GROADA-AC120V-5KW-RCD Load Bank Manufacturer
The GROADA AC120V-5KW RCD Load Bank is a high-precision testing device designed to simulate nonlinea...
| Model | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380V-30KW-RCD | AC380V-50KW-RCD | AC380V-60KW-RCD | AC380V-100KW-RCD | AC380V-200KW-RCD |
| Rated power | R=5KW | R=10KW | R=15KW | R=20KW | R=30KW | R=50KW | R=60KW | R=100KW | R=200KW |
| RCD=5KVA | RCD=10KVA | RCD=15KVA | RCD=20KVA | RCD=30KVA | RCD=50KVA | RCD=60KVA | RCD=100KVA | RCD=200KVA | |
| Input current | 0-22A | 0-45A | 0-45A | 0-90A | 0-45A | 0-300A | 0-450A | 0-600A | 0-750A |
| Size (width * depth * height mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Weight | 50KG | 80KG | 100KG | 130KG | 200KG | 300KG | 350KG | 450KG | 550KG |
| Input voltage | AC220/230V | AC380/400V | |||||||
| Other input voltage can be customized according to requirements | |||||||||
| Minimum loading | 100W | 100W | 100W | 100W | 100W | 1KW | 1KW | 1KW | 1KW |
| Other minimum loading power can be customized according to requirements | |||||||||
| Overall accuracy | 3% (other accuracy requirements can be customized according to requirements) | ||||||||
| power factor | PF=0.6~1.0 | ||||||||
| peak coefficient | 2 to 3 | ||||||||
| Control mode | Local manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required) | ||||||||
| Remote Interface | RS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements) | ||||||||
| Protection function | Emergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume) | ||||||||
| Working power supply | AC220V | AC220V/AC380V | |||||||
| Display accuracy | 0.5 level (other explicit precision can be customized according to requirements) | ||||||||
| Display parameters | Voltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements) | ||||||||
| Cold sure way | Side air inlet and upper air outlet (other air outlet methods can be customized according to requirements) | ||||||||
| Protection level | IP20 (other protection level can be customized according to requirements) | ||||||||
| Appearance color | RAL7035 (other colors can be customized according to requirements) | ||||||||
| Working temperature | -10 ℃ ~ 55 ℃ | ||||||||
| Relative humidity | ≤95%RH | ||||||||
| Altitude | ≤ 2500 m | ||||||||
The GROADA AC380V 30KW RCD Load Bank is a state-of-the-art solution for testing and validating modern power systems. Designed to replicate real-world electrical conditions, it provides precise simulation of non-linear loads, enabling engineers to assess the performance, efficiency, and reliability of generators, UPS systems, inverters, and other critical power equipment.
Whether for industrial operations, data centers, or renewable energy installations, this load bank ensures your systems are robust, resilient, and ready for any electrical scenario.
| Feature | Specification |
|---|---|
| Rated Power | 30 kW (Resistive) / 30 kVA (Capacitive) |
| Voltage | AC 380V, 3-phase |
| Frequency | 50/60 Hz |
| Power Factor Range | 0.6 – 1.0 (adjustable) |
| Maximum Current | Up to 576A (3-phase) |
| Load Type | Resistive-Capacitive (RCD) |
| Safety Protections | Overcurrent, overvoltage, overtemperature, emergency stop |
Key Insight: The combination of resistive and capacitive elements allows this load bank to generate non-linear load profiles that closely mimic modern electronic equipment behavior, ensuring realistic testing conditions.
Modern electrical systems often encounter non-linear loads due to electronic devices like computers, servers, and inverters. The RCD load bank replicates these conditions, allowing engineers to evaluate power system performance, including voltage stability, current harmonics, and thermal response under real operating scenarios.
The power factor adjustment range (0.6–1.0) ensures that your equipment can be tested under a variety of load conditions, from capacitive-heavy to predominantly resistive loads. This flexibility is critical for validating UPS, generator, and inverter performance under diverse operational scenarios.
With the ability to handle up to 576A in three-phase configurations, this load bank is suitable for medium to high-capacity power systems. It allows full-load testing without overloading the equipment under test, ensuring reliability and operational safety.
Safety is paramount in load testing. The GROADA RCD Load Bank is equipped with:
Overcurrent protection to prevent excessive load damage
Overvoltage protection to safeguard connected equipment
Overtemperature protection for internal heating control
Emergency stop for immediate shutdown during unexpected situations
The digital display provides continuous monitoring of:
Voltage and current
Real-time power consumption
Power factor and load distribution
This ensures precise, data-driven testing with minimal operator error.
The GROADA AC380V 30KW RCD Load Bank is ideal across multiple sectors:
Data Centers: Test UPS and backup generators under realistic, fluctuating load conditions.
Telecommunications: Validate the reliability of inverters and backup power for mission-critical networks.
Industrial Manufacturing: Confirm generator and electrical system resilience in factories and production facilities.
Renewable Energy: Evaluate inverters and hybrid energy systems in solar and wind installations to ensure optimal performance.
This load bank aligns with industry standards and best practices, including:
IEEE 1547 – Interconnection and performance of distributed energy resources
IEEE 112.3 – Generator testing methods
ISO 8528 – Reciprocating internal combustion engine-driven generating sets
Compliance guarantees trustworthy, repeatable testing results for both local and international projects.
Enhanced Testing Accuracy: Realistic simulation of non-linear loads ensures precise system evaluation.
Wide Application Range: Suitable for data centers, industrial sites, telecom networks, and renewable energy projects.
Long-Term Reliability: High-quality components for consistent performance over time.
Operator Safety: Built-in protections and emergency stop mechanisms safeguard users and equipment.
Investing in the GROADA AC380V 30KW RCD Load Bank means preparing your power systems for real-world demands, minimizing downtime, and optimizing operational efficiency.