GROADA-AC220V-15KW-RLC Load Bank Manufacturer
The GROADA AC220V 15KW RLC Load Bank is engineered to provide comprehensive simulation of real-world...
| Model | AC220V-10KVA-RLC | AC380V-30KVA-RLC | AC380V-60KVA-RLC | AC380V-100KVA-RLC | AC380V-200KVA-RLC | AC380V-300KVA-RLC |
| Rated power | RLC=10KVA | RLC=30KVA | RLC=60KVA | RLC=100KVA | RLC=200KVA | RLC=300KVA |
| R=10KW;L=10KVA C=10KVA | R=30KW;L=30KVA; C=30KVA | R=60KW;L=60KVA; C=60KVA | R=100KW;L=100KVA; C=100KVA | R=200KW;L=200KVA; C=200KVA | R=300KW;L=300KVA; C=300KVA | |
| Other power can be customized according to requirements | ||||||
| Size (width * depth * height mm) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| Weight | 120KG | 380KG | 580KG | 880KG | 1500KG | 2500KG |
| Input voltage | AC220/230V | AC380/400V | ||||
| Other input voltage can be customized according to requirements | ||||||
| Input current | 0-45A | 0-45A | 0-90A | 0-150A | 0-300A | 0-450A |
| Minimum loading | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=1KW;L=1KVA; C=1KVA | R=1KW;L=1KVA; C=1KVA |
| Other minimum loading power can be customized according to requirements | ||||||
| power factor | PF = 0.1~1.0 (other power factor can be customized according to requirements) | |||||
| Overall accuracy | 3% (other accuracy requirements can be customized according to requirements) | |||||
| Control mode | Local manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required) | |||||
| Remote Interface | RS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements) | |||||
| Protection function | Emergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume) | |||||
| Working power supply | AC220V | AC220V/380V | AC380V | |||
| Display accuracy | 0.5 level (other explicit precision can be customized according to requirements) | |||||
| Display parameters | Voltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements) | |||||
| Cold sure way | Side air inlet and upper air outlet (other air outlet methods can be customized according to requirements) | |||||
| Protection level | IP20 (other protection level can be customized according to requirements) | |||||
| Appearance color | RAL7035 (other colors can be customized according to requirements) | |||||
| Working temperature | -10 ℃ ~ 55 ℃ | |||||
| Relative humidity | ≤95%RH | |||||
| Altitude | ≤ 2500 m | |||||
Ensure Optimal Performance, Reliability, and Safety Across Your Power Infrastructure
The GROADA AC380V 20KW RLC Load Bank is a high-performance testing solution designed for validating the reliability and efficiency of power generation and distribution systems. Combining resistive, inductive, and capacitive loads, it simulates real-world electrical conditions, enabling engineers and technicians to identify potential issues before they become critical failures.
Whether for generators, UPS systems, data centers, or renewable energy integration, this load bank delivers precise, repeatable, and safe testing results, ensuring your critical power systems operate at peak efficiency under any scenario.
Incorporates resistive (R), inductive (L), and capacitive (C) loads to accurately replicate the behavior of real electrical systems.
Allows precise simulation of different load types, including reactive and non-linear loads.
Supports a wide power factor range from 0.1 to 1.0, enabling testing under various operating conditions.
Critical for validating system performance in applications where reactive loads are present.
Modular architecture ensures easy scalability and allows customization based on specific testing needs.
Compact, robust, and transportable design ensures versatility in both field and laboratory environments.
Intuitive control panel provides real-time monitoring of voltage, current, power, and power factor.
Optional remote control functionality allows for safe operation from a distance.
Equipped with overload protection, short-circuit protection, and over-temperature alarms.
Ensures operator safety and prevents damage to both the load bank and tested equipment.
Simulates realistic load conditions to verify generator performance, efficiency, and reliability.
Ensures compliance with operational standards and minimizes the risk of failure during peak demand.
Tests UPS functionality under varied resistive, inductive, and capacitive loads.
Ensures backup power systems maintain reliability during outages.
Evaluates solar, wind, or hybrid power systems under dynamic load conditions.
Helps optimize inverter and storage system performance for consistent energy delivery.
Confirms that backup power systems and generators can handle high-demand, critical loads.
Prevents downtime and ensures business continuity.
The GROADA AC380V 20KW RLC Load Bank is designed to meet international safety and performance standards, ensuring both reliability and operational compliance:
IEEE 1547 – Standard for testing distributed energy resources.
NFPA 110 – Requirements for emergency and standby power systems.
ISO 8528-10 – Load acceptance testing standards for generating sets.
Compliance with these standards guarantees that the load bank can be safely and effectively integrated into professional power testing environments worldwide.
Reliability Assurance – Early detection of system weaknesses prevents critical failures.
Performance Optimization – Testing under real-world load conditions ensures generators, UPS units, and other systems perform efficiently.
Cost Efficiency – Proactive testing reduces costly emergency repairs and downtime.
Operational Confidence – Verifies that backup power systems are ready for emergency operation.
| Specification | Details |
|---|---|
| Rated Power | 20KW |
| Voltage | AC380V |
| Frequency | 50/60Hz |
| Power Factor | 0.1 – 1.0 |
| Control Mode | Local panel and optional remote |
| Safety Features | Overload, short circuit, over-temp alarms |
GROADA RLC Load Banks are trusted globally by power generation companies, data centers, and critical infrastructure operators. Our solutions are engineered for accuracy, durability, and ease of use, providing peace of mind for engineers and facility managers alike.
Email: groadacn@163.com
Phone: +86-755-23339096
Address: Shenzhen, Guangdong, China