模型AC220V-10KVA-RLCAC380V-30KVA-RLCAC380V-60KVA-RLCAC380V-100KVA-RLCAC380V-200KVA-RLCAC380V-300KVA-RLC
额定功率RLC=10KVARLC=30KVARLC=60KVARLC=100KVARLC=200KVARLC=300KVA
R=10KW;L=10KVA
C=10KVA
R=30KW;L=30KVA;
C=30KVA
R=60KW;L=60KVA;
C=60KVA
R=100KW;L=100KVA;
C=100KVA
R=200KW;L=200KVA;
C=200KVA
R=300KW;L=300KVA;
C=300KVA
其他电源可根据要求定制
尺寸(宽*深*高mm)500*750*1400600*850*15001000*1100*15001100*1600*15001500*1800*18002000*2000*2000
重量120公斤380公斤580公斤880公斤1500公斤2500公斤
输入电压交流220/230V交流380/400V
其他输入电压可根据要求定制
输入电流0-45A0-45A0-90A0-150A0-3:000-450A
最小载荷R=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=100W;L=100VA;
C=100VA
R=1KW;L=1KVA;
C=1KVA
R=1KW;L=1KVA;
C=1KVA
其他最小负载功率可根据要求定制
功率因数PF=0.1~1.0(其他功率因数可根据要求定制)
整体精度3%(其他精度要求可根据要求定制)
控制模式本地手动/远程主机(本地手动控制模式:断路器/按钮/触摸屏三路可选,其他方法可根据需要定制)
远程接口RS232/RS485/USB/RJ45/CAN/GPIB(其他接口模式可根据要求定制)
保护功能紧急停机保护、超温保护、风机负载联锁保护、接地保护(选择过压保护、过流保护、短路保护、风机超负荷、风量不足)
工作电源AC220V交流220V/380V交流380v
显示精度0.5级(其他显式精度可根据要求定制)
显示参数电压、电流、功率、频率、功率因数等。(其他显式方法可根据要求定制)
冷肯定的方式侧进风口和上出风口(其他出风口方式可根据要求定制)
保护级别IP20(其他防护等级可根据要求定制)
外观颜色RAL7035(其他颜色可根据要求定制)
工作温度-10 ℃ ~ 55 ℃
相对湿度≤95%相对湿度
高度≤2500米


GROADA AC415V-36KW RLC Load Bank – Precision Testing for Reliable Power Systems

GROADA AC415V-36KW RLC Load Bank is a cutting-edge, three-phase load testing solution engineered for the most demanding applications in power generation, industrial automation, renewable energy, and critical infrastructure systems. Combining resistive (R), inductive (L), and capacitive (C) loads in a single, high-performance unit, it provides comprehensive and precise simulation of real-world electrical conditions.


主要特点

  • Tri-Load Capability: Simulates resistive, inductive, and capacitive loads to replicate diverse operating scenarios.

  • High Precision: Fine-tuned load regulation ensures outputs closely mirror real power consumption and reactive characteristics.

  • Safe and Reliable: Integrated protection against overcurrent, short circuit, overheating, and fan failures.

  • 坚固的结构: Air-cooled design ensures efficient heat dissipation, even during prolonged operation.

  • Flexible Control: Local control panel with optional remote operation allows for versatile testing environments.


技术规格

规格说明详情
额定功率36 kW
额定电压AC 415V, 3-phase, 4-wire
控制模式Local panel control with optional remote control
负载调整率Fine adjustment for precise load application
保护特性Overcurrent, overload, over-temperature, fan failure alarms
CoolingAir-cooled for high-efficiency heat dissipation

Why Choose GROADA RLC Load Banks?

综合负载模拟

  • Resistive Load (R): Ideal for evaluating generators, UPS systems, and other power sources under real energy consumption.

  • Inductive Load (L): Accurately simulates motors, transformers, and reactive loads for power factor and stability testing.

  • Capacitive Load (C): Supports leading power factor conditions to test systems with power factor correction and energy storage integration.

Industry-Leading Precision

The load bank offers precise step adjustments, ensuring each testing scenario closely matches actual operational conditions. This accuracy is critical for predictive maintenance, system validation, and compliance testing.

Safety and Durability

Engineered for industrial environments, the GROADA AC415V-36KW RLC Load Bank includes multiple layers of protection. Its rugged chassis, reliable cooling, and fail-safe design reduce downtime and safeguard both equipment and operators.


Industry Applications

  • Data Centers: Test backup generators and UPS systems under real-world loads.

  • Telecommunications: Ensure uninterrupted power and stability for mission-critical networks.

  • Renewable Energy Integration: Validate solar, wind, and hybrid systems with reactive load testing.

  • Industrial Power Systems: Confirm generator performance, load distribution, and electrical system stability.

  • Electric Vehicle Infrastructure: Simulate complex load profiles for EV chargers and energy storage systems.


Market Insight

The global RLC load bank market is expanding rapidly due to the increasing need for reliable, high-performance power systems. Industries including data centers, renewable energy, industrial automation, and EV infrastructure are driving demand. As organizations prioritize energy efficiency, safety, and compliance with power standards, high-precision load banks like the GROADA AC415V-36KW become essential tools.

Three-phase systems dominate the market, with growing adoption in industrial and commercial facilities worldwide. By choosing GROADA, customers gain access to a solution that meets rigorous industry standards and ensures long-term operational reliability.


Advantages of GROADA Load Banks

  • Versatile Testing: Supports resistive, inductive, and capacitive load testing in one unit.

  • Precision Control: Fine adjustments for accurate load simulation.

  • Robust Safety: Protects both the operator and connected systems.

  • Energy Efficient: Air-cooled design for prolonged and safe operation.

  • Industry Compliant: Meets global standards for load testing in critical applications.