RLC Load Bank

GROADA-AC800V-851KW-RLC Load Bank Manufacturer

★★★★★
Main Products:
  • AC Load Bank : R / RL / RLC / RCD
  • DC Load Bank : DC5V - 2000V, 0A - 5000A


ModelAC220V-10KVA-RLCAC380V-30KVA-RLCAC380V-60KVA-RLCAC380V-100KVA-RLCAC380V-200KVA-RLCAC380V-300KVA-RLC
Rated powerRLC=10KVARLC=30KVARLC=60KVARLC=100KVARLC=200KVARLC=300KVA
R=10KW;L=10KVA
C=10KVA
R=30KW;L=30KVA;
C=30KVA
R=60KW;L=60KVA;
C=60KVA
R=100KW;L=100KVA;
C=100KVA
R=200KW;L=200KVA;
C=200KVA
R=300KW;L=300KVA;
C=300KVA
Other power can be customized according to requirements
Size (width * depth * height mm)500*750*1400600*850*15001000*1100*15001100*1600*15001500*1800*18002000*2000*2000
Weight120KG380KG580KG880KG1500KG2500KG
Input voltageAC220/230VAC380/400V
Other input voltage can be customized according to requirements
Input current0-45A0-45A0-90A0-150A0-300A0-450A
Minimum loadingR=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=1KW;L=1KVA;
C=1KVA
R=1KW;L=1KVA;
C=1KVA
Other minimum loading power can be customized according to requirements
power factorPF = 0.1~1.0 (other power factor can be customized according to requirements)
Overall accuracy3% (other accuracy requirements can be customized according to requirements)
Control modeLocal manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required)
Remote InterfaceRS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements)
Protection functionEmergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume)
Working power supplyAC220VAC220V/380VAC380V
Display accuracy0.5 level (other explicit precision can be customized according to requirements)
Display parametersVoltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements)
Cold sure waySide air inlet and upper air outlet (other air outlet methods can be customized according to requirements)
Protection levelIP20 (other protection level can be customized according to requirements)
Appearance colorRAL7035 (other colors can be customized according to requirements)
Working temperature-10 ℃ ~ 55 ℃
Relative humidity≤95%RH
Altitude≤ 2500 m


GROADA AC800V-851KW RLC Three-Phase AC Load Bank: Precision Power Testing for High-Voltage Systems

The GROADA AC800V-851KW RLC Three-Phase AC Load Bank represents the pinnacle of modern electrical testing solutions, designed to deliver precise, safe, and comprehensive load simulations for high-voltage power systems. Combining resistive (R), inductive (L), and capacitive (C) components, this load bank allows engineers and technicians to replicate real-world electrical conditions, ensuring that generators, UPS systems, and other critical infrastructure operate at peak reliability.


Key Features and Technical Specifications

  • Rated Power: 851 kW

  • Operating Voltage: 800V AC, three-phase, 50 Hz

  • Adjustable Power Factor: 0.1 to 1.0 (lagging and leading)

  • Load Resolution: 10 W for resistive, 10 VAR for inductive, 10 VAR for capacitive components

  • Control Interface: User-friendly local panel with remote monitoring capability

  • Cooling System: High-efficiency forced air cooling

  • Safety Mechanisms: Overload protection, temperature alarms, emergency stop

  • Compliance: Manufactured to meet international testing equipment standards


Applications

This versatile RLC load bank is ideal for multiple industries:

  • Power Generation: Validate and stress-test generators, transformers, and switchgear.

  • Data Centers: Ensure uninterrupted operation of UPS systems and emergency power backups.

  • Industrial Manufacturing: Test motors, large-scale machinery, and heavy-duty equipment.

  • Renewable Energy: Simulate grid conditions for solar, wind, and hybrid energy systems.

  • Telecommunications: Verify rectifiers and backup power solutions under dynamic loads.


Why RLC Load Banks Are Essential

In modern power systems, accurately simulating both active and reactive power is critical. RLC load banks replicate not only resistive loads but also inductive and capacitive effects, giving engineers the ability to evaluate voltage stability, harmonics, and power factor correction. This ensures long-term system reliability and prevents costly downtime.


Industry Insights

The global load bank market is experiencing robust growth, fueled by the expansion of power infrastructure, the rise of renewable energy, and increasing demand for reliable backup power. According to recent industry data, the market is projected to reach over USD 500 million by 2032, with RLC load banks representing a fast-growing segment due to their ability to mimic complex electrical loads and dynamic system behavior.


Why Choose GROADA?

  • Comprehensive Simulation: Accurately emulate real-world electrical loads for precise system evaluation.

  • High Precision: Advanced load control technology ensures reliable and repeatable test results.

  • Durable Design: Rugged construction designed to withstand industrial environments and long-term use.

  • Global Standard Compliance: Meets international standards, ensuring reliability across diverse markets.


Conclusion:
The GROADA AC800V-851KW RLC Three-Phase AC Load Bank is a crucial tool for engineers, data centers, industrial facilities, and power generation companies who demand high-precision, reliable, and safe electrical testing solutions. With its advanced RLC configuration, it not only supports routine load testing but also prepares your infrastructure for real-world operational challenges.