RCD Load Bank

GROADA-AC220V-15KW-RCD Load Bank Manufacturers

★★★★★
Main Products:
  • AC Load Bank : R / RL / RLC / RCD
  • DC Load Bank : DC5V - 2000V, 0A - 5000A


ModelAC220V-5KW-RCDAC220V-10KW-RCDAC220V-15KW-RCDAC220V-20KW-RCDAC380V-30KW-RCDAC380V-50KW-RCDAC380V-60KW-RCDAC380V-100KW-RCDAC380V-200KW-RCD
Rated powerR=5KWR=10KWR=15KWR=20KWR=30KWR=50KWR=60KWR=100KWR=200KW
RCD=5KVARCD=10KVARCD=15KVARCD=20KVARCD=30KVARCD=50KVARCD=60KVARCD=100KVARCD=200KVA
Input current0-22A0-45A0-45A0-90A0-45A0-300A0-450A0-600A0-750A
Size (width * depth * height mm)500*600*800500*600*1000500*600*1100500*750*1100600*850*1400600*850*1600600*850*1850700*1000*18001100*1400*1800
Weight50KG80KG100KG130KG200KG300KG350KG450KG550KG
Input voltageAC220/230VAC380/400V
Other input voltage can be customized according to requirements
Minimum loading100W100W100W100W100W1KW1KW1KW1KW
Other minimum loading power can be customized according to requirements
Overall accuracy3% (other accuracy requirements can be customized according to requirements)
power factorPF=0.6~1.0
peak coefficient2 to 3
Control modeLocal manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required)
Remote InterfaceRS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements)
Protection functionEmergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume)
Working power supplyAC220VAC220V/AC380V
Display accuracy0.5 level (other explicit precision can be customized according to requirements)
Display parametersVoltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements)
Cold sure waySide air inlet and upper air outlet (other air outlet methods can be customized according to requirements)
Protection levelIP20 (other protection level can be customized according to requirements)
Appearance colorRAL7035 (other colors can be customized according to requirements)
Working temperature-10 ℃ ~ 55 ℃
Relative humidity≤95%RH
Altitude≤ 2500 m



GROADA AC220V 15kW RCD Load Bank – Precision Testing for Non-Linear Loads

Overview

The GROADA AC220V 15kW RCD Load Bank is designed for accurate simulation and testing of non-linear electrical loads. It combines resistive and capacitive elements to closely replicate real-world load conditions, making it an essential tool for engineers, data centers, and power system professionals. Its high precision, robust safety features, and adherence to international standards ensure reliable performance for all testing scenarios.


Key Features

  • Dual Load Types: Integrates resistive and capacitive loads to emulate non-linear electrical behavior.

  • Adjustable Power Factor: Allows settings from 0.6 to 1.0 for flexible testing applications.

  • High Current Capacity: Supports up to 96A, suitable for rigorous operational tests.

  • Universal Voltage Compatibility: Optimized for 220V AC systems, with customizable options for different voltages.

  • Advanced Safety Protections: Includes overload, over-temperature, and short-circuit safeguards to ensure operational safety.


Applications

  • Generator Testing: Evaluates generator performance under complex, non-linear loads to guarantee operational stability.

  • UPS Systems Assessment: Simulates real-world load conditions to identify potential UPS performance issues.

  • Inverter and PV System Testing: Validates inverter and photovoltaic equipment efficiency and reliability.

  • Data Centers & Critical Infrastructure: Ensures uninterrupted and safe operation of mission-critical power systems.


Compliance & Standards

The AC220V 15kW RCD Load Bank adheres to global standards, ensuring credibility and safety:

  • IEEE 1547 – Distributed energy resources testing.

  • ISO 8528-10 – Generator load acceptance tests.

  • IEC 62040 – Performance requirements for UPS systems.

This compliance demonstrates reliability and builds trust with engineers and technical decision-makers.


Why Choose GROADA RCD Load Bank?

  • High Precision Testing: Simulates non-linear loads for realistic system evaluations.

  • Versatile & Adaptable: Compatible with a wide range of AC power systems.

  • Robust Safety Features: Protects both operators and equipment.

  • Durable Construction: Engineered for intensive testing environments.

  • User-Friendly Operation: Simplified interface for easy monitoring and control.


Technical Specifications

SpecificationDetails
Rated Capacity15kW Resistive / 15kVAR Capacitive
VoltageAC 220V Single Phase
Maximum Current96A
Frequency50/60 Hz
Power Factor0.6 – 1.0
Protection FeaturesOverload, Over-temperature, Short-circuit
Compliance StandardsIEEE 1547, ISO 8528-10, IEC 62040

Conclusion

The GROADA AC220V 15kW RCD Load Bank delivers unmatched precision and safety for non-linear load testing. Trusted by professionals worldwide, it ensures accurate system evaluations, enhances equipment reliability, and supports safe operation of critical power systems.


Contact Information

  • Email: groada@163.com

  • Phone: +86 755 2333 9096

  • Location: Shenzhen, Guangdong, China

GROADA is committed to advancing testing solutions that meet evolving industry standards and operational demands.