GROADA-AC346V-50KVA-RL阻感性负载组
GROADA AC346V-50KVA RL AC Load Bank is a high-precision resistive-inductive (RL) load cabinet design...
| 模型 | AC220V-10KVA-RL | AC380V-30KVA-RL | AC380V-60KVA-RL | AC380V-100KVA-RL | AC380V-300KVA-RL | AC380V-500KVA-RL | AC380V-1000KVA-RL |
| 额定功率 | RL=10KVA | RL=30KVA | RL=60KVA | RL=100KVA | RL=300KVA | RL=500KVA | RL=1000KVA |
| R=10KW;L=6KVA | R=30KW;L=18KVA | R=60KW;L=36KVA | R=100KW;L=60KVA | R=300KW;L=180KVA | R=500KW;L=300KVA | R=1000KW;L=600KVA | |
| 输入电流 | 0-45A | 0-45A | 0-90A | 0-150A | 0-450A | 0-750A | 0-1500A |
| 尺寸(宽*深*高mm) | 480*600*277 | 480*600*360 | 500*750*1000 | 600*850*1000 | 700*1000*1650 | 1100*1400*1700 | 1100*1500*1900 |
| 重量 | 25公斤 | 40公斤 | 80公斤 | 130公斤 | 250公斤 | 550公斤 | 750公斤 |
| 最小载荷 | 100W | 100W | 100W | 500W | 1千瓦 | 5KW | 10KW |
| 其他最小负载功率可根据要求定制 | |||||||
| 输入电压 | 交流220/230V | 交流380/400V | |||||
| 其他输入电压可根据要求定制 | |||||||
| 功率因数 | PF=0.8/1.0(其他功率因数可根据要求定制) | ||||||
| 整体精度 | 3%(其他精度要求可根据要求定制) | ||||||
| 控制模式 | 本地手动/远程主机(本地手动控制模式:断路器/按钮/触摸屏三路可选,其他方法可根据需要定制) | ||||||
| 远程接口 | RS232/RS485/USB/RJ45/CAN/GPIB(其他接口模式可根据要求定制) | ||||||
| 保护功能 | 紧急停机保护、超温保护、风机负载联锁保护、接地保护(选择过压保护、过流保护、短路保护、风机超负荷、风量不足) | ||||||
| 工作电源 | AC220V | 交流220V/380V | 交流380v | ||||
| 显示精度 | 0.5级(其他显式精度可根据要求定制) | ||||||
| 显示参数 | 电压、电流、功率、频率、功率因数等。(其他显式方法可根据要求定制) | ||||||
| 冷肯定的方式 | 侧进风口和上出风口(其他出风口方式可根据要求定制) | ||||||
| 保护级别 | IP20(其他防护等级可根据要求定制) | ||||||
| 外观颜色 | RAL7035(其他颜色可根据要求定制) | ||||||
| 工作温度 | -10 ℃ ~ 55 ℃ | ||||||
| 相对湿度 | ≤95%相对湿度 | ||||||
| 高度 | ≤2500米 | ||||||
GROADA AC346V-50KVA RL交流负载组是一种高精度电阻-电感(RL)负载柜设计用于测试和验证电力设备,如发电机、UPS系统、逆变器、数据中心和工业电源.
此模型支持精确的功率因数调整(0.8滞后至0.8领先)模块化扩展、先进的冷却设计和智能保护机制,确保在要求苛刻的应用中性能稳定可靠。
额定功率:50千伏安
额定电压:346 V交流电(可定制380 V/400 V/415 V)
负载类型:电阻+电感
可调功率因数:0.8滞后~1.0~0.8领先
模块化设计:可通过并联进行扩展
冷却:高效强制空气冷却
保护:过载、过热、短路、风扇故障报警
控制与;沟通:手动面板+RS-485/Modbus/以太网远程监控
应用:发电厂、发电机测试、UPS老化测试、可再生能源系统、电动汽车充电站
| 参数 | 价值 |
|---|---|
| 额定功率 | 50千伏安 |
| 电压范围 | 300–380 V交流电(自定义选项) |
| 负载类型 | 电阻+电感(RL) |
| 功率因数调整 | 0.8滞后~1.0~0.8领先 |
| 冷却系统 | 强制风冷,顶部排气 |
| 保护功能 | Overload / Overheat / Short circuit / Fan failure |
| 控制模式 | Manual local control + Remote monitoring |
| Communication Protocols | RS-485 / Modbus / Ethernet |
| Cabinet Design | Rugged enclosure, IP protection customizable |
| Working Temperature | –10℃ ~ +45℃ |
The load bank integrates resistive elements and inductive coils in modular sections.
Load Control: PWM control enables precise step adjustment of load capacity.
Power Factor Simulation: Supports real-time adjustment to simulate inductive and capacitive conditions.
Protection Mechanism: Temperature sensors, fan monitoring, automatic unloading in case of fault.
冷却系统: High-volume fans ensure fast heat dissipation and safe operation under full load.
Smart Monitoring: Remote control and data logging via Modbus or Ethernet.
发电: Testing diesel / gas generators under full load and transient conditions.
不间断电源系统: Long-time aging tests and reliability verification.
可再生能源: Grid-tie inverter and photovoltaic system validation.
数据中心: Simulating real IT load for facility acceptance.
EV Charging Stations: Power electronics and charging infrastructure testing.
Compared with traditional load banks, GROADA AC load banks deliver:
Higher accuracy in power factor adjustment.
Better thermal management with forced air cooling.
Modular and expandable architecture for flexible capacity.
Advanced safety protections ensuring long service life.
Remote monitoring & control for modern test environments.
When choosing a load bank:
额定功率 ≥ 1.2 × tested equipment rated power.
Voltage Level must match system (300–380V standard, custom for 400/415/480V).
功率因数: choose RL load bank if your DUT (device under test) involves inductive / capacitive behaviors.
Environment: outdoor use requires higher IP protection and enhanced cooling.
Q1: Can the load bank run continuously at full power?
Yes, with proper ventilation, it can sustain continuous full-load operation.
Q2: How often should maintenance be performed?
Every 6–12 months: check fans, wiring terminals, resistance modules, and clean dust.
Q3: Does it support remote monitoring?
Yes, via RS-485 / Modbus / Ethernet for data logging, alarm, and control.
Q4: What protection functions are included?
Overload, overheat, short-circuit, and fan failure detection with automatic load disconnection.
ISO 9001 / ISO 14001 certified manufacturer
CE / UL compliance (upon request)
Factory type test reports available (temperature rise, EMC, insulation, durability)
Warranty: 12 months, with global technical support
“We deployed GROADA RL load banks for generator testing in our European facility. The precision and stability exceeded expectations.” — John M., Germany
“Reliable partner for UPS verification projects. Remote monitoring makes operation much easier.” — David P., UK
📩 Email: groada@163.com
☎ Phone: +86 13342997981
📍 Address: Shenzhen, China
👉 Request a Quote or Free Consultation today!