GROADA-AC346V-50KVA-RL抵抗感性負荷バンク
GROADA AC346V-50KVA RL AC Load Bank is a high-precision resistive-inductive (RL) load cabinet design...
| モデル | AC220V-10KVA-RLC | AC380V-30KVA-RLC | AC380V-60KVA-RLC | AC380V-100KVA-RLC | AC380V-200KVA-RLC | AC380V-300KVA-RLC |
| 評価パワー | RLC=10KVA | RLC=30KVA | RLC=60KVA | RLC=100KVA | RLC=200KVA | RLC=300KVA |
| R=10KW;L=10KVA C=10KVA | R=30KW;L=30KVA; C=30KVA | R=60KW;L=60KVA; C=60KVA | R=100KW;L=100KVA; C=100KVA | R=200KW;L=200KVA; C=200KVA | R=300KW;L=300KVA; C=300KVA | |
| 他の力は条件に従ってカスタマイズすることができます | ||||||
| サイズ(幅*深さ*高さmm) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| 重量 | 120キログラム | 380キログラム | 580キログラム | 880キログラム | 1500キログラム | 2500キログラム |
| 入力電圧 | AC220/230V | AC380/400V | ||||
| 他の入力電圧は条件に従ってカスタマイズできます | ||||||
| 入力電流 | 0〜45A | 0〜45A | 0-90A | 0〜150A | 0〜300A | 0-450A |
| 最小負荷 | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=100W;L=100VA; C=100VA | R=1KW;L=1KVA; C=1KVA | R=1KW;L=1KVA; C=1KVA |
| 他の最低負荷力は条件に従ってカスタマイズすることができます | ||||||
| パワーファクター | PF = 0.1~1.0(他のパワー要因は条件に従ってカスタマイズすることができます) | |||||
| 全体的な精度 | 3%(他の正確さの条件は条件に従ってカスタマイズすることができます) | |||||
| 制御モード | ローカルマニュアル/リモートホストコンピュータ(ローカルマニュアル制御モード:ブレーカー/ボタン/タッチスクリーン三向任意、他の方法は必要に応じてカスタマイズすることができます) | |||||
| リモートインターフェース | RS232/RS485/USB/RJ45/CAN/GPIB(他のインターフェースモードは条件に応じてカスタマイズすることができます) | |||||
| 保護機能 | 緊急停止保護,過熱保護,ファン負荷インターロック保護,接地保護 (過電圧保護,過電流保護,短回路保護,ファン過負荷,空気量不足を選択) | |||||
| 働く電源 | AC220V の | AC220V/380V | AC380V の | |||
| 表示精度 | 0.5レベル(他の明確な精度は条件に従ってカスタマイズすることができます) | |||||
| 表示パラメータ | 電圧、電流、力、周波数、パワー要因等 (他の明示的な方法は条件に従ってカスタマイズすることができます) | |||||
| 冷たい確かな方法 | 側面の空気入口および上の空気出口(他の空気出口方法は条件に応じてカスタマイズすることができます) | |||||
| 保護レベル | IP20(他の保護レベルは条件に従ってカスタマイズすることができます) | |||||
| 外観色 | RAL7035(他の色は条件に従ってカスタマイズすることができます) | |||||
| 作業温度 | -10 ℃ ~ 55 ℃ | |||||
| 相対湿度 | ≤95%RH | |||||
| 高さ | ≤ 2500 m | |||||
「 TheGROAD 1068 AC Load Bank represents the pinnacle of electrical load testing technology, engineered for industries where power reliability and operational efficiency are mission-critical. Designed to simulate real-world electrical loads, it ensures that generators, transformers, UPS systems, and other critical power equipment perform flawlessly under full load conditions. Whether for industrial applications, data centers, or renewable energy integration, the GROAD 1068 is the ultimate solution for comprehensive power system validation.
High-Capacity Load Simulation
Capable of handling substantial resistive and reactive loads, the GROAD 1068 can accurately replicate real operational conditions, providing engineers with reliable insights into system performance and efficiency.
Advanced Digital Control Interface
Equipped with an intuitive LCD digital control system, the load bank allows for precise load adjustments, real-time monitoring, and detailed data logging. Operators can track voltage, current, and power metrics to ensure accurate testing.
Versatility Across Applications
Suitable for testing generators, transformers, UPS systems, and emergency backup power solutions, the 1068 model adapts to a wide range of power infrastructures, making it indispensable for industrial, commercial, and critical mission applications.
堅固で耐久的な構造
Built from premium materials, the unit is designed for long-term durability, even under continuous heavy load testing, minimizing downtime and maintenance requirements.
The GROAD 1068 AC Load Bank is tailored to industries and environments where power stability and reliability cannot be compromised:
発電 – Validate the performance and efficiency of generators under peak load conditions to prevent system failures.
データセンター – Ensure UPS and backup generators operate seamlessly to maintain uninterrupted operations.
産業製造 – Test power systems supporting critical processes to avoid costly downtime.
再生可能エネルギーシステム – Evaluate the integration of solar, wind, and hybrid energy systems with conventional power grids.
| 特徴 | 仕様 |
|---|---|
| 負荷タイプ | Resistive / Reactive |
| 電圧 | 380V ±10% |
| 周波数 | 50/60Hz |
| 冷却方法 | 空気冷却 |
| Control System | Digital LCD display with precise load control |
| 保護特徴 | Overload, short-circuit, over-temperature protection |
| コンプライアンス基準 | ISO 9001, CE, RoHS |
「 Theglobal AC load bank market is experiencing significant growth, driven by the rising demand for reliable power testing solutions. Forecasts project the market to exceed $350 million by 2032, with a CAGR of approximately 6.5% from 2024 to 2032.
Key factors driving this growth include:
データセンター拡張 – The surge in cloud computing and big data requires robust power infrastructure, increasing demand for high-quality load testing.
再生可能エネルギー統合 – Ensuring renewable energy sources work seamlessly with existing grids necessitates advanced testing solutions.
規制遵守 – Stringent international standards for reliability, safety, and efficiency make comprehensive power system validation essential.
Maximized Reliability – Prevent unexpected power failures with accurate load simulation that ensures systems perform under peak demand.
コスト効率 – Early detection of potential issues minimizes maintenance costs and extends the lifespan of expensive power equipment.
Compliance Confidence – Meets global standards and safety regulations, giving organizations peace of mind.
Operator-Friendly Design – The intuitive interface reduces the complexity of testing, making it accessible even to operators with minimal technical experience.
Energy & Utilities – Validate power generation and distribution systems for maximum uptime.
通信 – Guarantee uninterrupted network operations through rigorous backup system testing.
Healthcare – Maintain critical medical equipment and emergency power systems without disruption.
Defense & Military – Verify the readiness and reliability of mission-critical power infrastructure.
「 TheGROAD 1068 AC Load Bank is more than just a testing device—it is a strategic investment in reliability, efficiency, and safety. Combining advanced digital controls, high load capacity, and durable construction, it empowers industries to anticipate potential issues, optimize performance, and ensure operational continuity.
With the GROAD 1068, your power systems are tested not just for today, but for the future, delivering unmatched confidence in energy reliability.