RCD Load Bank

GROADA-AC380V-60KW-R/RCD Load Bank Supplier

★★★★★
Main Products:
  • AC Load Bank : R / RL / RLC / RCD
  • DC Load Bank : DC5V - 2000V, 0A - 5000A


ModelAC220V-5KW-RCDAC220V-10KW-RCDAC220V-15KW-RCDAC220V-20KW-RCDAC380V-30KW-RCDAC380V-50KW-RCDAC380V-60KW-RCDAC380V-100KW-RCDAC380V-200KW-RCD
Rated powerR=5KWR=10KWR=15KWR=20KWR=30KWR=50KWR=60KWR=100KWR=200KW
RCD=5KVARCD=10KVARCD=15KVARCD=20KVARCD=30KVARCD=50KVARCD=60KVARCD=100KVARCD=200KVA
Input current0-22A0-45A0-45A0-90A0-45A0-300A0-450A0-600A0-750A
Size (width * depth * height mm)500*600*800500*600*1000500*600*1100500*750*1100600*850*1400600*850*1600600*850*1850700*1000*18001100*1400*1800
Weight50KG80KG100KG130KG200KG300KG350KG450KG550KG
Input voltageAC220/230VAC380/400V
Other input voltage can be customized according to requirements
Minimum loading100W100W100W100W100W1KW1KW1KW1KW
Other minimum loading power can be customized according to requirements
Overall accuracy3% (other accuracy requirements can be customized according to requirements)
power factorPF=0.6~1.0
peak coefficient2 to 3
Control modeLocal manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required)
Remote InterfaceRS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements)
Protection functionEmergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume)
Working power supplyAC220VAC220V/AC380V
Display accuracy0.5 level (other explicit precision can be customized according to requirements)
Display parametersVoltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements)
Cold sure waySide air inlet and upper air outlet (other air outlet methods can be customized according to requirements)
Protection levelIP20 (other protection level can be customized according to requirements)
Appearance colorRAL7035 (other colors can be customized according to requirements)
Working temperature-10 ℃ ~ 55 ℃
Relative humidity≤95%RH
Altitude≤ 2500 m



GROADA AC380V 60KW R/RCD Load Bank – Advanced Power Testing Solution

Overview

The GROADA AC380V 60KW R/RCD Load Bank is a professional-grade power testing device engineered for reliable and accurate evaluation of electrical power systems. Combining resistive, reactive, and capacitive loads (R/RCD) in a single unit, this load bank allows engineers and technicians to simulate real-world operational conditions. It is ideal for generators, UPS systems, and industrial power infrastructure, ensuring optimal performance and safety under various load scenarios.

Designed for precision and durability, this load bank meets rigorous industrial standards and provides a robust solution for testing, maintenance, and system verification.


Key Features

1. Comprehensive Load Simulation

  • Combines resistive, reactive, and capacitive loads to replicate the performance of modern electronic equipment and complex power systems.

  • Supports real-world testing for generators, UPS, and critical power systems, ensuring reliability under dynamic load conditions.

2. High Power Capacity

  • Delivers 60KW of total load capacity, suitable for medium to large-scale industrial applications.

  • Can handle a variety of load configurations, providing flexibility for diverse testing requirements.

3. Precision Voltage Compatibility

  • Optimized for AC380V systems, with customizable voltage options for international applications.

  • Ensures accurate simulation for different electrical standards, enhancing testing efficiency.

4. Advanced Control and Monitoring

  • Equipped with a digital control panel for real-time monitoring of voltage, current, power, and load distribution.

  • Allows precise adjustment of load levels, supporting step-load testing, ramp testing, and continuous load testing.

5. Safety-First Design

  • Features overcurrent, overvoltage, and thermal protection mechanisms, safeguarding both the device and the system under test.

  • Incorporates emergency shutdown and fault detection to minimize operational risk.


Applications

The GROADA AC380V 60KW R/RCD Load Bank is designed for a wide array of critical applications:

  • Generator Testing: Validate generator capacity and performance under controlled resistive, reactive, and capacitive loads.

  • UPS System Verification: Evaluate the reliability and efficiency of uninterruptible power supplies in real-world scenarios.

  • Data Center Maintenance: Ensure uninterrupted operation of critical IT infrastructure by simulating peak and variable loads.

  • Industrial and Commercial Power Systems: Test power grids, substations, and industrial machinery for stability and efficiency.


Industry Insights

The global load bank market is growing steadily due to the increasing demand for reliable and uninterrupted power solutions. According to market research, the sector is expected to expand from $300 million in 2025 to over $387 million by 2032, driven by the proliferation of data centers, renewable energy integration, and industrial automation.

Modern load banks are evolving with trends such as:

  • Modular designs for scalable testing solutions.

  • Digital monitoring for precise and automated load management.

  • Networked load banks for synchronized testing across multiple units.

  • Energy-efficient components reducing operational costs and environmental impact.

The GROADA R/RCD Load Bank incorporates these trends, delivering a cutting-edge testing tool that is both versatile and future-proof.


Why Choose GROADA Load Banks?

  1. Proven Expertise: Decades of experience in manufacturing industrial-grade load banks.

  2. Customization: Tailored solutions to meet specific load testing requirements.

  3. Reliability: Built for long-term durability and consistent performance in demanding environments.

  4. Comprehensive Support: End-to-end guidance, including installation, calibration, and technical troubleshooting.


Conclusion

For engineers and facility managers seeking a high-precision, reliable, and versatile load testing solution, the GROADA AC380V 60KW R/RCD Load Bank delivers unmatched performance. By simulating real-world load conditions, it ensures that generators, UPS systems, and industrial power networks operate safely and efficiently, reducing downtime and safeguarding critical infrastructure.