GROADA-AC380V-150KW-RL抵抗負荷バンク
The GROADA-AC380V-150KW-RL resistive load bank is a high-performance testing device designed to simu...
| モデル | AC220V-10KVA-RL | AC380 型V-30KVA-RL | AC380 型V-60KVA-RL | AC380 型V-100KVA-RL | AC380 型V-300KVA-RL | AC380 型V-500KVA-RL | AC380 型V-1000KVA-RL |
| 評価パワー | RL=10KVA | RL=30KVA | RL=60KVA | RL=100KVA | RL=300KVA | RL=500KVA | RL=1000KVA |
| R=10KW;L=6KVA | R=30KW;L=18KVA | R=60KW;L=36KVA | R=100KW;L=60KVA | R=300KW;L=180KVA | R=500KW;L=300KVA | R=1000KW;L=600KVA | |
| 入力電流 | 0〜45A | 0〜45A | 0-90A | 0〜150A | 0-450A | 0-750A | 0-1500A |
| サイズ(幅*深さ*高さmm) | 480*600*277 | 480*600*360 | 500*750*1000 | 600*850*1000 | 700*1000*1650 | 1100*1400*1700 | 1100*1500*1900 |
| 重量 | 25キログラム | 40キログラム | 80キログラム | 130キログラム | 250キログラム | 550キログラム | 750キログラム |
| 最小負荷 | 100W | 100W | 100W | 500W | 1KW | 5KW | 10KW |
| 他の最低負荷力は条件に従ってカスタマイズすることができます | |||||||
| 入力電圧 | AC220/230V | AC380/400V | |||||
| 他の入力電圧は条件に従ってカスタマイズできます | |||||||
| パワーファクター | PF = 0.8/1.0(他のパワー要因は条件に応じてカスタマイズすることができます) | ||||||
| 全体的な精度 | 3%(他の正確さの条件は条件に従ってカスタマイズすることができます) | ||||||
| 制御モード | ローカルマニュアル/リモートホストコンピュータ(ローカルマニュアル制御モード:ブレーカー/ボタン/タッチスクリーン三向任意、他の方法は必要に応じてカスタマイズすることができます) | ||||||
| リモートインターフェース | RS232/RS485/USB/RJ45/CAN/GPIB(他のインターフェースモードは条件に応じてカスタマイズすることができます) | ||||||
| 保護機能 | 緊急停止保護,過熱保護,ファン負荷インターロック保護,接地保護 (過電圧保護,過電流保護,短回路保護,ファン過負荷,空気量不足を選択) | ||||||
| 働く電源 | AC220V の | AC220V/380V | AC380V の | ||||
| 表示精度 | 0.5レベル(他の明確な精度は条件に従ってカスタマイズすることができます) | ||||||
| 表示パラメータ | 電圧、電流、力、周波数、パワー要因等 (他の明示的な方法は条件に従ってカスタマイズすることができます) | ||||||
| 冷たい確かな方法 | 側面の空気入口および上の空気出口(他の空気出口方法は条件に応じてカスタマイズすることができます) | ||||||
| 保護レベル | IP20(他の保護レベルは条件に従ってカスタマイズすることができます) | ||||||
| 外観色 | RAL7035(他の色は条件に従ってカスタマイズすることができます) | ||||||
| 作業温度 | -10 ℃ ~ 55 ℃ | ||||||
| 相対湿度 | ≤95%RH | ||||||
| 高さ | ≤ 2500 m | ||||||
ミッションクリティカルな電力システムの投入、メンテナンス、または検証では、「単なる負荷」以上が必要です。実際の条件下で精度、柔軟性、自信が必要です。 「 TheGROADA AC600V 180 kVA RL 抵抗感導負荷銀行フルスペクトルの発電機/UPS/電源システムのテストのための堅固でフィールド証明されたプラットフォームを提供します。抵抗力と誘導負荷要素を1つのコンパクトでモジュール化されたソリューションに組み合わせています。
実際の (抵抗的) および反応的 (誘導的) 負荷の両方をシミュレーションすることで (通常 0.8 のようなターゲットパワーファクターで), この RL 負荷バンクは,システム電圧の安定性,電流応答,一時的な行動,および発電機の完全なネームプレート機能を実際の展開前に検証するのに役立ちます.
