GROADA-AC380V-550KW-R of generator resistance load bank
Generator resistance load box GROADA-AC380V-550KW-R_Shenzhen Guang Lu Da Electronics Co., Ltd. is a ...
| Model | AC220V-6KW-R | AC380V-30KW-R | AC380V-60KW-R | AC380V-100KW-R | AC380V-200KW-R | AC380V-400KW-R | AC380V-500KW-R | AC380V-1000KW-R |
| Rated power | 0-6KW | 0-30KW | 0-60KW | 0-100KW | 0-200KW | 0-400KW | 0-500KW | 0-1000KW |
| Size (width * depth * height mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Weight | 25KG | 80KG | 130KG | 180KG | 250KG | 550KG | 650KG | 1100KG |
| Input current | 0-30A | 0-45A | 0-90A | 0-150A | 0-300A | 0-600A | 0-750A | 0-1500A |
| Minimum loading | 100W | 100W | 500W | 1KW | 1KW | 5KW | 10KW | 50KW |
| Other minimum loading power can be customized according to requirements | ||||||||
| Input voltage | AC220/230V | AC380/400V | ||||||
| Other input voltage can be customized according to requirements | ||||||||
| Power | PF=1.0 | |||||||
| Overall accuracy | 3% (other accuracy requirements can be customized according to requirements) | |||||||
| Control mode | Local manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required) | |||||||
| Remote Interface | RS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements) | |||||||
| Protection function | Emergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume) | |||||||
| Working power supply | AC220V | AC220V/380V | AC380V | |||||
| Display accuracy | 0.5 level (other explicit precision can be customized according to requirements | |||||||
| Display parameters | Voltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements) | |||||||
| Cold sure way | Forward and out | Side air inlet and upper air outlet (other air outlet methods can be customized according to requirements) | ||||||
| Protection level | IP20 (other protection level can be customized according to requirements) | |||||||
| Appearance color | RAL7035 (other colors can be customized according to requirements) | |||||||
| Working temperature | -10 ℃ ~ 55 ℃ | |||||||
| Relative humidity | ≤95%RH | |||||||
| Altitude | ≤ 2500 m | |||||||
The GROADA-AC380V-550KW-R resistive load bank is engineered for precise and reliable testing of high-capacity generators, UPS systems, and industrial power equipment. With a full 550 kW output at 380V AC, this load bank delivers consistent, accurate loads, ensuring your power systems operate safely and efficiently under maximum stress conditions.
High Capacity Testing: Handle generator sets and power systems up to 550 kW with stable performance.
Precision Load Control: Advanced digital control allows fine-tuning of loads in real time, enabling accurate performance assessment.
Robust and Durable: Constructed with high-quality resistive elements and a sturdy enclosure to withstand rigorous industrial environments.
Enhanced Safety Measures: Integrated thermal protection, overload safeguards, and emergency stop mechanisms ensure operational safety.
User-Friendly Interface: Intuitive digital display and remote monitoring capabilities streamline testing processes.
The GROADA-AC380V-550KW-R is ideal for multiple industrial and commercial applications:
Generator Testing & Commissioning: Simulate full-load scenarios to verify generator output and stability.
UPS & Backup Power Systems: Confirm reliability and readiness of uninterruptible power supply systems.
Power Plant & Industrial Systems: Validate performance of high-capacity electrical installations.
Routine Maintenance: Periodic testing prolongs equipment lifespan and prevents unexpected downtime.
| Parameter | Specification |
|---|---|
| Model | GROADA-AC380V-550KW-R |
| Rated Voltage | 380V AC |
| Power Rating | 550 kW |
| Frequency | 50/60 Hz |
| Cooling Method | Forced Air |
| Control Interface | Digital display with remote monitoring |
| Safety Features | Overload protection, thermal shutdown, emergency stop |
Built in accordance with IEEE 1547, IEEE 112.3, and ISO 8528 standards, this load bank ensures reliable, repeatable testing for distributed energy systems, generators, and industrial power applications. Compliance guarantees that all tests meet global safety and performance regulations.
Maximized Equipment Longevity: Early detection of performance issues prevents costly failures.
Operational Reliability: Ensures power systems perform optimally under full load conditions.
Cost Efficiency: Minimizes downtime and maintenance costs with proactive testing.
Scalable Testing: Suitable for both medium and large-scale generators or industrial power systems.
Data Centers: Ensure uninterrupted operations for critical IT infrastructure.
Healthcare: Guarantee reliable backup power for hospitals and medical facilities.
Manufacturing & Industrial Plants: Maintain continuous production and energy reliability.
Telecommunications: Protect network uptime through rigorous power testing.
The GROADA-AC380V-550KW-R combines advanced engineering, industrial-grade reliability, and compliance with international standards. It is a trusted solution for companies seeking thorough, safe, and accurate power system testing.
Email: groada@163.com
Phone: +86 0755-23339096
Location: Shenzhen, Guangdong, China
Invest in the GROADA-AC380V-550KW-R load bank to ensure efficient, safe, and reliable power system performance. It is an essential tool for engineers and facility managers who demand precision and durability in power testing.