 independent 120W resistive units, allowing incremental load testing and easy scaling to match the system under evaluation.
Users can combine or isolate groups to simulate various load patterns, from light to full capacity.
Precisely control the power factor to mimic real-world nonlinear load scenarios.
Supports a broad range of testing conditions, ensuring comprehensive evaluation of power sources.
Built-in protections include overload, short circuit, and over-temperature safeguards.
Ensures safe operation during testing, protecting both the load bank and the connected equipment.
Equipped with a digital display providing real-time monitoring of voltage, current, and load conditions.
Intuitive interface allows quick setup, accurate measurement, and detailed data logging.
The GROADA RCD Load Bank is indispensable for testing and validating power systems in environments with complex load demands, including:
Data Centers: Accurately simulate server farms and networking equipment to ensure uninterrupted operation under nonlinear load conditions.
UPS Systems: Validate performance and efficiency, confirming backup power remains stable during varying load conditions.
Inverter Systems: Assess the capacity of inverters to handle dynamic and fluctuating loads without compromising output stability.
Industrial and Laboratory Environments: Ideal for R&D, preventive maintenance, and compliance testing of electrical systems.
| Parameter | Specification |
|---|---|
| Rated Voltage | AC 220V |
| Total Power Capacity | 1.2kW |
| Load Units | 10 independent 120W resistive modules |
| Protection Features | Overload, short circuit, over-temperature |
| Control Interface | Digital display with manual adjustment options |
| Power Factor | Adjustable to simulate various load scenarios |
The load bank market is experiencing significant growth, driven by the increasing complexity of electrical systems and demand for reliable power testing.
The global market is projected to expand from USD 288.17 million in 2024 to USD 387.15 million by 2032, with a CAGR of 3.70%.
North America remains a key region, with high adoption in data centers, telecommunication facilities, and industrial plants.
The rise of sensitive electronic equipment and stringent power reliability standards is pushing organizations to invest in precision load testing solutions.
Reliability: Designed for continuous operation under challenging conditions.
Precision: Accurately simulates nonlinear loads, ensuring valid and repeatable test results.
Safety: Advanced protection systems reduce risk to both operators and equipment.
Versatility: Suitable for diverse applications, from laboratory testing to industrial-scale operations.
The GROADA AC220V 1.2kW/10-Group RCD Load Bank is a comprehensive solution for modern power system testing, providing engineers with the confidence that their equipment can withstand complex load conditions, maintain stability, and operate safely.