抵抗負荷(実際の電力)と誘導負荷(遅れた反応電力)をサポートし、より現実的な電力システムストレステストを可能にします。
テストを提供できます0.8パワーファクター電阻および感導セクションを組み合わせることで、発電機受け入れ試験のための一般的に受け入れられている標準です。
柔軟な操作を提供します:抵抗のみモード,誘導のみモード,または必要に応じて組み合わせたRLモード.
評価600V AC入力、三相 (要求に応じて利用可能な他の電圧)。
評価された容量:180キロボルトアンペア通常 ~144 kW 抵抗 + ~108 kVAR 誘導(構成に応じて)を意味します。
ロード ステップ as fine as100 W / 100 VAR (またはより高い粒度のオプション)、正確な負荷調節を可能にします。
精度: ±3%(要求に応じてより厳格な許容にカスタマイズ可能)。
ディスプレイ&モニタリング: 電圧、電流、実際および反応電力、周波数、電力因子、等を示します。
制御オプション:ローカルマニュアル(ブレーカー、ボタン、タッチパネル)またはリモートインターフェイス(RS232 / RS485 / USB / RJ45 / CAN / GPIB) - テストリグまたはSCADAシステムに統合することができます。
緊急停止(E-停止)保護により、重大な条件下で即座に負荷を取り除くことができます。
過熱,ファン故障,過電流,短路,および不十分な空気流れ保護.
安全な操作を保証するための地面保護および隔離。
IP rating (e.g. IP20 standard) (optional upgrades for harsher environments).
Thermal management: side air intake / top exhaust, modular airflow design to reduce hotspots.
Designed to operate over –10 °C to +55 °C ambient, up to ~2,500 m altitude.
Enclosure constructed from heavy-gauge steel, powder-coated for corrosion resistance.
Modular sections for resistive and inductive elements; scalable and maintainable.
Forklift channels or lifting eyes provided for ease of installation.
Compact footprint given the power class, enabling rooftop, pad, or indoor installation.
Customization: different frame sizes, color (RAL family), door arrangements, cooling layouts.
Generator Commissioning & Load Acceptance Tests
Validate that your generator set can sustain rated kVA, voltage regulation, transient response, and reactive load behavior before it enters service.
UPS / Power System Integration Testing
Emulate real-world loads (including reactive loads such as motors and inductive circuits) to ensure the UPS and switchgear respond correctly under full stress.
Parallel Generator Synchronization & Load Sharing
Use the RL load bank to balance and test load sharing across multiple gensets, ensuring stability during parallel operations.
Routine Preventive Maintenance / Health Checks
Regular load banking helps avoid “wet stacking” (in diesel gensets running light) and can burn off carbon buildup, improving fuel efficiency and engine life.
Many industry guidelines recommend at least annual full-load testing under rated power factor.
Design Validation & R&D in Power Systems
For OEMs, labs, or integrators, the RL load bank is essential when developing alternators, power converters, controllers, or new power architectures (e.g. microgrids).
Data Centers, Telecom, Critical Infrastructure
In critical facilities where downtime is not tolerated, you must ensure every component performs under combined resistive and reactive stress.
Expertise & Authority: GROADA has decades of experience in power testing equipment, certified by relevant quality and safety standards.
Certifications & Quality Control: Each RL unit undergoes factory calibration, burn-in, and full functional testing before delivery.
Transparent Specifications: All electrical, thermal, mechanical parameters are documented and open to customer review or 3rd-party validation.
Post-Sales Support & Warranty: GROADA offers technical support, spare parts, and extended warranties — helping clients confidently deploy and maintain systems.
Integrated dual-mode design eliminates the need to buy separate resistive and inductive banks — saving cost, footprint, and complexity.
Fine load step resolution and remote control capability give customers flexibility for nuanced stress tests.
Strong reliability and proven design reduce lifetime maintenance and downtime risk.
Customs and configurations possible: if your project needs a custom voltage, power factor, enclosure, or interface, GROADA can accommodate.