GROADA-AC220V-15KW-RLC Load Bank Manufacturer
The GROADA AC220V 15KW RLC Load Bank is engineered to provide comprehensive simulation of real-world...
| Model | AC220V-10KVA-RLC | AC380V-30KVA-RLC | AC380V-60KVA-RLC | AC380V-100KVA-RLC | AC380V-200KVA-RLC | AC380V-300KVA-RLC |
| Rated power | RLC=10KVA | RLC=30KVA | RLC=60KVA | RLC=100KVA | RLC=200KVA | RLC=300KVA |
| R=10KW;L=10KVA C=10KVA | R=30KW;L=30KVA; C=30KVA | R=60KW;L=60KVA; C=60KVA | R=100KW;L=100KVA; C=100KVA | R=200KW;L=200KVA; C=200KVA | R=300KW;L=300KVA; C=300KVA | |
| Other power can be customized according to requirements | ||||||
| Size (width * depth * height mm) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| Weight | 120KG | 380KG | 580KG | 880KG | 1500KG | 2500KG |
| Input voltage | AC220/230V | AC380/400V | ||||
| Other input voltage can be customized according to requirements | ||||||
| Input current | 0-45A | 0-45A | 0-90A | 0-150A | 0-300A | 0-450A |
| Minimum loading | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=1KW;L=1KVA; C=1KVA | R=1KW;L=1KVA; C=1KVA |
| Other minimum loading power can be customized according to requirements | ||||||
| power factor | PF = 0.1~1.0 (other power factor can be customized according to requirements) | |||||
| Overall accuracy | 3% (other accuracy requirements can be customized according to requirements) | |||||
| Control mode | Local manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required) | |||||
| Remote Interface | RS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements) | |||||
| Protection function | Emergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume) | |||||
| Working power supply | AC220V | AC220V/380V | AC380V | |||
| Display accuracy | 0.5 level (other explicit precision can be customized according to requirements) | |||||
| Display parameters | Voltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements) | |||||
| Cold sure way | Side air inlet and upper air outlet (other air outlet methods can be customized according to requirements) | |||||
| Protection level | IP20 (other protection level can be customized according to requirements) | |||||
| Appearance color | RAL7035 (other colors can be customized according to requirements) | |||||
| Working temperature | -10 ℃ ~ 55 ℃ | |||||
| Relative humidity | ≤95%RH | |||||
| Altitude | ≤ 2500 m | |||||
The GROADA AC800V 851kW RLC Three-Phase Load Bank is a high-performance testing instrument designed for large-scale electrical power systems. Integrating resistive (R), inductive (L), and capacitive (C) loads, it accurately simulates real-world operating conditions, enabling engineers and technicians to evaluate the performance, stability, and reliability of generators, UPS systems, switchgear, and other critical power infrastructure.
By providing precise, configurable loads, this RLC load bank ensures that power systems meet performance specifications, optimize efficiency, and maintain operational safety under varying load conditions. It is an essential tool for industries where uninterrupted, high-quality power is critical.
Rated at 851kW, the load bank is capable of testing large generators, industrial systems, and mission-critical infrastructure.
Supports full-load operation to validate maximum system performance without the risk of damage.
Designed for 800V AC three-phase systems, ensuring flexibility across multiple industrial and utility applications.
Compatible with various network configurations, supporting both balanced and unbalanced load testing.
Resistive loads (R) simulate active power consumption, critical for validating heating elements, motors, and resistive circuits.
Inductive loads (L) replicate reactive power demands, testing transformers, motors, and inductive components.
Capacitive loads (C) replicate reactive power compensation and power factor correction scenarios.
Allows for combined RLC load testing to simulate complex real-world power conditions.
Equipped with digital controllers and real-time monitoring systems, enabling fine-tuned load adjustments.
Provides accurate measurement of voltage, current, power factor, and frequency for detailed performance analysis.
Supports automated testing sequences to minimize human error and improve testing efficiency.
Engineered with durable materials and protective enclosures to withstand harsh industrial environments.
Features overload, over-temperature, and short-circuit protection, ensuring safe operation.
Designed for long-term use with minimal maintenance.
The GROADA AC800V RLC Load Bank is ideal for industries and scenarios requiring rigorous power testing:
Power Generation Plants: Commission and maintain generators to ensure compliance with operational and regulatory standards.
Data Centers: Test backup generators and UPS systems, ensuring reliable power supply during outages.
Industrial Manufacturing: Validate heavy machinery, motor drives, and production equipment under full-load conditions.
Military & Aerospace: Ensure operational readiness of critical power systems for mission-critical deployments.
Research & Testing Labs: Facilitate advanced testing, development, and certification of electrical equipment.
Enhanced Reliability: Identify potential issues before they lead to failures, minimizing downtime.
Improved Efficiency: Optimize generator and system performance by simulating real operational conditions.
Extended Equipment Life: Regular load testing reduces stress and wear on electrical systems, extending lifespan.
Regulatory Compliance: Supports adherence to industry standards, such as IEC and IEEE guidelines, ensuring quality and safety.
Data-Driven Insights: Detailed monitoring provides actionable data for performance optimization and predictive maintenance.
| Specification | Details |
|---|---|
| Rated Power | 851kW |
| Voltage | 800V AC, Three-Phase |
| Load Types | Resistive (R), Inductive (L), Capacitive (C) |
| Control | Advanced digital control with real-time monitoring |
| Protection | Overload, over-temperature, short-circuit, fan failure |
| Construction | Robust industrial-grade enclosure for harsh environments |
| Compliance | International load bank testing standards |
GROADA has over a decade of experience designing and manufacturing high-precision load banks for global clients. Our RLC load banks combine advanced engineering, user-friendly control interfaces, and industrial-grade durability, providing a reliable solution for power testing across diverse sectors.
Whether you are commissioning a new generator, validating industrial systems, or performing routine maintenance, the GROADA AC800V 851kW RLC Load Bank delivers accuracy, reliability, and peace of mind.
For inquiries, technical support, or a personalized quote, contact GROADA:
Email: groada@163.com
Phone: +86-755-23339096