GROADA-AC220V-15KW-RLC Load Bank Manufacturer
The GROADA AC220V 15KW RLC Load Bank is engineered to provide comprehensive simulation of real-world...
| Model | AC220V-10KVA-RLC | AC380V-30KVA-RLC | AC380V-60KVA-RLC | AC380V-100KVA-RLC | AC380V-200KVA-RLC | AC380V-300KVA-RLC |
| Rated power | RLC=10KVA | RLC=30KVA | RLC=60KVA | RLC=100KVA | RLC=200KVA | RLC=300KVA |
| R=10KW;L=10KVA C=10KVA | R=30KW;L=30KVA; C=30KVA | R=60KW;L=60KVA; C=60KVA | R=100KW;L=100KVA; C=100KVA | R=200KW;L=200KVA; C=200KVA | R=300KW;L=300KVA; C=300KVA | |
| Other power can be customized according to requirements | ||||||
| Size (width * depth * height mm) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| Weight | 120KG | 380KG | 580KG | 880KG | 1500KG | 2500KG |
| Input voltage | AC220/230V | AC380/400V | ||||
| Other input voltage can be customized according to requirements | ||||||
| Input current | 0-45A | 0-45A | 0-90A | 0-150A | 0-300A | 0-450A |
| Minimum loading | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=1KW;L=1KVA; C=1KVA | R=1KW;L=1KVA; C=1KVA |
| Other minimum loading power can be customized according to requirements | ||||||
| power factor | PF = 0.1~1.0 (other power factor can be customized according to requirements) | |||||
| Overall accuracy | 3% (other accuracy requirements can be customized according to requirements) | |||||
| Control mode | Local manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required) | |||||
| Remote Interface | RS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements) | |||||
| Protection function | Emergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume) | |||||
| Working power supply | AC220V | AC220V/380V | AC380V | |||
| Display accuracy | 0.5 level (other explicit precision can be customized according to requirements) | |||||
| Display parameters | Voltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements) | |||||
| Cold sure way | Side air inlet and upper air outlet (other air outlet methods can be customized according to requirements) | |||||
| Protection level | IP20 (other protection level can be customized according to requirements) | |||||
| Appearance color | RAL7035 (other colors can be customized according to requirements) | |||||
| Working temperature | -10 ℃ ~ 55 ℃ | |||||
| Relative humidity | ≤95%RH | |||||
| Altitude | ≤ 2500 m | |||||
The GROADA AC415V-36KW RLC Load Bank is a cutting-edge, three-phase load testing solution engineered for the most demanding applications in power generation, industrial automation, renewable energy, and critical infrastructure systems. Combining resistive (R), inductive (L), and capacitive (C) loads in a single, high-performance unit, it provides comprehensive and precise simulation of real-world electrical conditions.
Tri-Load Capability: Simulates resistive, inductive, and capacitive loads to replicate diverse operating scenarios.
High Precision: Fine-tuned load regulation ensures outputs closely mirror real power consumption and reactive characteristics.
Safe and Reliable: Integrated protection against overcurrent, short circuit, overheating, and fan failures.
Robust Construction: Air-cooled design ensures efficient heat dissipation, even during prolonged operation.
Flexible Control: Local control panel with optional remote operation allows for versatile testing environments.
| Specification | Details |
|---|---|
| Rated Power | 36 kW |
| Rated Voltage | AC 415V, 3-phase, 4-wire |
| Control Mode | Local panel control with optional remote control |
| Load Regulation | Fine adjustment for precise load application |
| Protection Features | Overcurrent, overload, over-temperature, fan failure alarms |
| Cooling | Air-cooled for high-efficiency heat dissipation |
Resistive Load (R): Ideal for evaluating generators, UPS systems, and other power sources under real energy consumption.
Inductive Load (L): Accurately simulates motors, transformers, and reactive loads for power factor and stability testing.
Capacitive Load (C): Supports leading power factor conditions to test systems with power factor correction and energy storage integration.
The load bank offers precise step adjustments, ensuring each testing scenario closely matches actual operational conditions. This accuracy is critical for predictive maintenance, system validation, and compliance testing.
Engineered for industrial environments, the GROADA AC415V-36KW RLC Load Bank includes multiple layers of protection. Its rugged chassis, reliable cooling, and fail-safe design reduce downtime and safeguard both equipment and operators.
Data Centers: Test backup generators and UPS systems under real-world loads.
Telecommunications: Ensure uninterrupted power and stability for mission-critical networks.
Renewable Energy Integration: Validate solar, wind, and hybrid systems with reactive load testing.
Industrial Power Systems: Confirm generator performance, load distribution, and electrical system stability.
Electric Vehicle Infrastructure: Simulate complex load profiles for EV chargers and energy storage systems.
The global RLC load bank market is expanding rapidly due to the increasing need for reliable, high-performance power systems. Industries including data centers, renewable energy, industrial automation, and EV infrastructure are driving demand. As organizations prioritize energy efficiency, safety, and compliance with power standards, high-precision load banks like the GROADA AC415V-36KW become essential tools.
Three-phase systems dominate the market, with growing adoption in industrial and commercial facilities worldwide. By choosing GROADA, customers gain access to a solution that meets rigorous industry standards and ensures long-term operational reliability.
Versatile Testing: Supports resistive, inductive, and capacitive load testing in one unit.
Precision Control: Fine adjustments for accurate load simulation.
Robust Safety: Protects both the operator and connected systems.
Energy Efficient: Air-cooled design for prolonged and safe operation.
Industry Compliant: Meets global standards for load testing in critical applications.
For inquiries or a personalized consultation:
Email: groada@163.com
Phone: +86-755-23339096
Location: Shenzhen, Guangdong, China
Experience the reliability, precision, and versatility of the GROADA AC415V-36KW RLC Load Bank, designed to meet the most demanding testing requirements in modern power systems.