RLC Load Bank

GROADA-AC480V-86KW-RLC Three Phase Load Bank

★★★★★
Main Products:
  • AC Load Bank : R / RL / RLC / RCD
  • DC Load Bank : DC5V - 2000V, 0A - 5000A


ModelAC220V-10KVA-RLCAC380V-30KVA-RLCAC380V-60KVA-RLCAC380V-100KVA-RLCAC380V-200KVA-RLCAC380V-300KVA-RLC
Rated powerRLC=10KVARLC=30KVARLC=60KVARLC=100KVARLC=200KVARLC=300KVA
R=10KW;L=10KVA
C=10KVA
R=30KW;L=30KVA;
C=30KVA
R=60KW;L=60KVA;
C=60KVA
R=100KW;L=100KVA;
C=100KVA
R=200KW;L=200KVA;
C=200KVA
R=300KW;L=300KVA;
C=300KVA
Other power can be customized according to requirements
Size (width * depth * height mm)500*750*1400600*850*15001000*1100*15001100*1600*15001500*1800*18002000*2000*2000
Weight120KG380KG580KG880KG1500KG2500KG
Input voltageAC220/230VAC380/400V
Other input voltage can be customized according to requirements
Input current0-45A0-45A0-90A0-150A0-300A0-450A
Minimum loadingR=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=1KW;L=1KVA;
C=1KVA
R=1KW;L=1KVA;
C=1KVA
Other minimum loading power can be customized according to requirements
power factorPF = 0.1~1.0 (other power factor can be customized according to requirements)
Overall accuracy3% (other accuracy requirements can be customized according to requirements)
Control modeLocal manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required)
Remote InterfaceRS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements)
Protection functionEmergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume)
Working power supplyAC220VAC220V/380VAC380V
Display accuracy0.5 level (other explicit precision can be customized according to requirements)
Display parametersVoltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements)
Cold sure waySide air inlet and upper air outlet (other air outlet methods can be customized according to requirements)
Protection levelIP20 (other protection level can be customized according to requirements)
Appearance colorRAL7035 (other colors can be customized according to requirements)
Working temperature-10 ℃ ~ 55 ℃
Relative humidity≤95%RH
Altitude≤ 2500 m


GROADA-AC480V-86KW-RLC Three-Phase Load Bank

High-Precision Load Testing for Industrial and Commercial Power Systems

In today’s rapidly evolving energy landscape, ensuring the reliability, efficiency, and safety of power systems is more critical than ever. The GROADA-AC480V-86KW-RLC Three-Phase Load Bank is a cutting-edge testing instrument designed to provide accurate simulation of complex electrical loads, helping engineers and technicians validate and optimize their power equipment with confidence.


Key Features and Capabilities

1. Comprehensive RLC Load Simulation

Unlike traditional resistive load banks, the GROADA RLC model integrates resistive (R), inductive (L), and capacitive (C) elements, allowing for realistic testing that mirrors actual operating conditions. This enables:

  • Accurate simulation of motor starting currents

  • Validation of reactive power compensation

  • Testing of power factor correction equipment

2. High-Power Capacity

Rated at 86 kW, this load bank is capable of handling substantial electrical loads, making it ideal for:

  • Large-scale generators

  • Industrial transformers

  • Data center UPS systems

3. Three-Phase AC Operation

Designed for 480V AC, 50/60 Hz three-phase systems, the unit is compatible with most industrial and commercial installations worldwide. It provides stable and reliable operation even under full-load conditions.

4. Advanced Monitoring and Control

Equipped with digital meters and monitoring interfaces, the load bank provides real-time insights into:

  • Voltage and current

  • Active, reactive, and apparent power

  • Power factor

  • Energy consumption and frequency

This ensures precise load management, reduces testing errors, and enhances overall operational safety.

5. Durable Industrial Design

Housed in a robust, ventilated enclosure, the GROADA load bank is built for long-term industrial use. It withstands harsh environmental conditions while ensuring safety for operators.


Applications

The GROADA-AC480V-86KW-RLC Three-Phase Load Bank serves a broad spectrum of industries:

  • Generator Testing: Validates performance and ensures generators can handle full-load conditions safely.

  • Transformer Load Testing: Assesses operational efficiency and thermal stability.

  • UPS Systems Verification: Simulates real-world loads to ensure uninterrupted power supply in critical applications.

  • Renewable Energy Integration: Tests the performance and stability of solar, wind, and hybrid systems under various load conditions.

  • Power Grid Maintenance: Provides controlled load testing for preventive maintenance and system diagnostics.


Industry Insights

The global load bank market is expanding rapidly, driven by the rise of industrial automation, renewable energy deployment, and the growing need for reliable power infrastructure. Key trends include:

  • Increased demand for high-capacity and versatile load testing solutions.

  • Greater adoption of RLC load banks for realistic simulation of inductive and capacitive loads.

  • Growth in sectors such as data centers, electric vehicle charging infrastructure, and renewable energy farms, which require rigorous load testing for operational reliability.

Analysts forecast the global load bank market to reach USD 445 million by 2034, growing at a CAGR of 4.8%, highlighting the increasing importance of advanced testing solutions.


Why Choose GROADA

  1. Precision and Reliability: Achieve up to ±0.5% accuracy for critical testing applications.

  2. Versatility: Simulate complex electrical loads across multiple industries.

  3. Durable Construction: Long-lasting performance in demanding environments.

  4. Advanced Monitoring: Real-time data ensures safety and operational insights.

  5. Global Compatibility: Designed for international three-phase systems.


Conclusion

The GROADA-AC480V-86KW-RLC Three-Phase Load Bank is more than a testing tool—it is a strategic investment in the reliability, efficiency, and safety of your power systems. From generator verification to renewable energy integration, its precision, versatility, and robust design make it an indispensable asset for engineers, technicians, and energy managers worldwide.

By integrating GROADA load banks into your maintenance and testing workflow, you ensure:

  • Enhanced system stability

  • Improved operational safety

  • Reliable performance under full-load conditions

Invest in the GROADA RLC Load Bank today and take control of your power system’s reliability and efficiency.