R Load Bank

GROADA-AC400V-1000KW-R High voltage resistor load bank

★★★★★
Main Products:
  • AC Load Bank : R / RL / RLC / RCD
  • DC Load Bank : DC5V - 2000V, 0A - 5000A


ModelAC220V-6KW-RAC380V-30KW-RAC380V-60KW-RAC380V-100KW-RAC380V-200KW-RAC380V-400KW-RAC380V-500KW-RAC380V-1000KW-R
Rated power0-6KW0-30KW0-60KW0-100KW0-200KW0-400KW0-500KW0-1000KW
Size (width * depth * height mm)480*600*277500*750*1000600*850*1000600*850*1400700*1000*16501100*1400*17001100*1400*18001500*1800*2000
Weight25KG80KG130KG180KG250KG550KG650KG1100KG
Input current0-30A0-45A0-90A0-150A0-300A0-600A0-750A0-1500A
Minimum loading100W100W500W1KW1KW5KW10KW50KW
Other minimum loading power can be customized according to requirements
Input voltageAC220/230VAC380/400V
Other input voltage can be customized according to requirements
PowerPF=1.0
Overall accuracy3% (other accuracy requirements can be customized according to requirements)
Control modeLocal manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required)
Remote InterfaceRS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements)
Protection functionEmergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume)
Working power supplyAC220VAC220V/380VAC380V
Display accuracy0.5 level (other explicit precision can be customized according to requirements
Display parametersVoltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements)
Cold sure wayForward and outSide air inlet and upper air outlet (other air outlet methods can be customized according to requirements)
Protection levelIP20 (other protection level can be customized according to requirements)
Appearance colorRAL7035 (other colors can be customized according to requirements)
Working temperature-10 ℃ ~ 55 ℃
Relative humidity≤95%RH
Altitude≤ 2500 m



GROADA AC400V-1000KW-R Resistive Load Bank: High-Power, Reliable, and Precise Load Testing Solution

Overview

The GROADA AC400V-1000KW-R Resistive Load Bank is a high-performance electrical testing solution designed for large-scale power systems. Built with precision engineering and advanced safety features, this load bank allows engineers and technicians to accurately simulate electrical loads, ensuring that generators, UPS systems, and other power equipment perform reliably under real-world conditions.

Ideal for both indoor and outdoor use, the AC400V-1000KW-R model is engineered to deliver consistent, safe, and repeatable results across a wide range of applications in industrial, commercial, and renewable energy sectors.


Key Features and Benefits

1. High Power Capacity

  • Capable of delivering 1000 kW of resistive load at 400V AC, making it suitable for testing high-capacity generators and large electrical systems.

  • Supports both continuous and intermittent load testing, ensuring flexibility for different testing scenarios.

2. Precision Load Control

  • Features finely segmented load steps, enabling precise simulation of electrical loads from minimal to maximum capacity.

  • Facilitates accurate power factor and efficiency analysis, helping optimize generator and UPS performance.

3. Robust and Durable Construction

  • Designed with a weather-resistant steel enclosure for long-lasting performance in harsh industrial environments.

  • High-quality resistive elements ensure stable heat dissipation, preventing overheating during extended testing periods.

4. Advanced Digital Monitoring

  • Equipped with intuitive control panels displaying real-time voltage, current, power, and energy consumption.

  • Allows operators to monitor system performance and adjust loads dynamically for thorough testing and diagnostics.

5. Safety-First Design

  • Integrated overcurrent protection, thermal cutoff, and emergency shutdown functions to safeguard both equipment and personnel.

  • Ensures compliance with international electrical safety standards, providing peace of mind during high-power testing operations.


Applications Across Industries

The AC400V-1000KW-R Resistive Load Bank is versatile, addressing the growing demand for reliable power testing across multiple industries:

  1. Generator Testing

    • Validates the capacity, efficiency, and operational stability of backup and prime power generators.

    • Supports predictive maintenance programs by identifying potential performance issues before deployment.

  2. UPS and Energy Storage Systems

    • Tests uninterruptible power supply systems under varying loads to ensure reliability during outages.

    • Assists in verifying energy storage integration in critical facilities such as data centers and hospitals.

  3. Data Center and Mission-Critical Facilities

    • Ensures uninterrupted operations by simulating peak loads for server rooms and networking equipment.

    • Helps optimize power distribution and cooling systems for maximum efficiency.

  4. Renewable Energy and Grid Integration

    • Supports testing for solar inverters, wind generators, and hybrid power systems.

    • Evaluates performance under variable load conditions to confirm grid compatibility and stability.

  5. Industrial and Commercial Power Systems

    • Assesses high-capacity motors, compressors, and industrial machinery under full-load conditions.

    • Reduces risk of unexpected downtime by verifying electrical infrastructure before operation.


Industry Insights and Market Trends

The global load bank market is projected to grow steadily, driven by the increasing complexity and critical nature of power systems in various sectors. According to industry research:

  • The market is expected to rise from $300 million in 2025 to over $380 million by 2032, reflecting a growing demand for reliable power testing solutions.

  • Key drivers include the expansion of data centers, renewable energy integration, and stricter compliance requirements for mission-critical facilities.

  • Advanced digital load banks, like the GROADA AC400V-1000KW-R, are increasingly preferred due to their enhanced precision, real-time monitoring, and improved safety standards.


Why Choose GROADA?

GROADA is recognized as a leading innovator in load bank technology, combining decades of engineering expertise with cutting-edge manufacturing. By choosing the AC400V-1000KW-R Resistive Load Bank, customers benefit from:

  • Unmatched reliability: Built to withstand demanding industrial conditions.

  • High accuracy: Fine-tuned load control for precise power testing.

  • Comprehensive support: Technical guidance and global after-sales service for seamless operation.

  • Industry compliance: Designed to meet international safety and electrical standards.

This makes GROADA a trusted partner for engineers, power system operators, and facility managers worldwide, ensuring that critical electrical systems perform at their best.


Technical Specifications (Summary)

  • Voltage: 400V AC

  • Power Capacity: 1000 kW

  • Load Type: Resistive

  • Load Steps: Fine-grained, adjustable

  • Cooling: Forced air / high-efficiency heat dissipation

  • Control: Digital display and intuitive interface

  • Safety: Overcurrent protection, thermal shutdown, emergency stop


Conclusion

The GROADA AC400V-1000KW-R Resistive Load Bank is more than just a testing device; it is a comprehensive solution for modern power system verification and reliability assurance. Its combination of high power capacity, precision control, safety features, and durability makes it an indispensable tool for power engineers and facility managers aiming for optimal system performance, efficiency, and longevity.