GROADA-AC380V-550KW-R of generator resistance load bank
Generator resistance load box GROADA-AC380V-550KW-R_Shenzhen Guang Lu Da Electronics Co., Ltd. is a ...
| Model | AC220V-6KW-R | AC380V-30KW-R | AC380V-60KW-R | AC380V-100KW-R | AC380V-200KW-R | AC380V-400KW-R | AC380V-500KW-R | AC380V-1000KW-R |
| Rated power | 0-6KW | 0-30KW | 0-60KW | 0-100KW | 0-200KW | 0-400KW | 0-500KW | 0-1000KW |
| Size (width * depth * height mm) | 480*600*277 | 500*750*1000 | 600*850*1000 | 600*850*1400 | 700*1000*1650 | 1100*1400*1700 | 1100*1400*1800 | 1500*1800*2000 |
| Weight | 25KG | 80KG | 130KG | 180KG | 250KG | 550KG | 650KG | 1100KG |
| Input current | 0-30A | 0-45A | 0-90A | 0-150A | 0-300A | 0-600A | 0-750A | 0-1500A |
| Minimum loading | 100W | 100W | 500W | 1KW | 1KW | 5KW | 10KW | 50KW |
| Other minimum loading power can be customized according to requirements | ||||||||
| Input voltage | AC220/230V | AC380/400V | ||||||
| Other input voltage can be customized according to requirements | ||||||||
| Power | PF=1.0 | |||||||
| Overall accuracy | 3% (other accuracy requirements can be customized according to requirements) | |||||||
| Control mode | Local manual/remote host computer (local manual control mode: circuit breaker/button/touch screen three-way optional, other methods can be customized as required) | |||||||
| Remote Interface | RS232/RS485/USB/RJ45/CAN/GPIB (other interface modes can be customized according to requirements) | |||||||
| Protection function | Emergency stop protection, over-temperature protection, fan load interlock protection, grounding protection (select over-voltage protection, over-current protection, short-circuit protection, fan overload, insufficient air volume) | |||||||
| Working power supply | AC220V | AC220V/380V | AC380V | |||||
| Display accuracy | 0.5 level (other explicit precision can be customized according to requirements | |||||||
| Display parameters | Voltage, current, power, frequency, power factor, etc. (other explicit methods can be customized according to requirements) | |||||||
| Cold sure way | Forward and out | Side air inlet and upper air outlet (other air outlet methods can be customized according to requirements) | ||||||
| Protection level | IP20 (other protection level can be customized according to requirements) | |||||||
| Appearance color | RAL7035 (other colors can be customized according to requirements) | |||||||
| Working temperature | -10 ℃ ~ 55 ℃ | |||||||
| Relative humidity | ≤95%RH | |||||||
| Altitude | ≤ 2500 m | |||||||
Reliable Power Testing Solution for Industrial and Commercial Applications
The GROADA-AC400V-200KW-R Resistive Load Bank is meticulously engineered to simulate real-world electrical loads, ensuring your power systems operate efficiently and reliably. This high-capacity load bank is essential for testing generators, uninterruptible power supplies (UPS), turbines, and battery systems, providing precise resistive loads under controlled conditions.
High-Precision Load Simulation: Provides stable resistive loads to accurately test the performance and efficiency of power sources.
Modular and Scalable Design: Easily adjustable for different testing scenarios, allowing multiple load banks to be connected in parallel.
Advanced Monitoring Interface: Digital display and intuitive controls allow real-time monitoring of voltage, current, and power levels.
Robust Construction: Industrial-grade materials ensure durability and long-term operation in demanding environments.
Efficient Cooling System: Forced-air cooling prevents overheating, extending the lifespan of components.
Flexible Voltage Compatibility: Designed for 400V AC systems, suitable for both 50Hz and 60Hz applications.
| Specification | Details |
|---|---|
| Model | AC400V-200KW-R |
| Power Capacity | 200 kW |
| Input Voltage | 400V AC |
| Frequency | 50/60 Hz |
| Load Steps | 1 kW increments |
| Cooling Method | Forced air |
| Protection Class | IP20 |
| Dimensions (L×W×H) | 800 × 600 × 1000 mm |
| Weight | 150 kg |
Power Generation: Ensures generators perform at peak efficiency before commissioning.
UPS Systems: Validates reliability of critical backup power infrastructure.
Turbines & Industrial Equipment: Assesses system performance under variable loads.
Battery & Energy Storage Testing: Measures capacity and discharge efficiency.
EVSE & Inverter Testing: Provides safe and precise resistive loads for advanced power electronics.
The global load bank market is expanding rapidly, driven by the demand for reliable power infrastructure and industrial testing solutions. Recent industry data shows:
Global Market Value: Estimated at USD 200 million in 2023, projected to grow to USD 350 million by 2032 (CAGR ~6%).
Resistive Load Bank Segment: Expected to exceed USD 168 million by 2033, highlighting its essential role in modern power testing.
Adoption is fueled by the increasing deployment of UPS, renewable energy systems, and advanced industrial generators worldwide.
GROADA is a leading provider of high-quality load banks, recognized for precision, reliability, and innovation. The AC400V-200KW-R model embodies our commitment to excellence, delivering dependable and accurate testing solutions that meet international standards. By choosing GROADA, you ensure:
Unmatched product reliability
Advanced load testing technology
Expert customer support and guidance
The GROADA-AC400V-200KW-R Resistive Load Bank is the ideal choice for industrial, commercial, and renewable energy applications. Its precision, modularity, and robust construction make it a versatile solution for testing and validating critical power systems, providing peace of mind and operational confidence for engineers and facility managers alike.