GROADA-AC120V-5KW-RCD负载组制造商
The GROADA AC120V-5KW RCD Load Bank is a high-precision testing device designed to simulate nonlinea...
| 模型 | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380V-30KW-RCD | AC380V-50KW-RCD | AC380V-60KW-RCD | AC380V-100KW-RCD | AC380V-200KW-RCD |
| 额定功率 | R=5KW | R=10KW | R=15KW | R=20KW | R=30KW | R=50KW | R=60KW | R=100KW | R=200KW |
| RCD=5KVA | RCD=10KVA | RCD=15KVA | RCD=20KVA | RCD=30KVA | RCD=50KVA | RCD=60KVA | RCD=100KVA | RCD=200KVA | |
| 输入电流 | 0-22A | 0-45A | 0-45A | 0-90A | 0-45A | 0-3:00 | 0-450A | 0-600A | 0-750A |
| 尺寸(宽*深*高mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| 重量 | 50KG | 80公斤 | 100公斤 | 130公斤 | 200KG | 300公斤 | 350公斤 | 450公斤 | 550公斤 |
| 输入电压 | 交流220/230V | 交流380/400V | |||||||
| 其他输入电压可根据要求定制 | |||||||||
| 最小载荷 | 100W | 100W | 100W | 100W | 100W | 1千瓦 | 1千瓦 | 1千瓦 | 1千瓦 |
| 其他最小负载功率可根据要求定制 | |||||||||
| 整体精度 | 3%(其他精度要求可根据要求定制) | ||||||||
| 功率因数 | PF=0.6~1.0 | ||||||||
| 峰形系数 | 2至3 | ||||||||
| 控制模式 | 本地手动/远程主机(本地手动控制模式:断路器/按钮/触摸屏三路可选,其他方法可根据需要定制) | ||||||||
| 远程接口 | RS232/RS485/USB/RJ45/CAN/GPIB(其他接口模式可根据要求定制) | ||||||||
| 保护功能 | 紧急停机保护、超温保护、风机负载联锁保护、接地保护(选择过压保护、过流保护、短路保护、风机超负荷、风量不足) | ||||||||
| 工作电源 | AC220V | AC220V/AC380V | |||||||
| 显示精度 | 0.5级(其他显式精度可根据要求定制) | ||||||||
| 显示参数 | 电压、电流、功率、频率、功率因数等。(其他显式方法可根据要求定制) | ||||||||
| 冷肯定的方式 | 侧进风口和上出风口(其他出风口方式可根据要求定制) | ||||||||
| 保护级别 | IP20(其他防护等级可根据要求定制) | ||||||||
| 外观颜色 | RAL7035(其他颜色可根据要求定制) | ||||||||
| 工作温度 | -10 ℃ ~ 55 ℃ | ||||||||
| 相对湿度 | ≤95%相对湿度 | ||||||||
| 高度 | ≤2500米 | ||||||||
这GROADA AC220V 40kW RCD负载组是一种最先进的测试设备,旨在模拟复杂的电阻、电容和电感负载。它为电力系统工程师和设施管理人员提供了一种可靠的解决方案,用于在现实操作条件下验证系统性能、稳定性和弹性。该负载组非常适合UPS系统、逆变器、发电机、数据中心和其他关键基础设施,确保不间断运行和最佳电能质量。
| 特性 | 规格说明 |
|---|---|
| 额定功率 | 40kW |
| 电压 | 交流220V |
| 负载类型 | RCD(电阻式、电容式、电感式) |
| 功率因数范围 | 0.6 – 1.0 |
| 频率 | 50/60赫兹 |
| 最大电流 | 180A |
| 冷却方法 | Forced Air Cooling |
| 控制界面 | Advanced Touchscreen with Real-Time Monitoring |
| 安全功能 | Overload Protection, RCD Protection, Emergency Shutdown |
这RCD load configuration allows precise simulation of nonlinear electrical loads, enabling engineers to test how systems behave under realistic conditions. Its high-current capacity and adjustable power factor ensure flexibility in testing a wide range of equipment.
The GROADA AC220V 40kW RCD Load Bank is engineered for versatility across multiple industries:
UPS Systems Testing
Evaluate uninterruptible power supplies under varying load conditions to ensure they can handle dynamic energy demands and maintain output stability.
Inverter Performance Validation
Test inverters in renewable energy setups and industrial environments to measure response under non-linear loads.
Data Center Power Resilience
Simulate realistic IT load profiles to verify critical infrastructure can sustain operations during peak and fluctuating demand.
发电机负载测试
Accurately simulate complex load patterns to ensure standby and emergency generators operate reliably under non-linear conditions.
Industrial Power Systems
Analyze the impact of resistive, inductive, and capacitive loads on industrial motor drives, switchgear, and electrical distribution systems.
The GROADA RCD Load Bank is built to meet global industry standards, ensuring safe, accurate, and reliable testing:
IEEE 1547 – Interconnection of distributed resources with electric power systems
NFPA 110 – Emergency and standby power system standards
ISO 8528-10 – Load acceptance procedures for generating sets
IEC 62040 – Performance and testing requirements for uninterruptible power systems
These certifications reflect the highest level of reliability, safety, and industry compliance, making it suitable for both commercial and industrial applications.
The load bank’s advanced design allows for in-depth testing scenarios:
Dynamic Load Simulation
Test power systems’ response to rapid load changes, simulating real-life operational conditions.
Harmonic Distortion Analysis
Evaluate how non-linear loads affect voltage quality, equipment performance, and system efficiency.
Transient Response Testing
Assess system stability during sudden changes, ensuring critical power systems maintain operational continuity.
Comprehensive Load Management
Adjust resistive, inductive, and capacitive components independently to replicate a wide range of load behaviors.
精确负载模拟 – Accurately replicates real-world nonlinear electrical loads for comprehensive system testing.
用户友好界面 – Intuitive touchscreen control with real-time monitoring simplifies operations and improves testing efficiency.
Robust Safety Mechanisms – Integrated protections safeguard both personnel and equipment during rigorous testing.
Versatile Industrial Applications – Suitable for data centers, renewable energy, industrial plants, and more.
Global Standards Compliance – Provides assurance of testing reliability and performance consistency across regions.
Investing in the GROADA RCD Load Bank ensures your critical power systems are rigorously tested, optimized, and ready for reliable operation under complex electrical loads. It is an indispensable tool for engineers, technicians, and facility managers seeking accuracy, safety, and efficiency in power system evaluation.