RLC Load Bank

GROADA-AC220V-20KW-RLC Load Bank Supplier

★★★★★
Main Products:
  • AC Load Bank : R / RL / RLC / RCD
  • DC Load Bank : DC5V - 2000V, 0A - 5000A


ModelAC220V-10KVA-RLCAC380V-30KVA-RLCAC380V-60KVA-RLCAC380V-100KVA-RLCAC380V-200KVA-RLCAC380V-300KVA-RLC
Rated powerRLC=10KVARLC=30KVARLC=60KVARLC=100KVARLC=200KVARLC=300KVA
R=10KW;L=10KVA
C=10KVA
R=30KW;L=30KVA;
C=30KVA
R=60KW;L=60KVA;
C=60KVA
R=100KW;L=100KVA;
C=100KVA
R=200KW;L=200KVA;
C=200KVA
R=300KW;L=300KVA;
C=300KVA
Other power can be customized according to requirements
Size (width * depth * height mm)500*750*1400600*850*15001000*1100*15001100*1600*15001500*1800*18002000*2000*2000
Weight120KG380KG580KG880KG1500KG2500KG
Input voltageAC220/230VAC380/400V
Other input voltage can be customized according to requirements
Input current0-45A0-45A0-90A0-150A0-300A0-450A
Minimum loadingR=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=1KW;L=1KVA;
C=1KVA
R=1KW;L=1KVA;
C=1KVA
Other minimum loading power can be customized according to requirements
power factorPF = 0.1~1.0 (other power factor can be customized according to requirements)
Overall accuracy3% (other accuracy requirements can be customized according to requirements)
Control modeLocal manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required)
Remote InterfaceRS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements)
Protection functionEmergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume)
Working power supplyAC220VAC220V/380VAC380V
Display accuracy0.5 level (other explicit precision can be customized according to requirements)
Display parametersVoltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements)
Cold sure waySide air inlet and upper air outlet (other air outlet methods can be customized according to requirements)
Protection levelIP20 (other protection level can be customized according to requirements)
Appearance colorRAL7035 (other colors can be customized according to requirements)
Working temperature-10 ℃ ~ 55 ℃
Relative humidity≤95%RH
Altitude≤ 2500 m



GROADA AC220V 20KW RLC Load Bank – Precision Power Testing for Modern Electrical Systems

The GROADA AC220V 20KW RLC Load Bank is a state-of-the-art testing solution designed to simulate real-world electrical loads across resistive (R), inductive (L), and capacitive (C) components. Engineered for versatility, accuracy, and safety, this load bank is ideal for power generators, UPS systems, turbines, battery systems, renewable energy installations, and electric vehicle charging stations. It enables engineers and technicians to validate and optimize electrical systems under controlled, yet realistic conditions.


🔹 Key Specifications

FeatureSpecification
ModelGROADA AC220V 20KW RLC
Rated Power20 kW
VoltageAC 220V
Frequency50/60 Hz
Power FactorAdjustable 0.1–1.0
Load Regulation±1% accuracy for resistance and reactance
Control ModesManual, Automatic, DSP Panel, Wireless Remote
Protection FeaturesOverload, Short Circuit, Overtemperature, Fan Stop, Fire Alarm
MeasurementBuilt-in power analyzer; remote monitoring supported

⚙️ Advanced Features and Advantages

1. Comprehensive Load Simulation

The RLC configuration accurately replicates real-world electrical conditions, including resistive, inductive, and capacitive loads. This ensures that equipment can be tested under varied operating conditions, including harmonic distortion, phase shifts, and power factor changes. Such testing is critical for generators, UPS systems, and other mission-critical equipment.

2. Precision Control

With advanced digital controls and DSP monitoring, the load bank allows fine-tuning of resistance and reactance. Operators can simulate precise load profiles, providing accurate, repeatable, and reliable testing results. Remote monitoring ensures safety and convenience during testing.

3. Modular and Scalable Design

The GROADA AC220V 20KW RLC Load Bank features a modular design, allowing multiple units to be networked together. This enables scalable testing for both small and large installations without increasing footprint or operational complexity.

4. Robust Protection and Safety

Multiple integrated safety features—such as overload protection, short circuit prevention, overtemperature detection, fan protection, and fire alarms—guarantee safe operation for both the load bank and the equipment under test. These protections reduce downtime and prevent costly damage.

5. Wide Industry Applications

The load bank supports diverse applications, from industrial generator testing to modern renewable energy systems. It is suitable for:

  • Generators: Validates performance and efficiency under variable loads.

  • UPS Systems: Ensures uninterrupted power supply reliability.

  • Turbines & Battery Systems: Tests energy storage and response under dynamic conditions.

  • Renewable Energy Installations: Simulates grid integration challenges.

  • EV Charging Infrastructure: Verifies load handling for charging stations.


📈 Industry Insights

The global load bank market is projected to grow from $303.2 million in 2025 to $412.9 million by 2032, reflecting the growing need for reliable testing solutions in industrial, commercial, and renewable energy sectors. Increased adoption of electric vehicles is expected to add up to 185 TWh to electricity demand by 2030, highlighting the critical importance of robust power testing and validation systems. Reliable load testing ensures optimal equipment performance, grid stability, and compliance with industry standards.


✅ Why Choose GROADA AC220V 20KW RLC Load Bank?

  • High Accuracy: ±1% load regulation ensures precise testing outcomes.

  • Versatility: Supports resistive, inductive, and capacitive load simulations.

  • Safety First: Comprehensive protection features safeguard both users and equipment.

  • Scalable Testing: Modular design allows for expansion to meet growing operational needs.

  • Compliance & Reliability: Meets international standards and industry regulations for high-performance testing equipment.

Investing in the GROADA AC220V 20KW RLC Load Bank ensures that your power systems are accurately tested, validated, and optimized for performance, minimizing operational risks and maximizing reliability.

Our Product