GROADA-AC380V-150KW-RL抵抗負荷バンク
The GROADA-AC380V-150KW-RL resistive load bank is a high-performance testing device designed to simu...
| モデル | AC220V-10KVA-RL | AC380 型V-30KVA-RL | AC380 型V-60KVA-RL | AC380 型V-100KVA-RL | AC380 型V-300KVA-RL | AC380 型V-500KVA-RL | AC380 型V-1000KVA-RL |
| 評価パワー | RL=10KVA | RL=30KVA | RL=60KVA | RL=100KVA | RL=300KVA | RL=500KVA | RL=1000KVA |
| R=10KW;L=6KVA | R=30KW;L=18KVA | R=60KW;L=36KVA | R=100KW;L=60KVA | R=300KW;L=180KVA | R=500KW;L=300KVA | R=1000KW;L=600KVA | |
| 入力電流 | 0〜45A | 0〜45A | 0-90A | 0〜150A | 0-450A | 0-750A | 0-1500A |
| サイズ(幅*深さ*高さmm) | 480*600*277 | 480*600*360 | 500*750*1000 | 600*850*1000 | 700*1000*1650 | 1100*1400*1700 | 1100*1500*1900 |
| 重量 | 25キログラム | 40キログラム | 80キログラム | 130キログラム | 250キログラム | 550キログラム | 750キログラム |
| 最小負荷 | 100W | 100W | 100W | 500W | 1KW | 5KW | 10KW |
| 他の最低負荷力は条件に従ってカスタマイズすることができます | |||||||
| 入力電圧 | AC220/230V | AC380/400V | |||||
| 他の入力電圧は条件に従ってカスタマイズできます | |||||||
| パワーファクター | PF = 0.8/1.0(他のパワー要因は条件に応じてカスタマイズすることができます) | ||||||
| 全体的な精度 | 3%(他の正確さの条件は条件に従ってカスタマイズすることができます) | ||||||
| 制御モード | ローカルマニュアル/リモートホストコンピュータ(ローカルマニュアル制御モード:ブレーカー/ボタン/タッチスクリーン三向任意、他の方法は必要に応じてカスタマイズすることができます) | ||||||
| リモートインターフェース | RS232/RS485/USB/RJ45/CAN/GPIB(他のインターフェースモードは条件に応じてカスタマイズすることができます) | ||||||
| 保護機能 | 緊急停止保護,過熱保護,ファン負荷インターロック保護,接地保護 (過電圧保護,過電流保護,短回路保護,ファン過負荷,空気量不足を選択) | ||||||
| 働く電源 | AC220V の | AC220V/380V | AC380V の | ||||
| 表示精度 | 0.5レベル(他の明確な精度は条件に従ってカスタマイズすることができます) | ||||||
| 表示パラメータ | 電圧、電流、力、周波数、パワー要因等 (他の明示的な方法は条件に従ってカスタマイズすることができます) | ||||||
| 冷たい確かな方法 | 側面の空気入口および上の空気出口(他の空気出口方法は条件に応じてカスタマイズすることができます) | ||||||
| 保護レベル | IP20(他の保護レベルは条件に従ってカスタマイズすることができます) | ||||||
| 外観色 | RAL7035(他の色は条件に従ってカスタマイズすることができます) | ||||||
| 作業温度 | -10 ℃ ~ 55 ℃ | ||||||
| 相対湿度 | ≤95%RH | ||||||
| 高さ | ≤ 2500 m | ||||||
信頼性 | コンパクト | 技術的に精密
「 TheGROADA RL シリーズ 6 kW 抵抗感導負荷バンク正確な負荷シミュレーションのために設計された専門のACテストソリューションです0.8パワーファクターそれは正確な、繰り返し可能な性能テストを提供します発電機,UPSシステム,インバーター,変圧器,および電源制御装置高品質の抵抗および誘導要素で構築されたこのユニットは、反応的な条件の下で真の力の行動を確認するために現実世界の混合負荷を複製します。
抵抗のみの負荷バンクとは異なり、GROADA RLモデルは抵抗(R)と誘導(L)回路の両方を統合し、lagging power factor of 0.8. This enables realistic testing of equipment where reactive current is critical—such as motor-driven systems, industrial drives, or power distribution networks.
Benefits:
Accurately assess generator voltage regulation and frequency response
Validate UPS and inverter performance under inductive loading
Ensure system stability under real-world operating conditions
The RL 6 kW load bank offers finely tuned load increments (as low as 0.1 kW / 0.1 kVAR) for smooth ramping and precise test profiling.
Operators can easily simulate step-load changes, transient conditions, or progressive loading to observe system reactions without overshoot or instability.
Built to GROADA’s high manufacturing standards, this model is suitable for both indoor and outdoor操作。
Construction Highlights:
Heavy-duty, powder-coated steel enclosure
Corrosion-resistant finish and reinforced frame
Independent compartments for resistive and inductive sections
Forced-air cooling with airflow monitoring
Optional anti-condensation heater for cold / humid environments
Safety and reliability are embedded into every GROADA design.
Protection Functions Include:
Over-temperature and over-current protection
Airflow failure detection with automatic shutdown
Phase imbalance protection
Emergency stop (E-Stop) switch
Real-time fault indicators and audible alarms
These safeguards ensure continuous protection of both equipment and personnel during testing.
The 6 kW RL Load Bank can operate as a stand-alone unit or be paralleled with other GROADA load banks for higher-capacity applications.
Its modular design is ideal for:
Laboratory testing environments
Service / rental fleet configurations
On-site commissioning projects
Integrated metering supports real-time monitoring of:
Voltage, Current, Power (kW), Reactive Power (kVAR), Power Factor, Frequency, and Energy.
Data can be logged for quality assurance, trend analysis, and compliance documentation—supporting consistent performance verification across test cycles.
| パラメータ | Value / Range |
|---|---|
| 評価された力 | 6 kW (Resistive + Inductive) |
| パワーファクター | 0.8 (lagging) |
| 電圧評価 | AC 400 V ±10% / 50 or 60 Hz |
| 負荷解像度 | 0.1 kW / 0.1 kVAR steps |
| Cooling | Forced-air cooling, top discharge |
| 保護 | Over-temperature, over-current, airflow failure, E-stop |
| Enclosure Type | Industrial-grade steel, IP rated, powder-coated |
| Operation | Indoor / Outdoor (floor mounted with optional lifting slots) |
| 測定 | Digital display / optional remote monitoring interface |
Specifications subject to customization. GROADA provides bespoke load configurations to meet special testing requirements.
Generator Commissioning & Maintenance – Simulate true power factor loading during factory or field acceptance tests.
UPS & Inverter Testing – Verify inverter stability, switching accuracy, and heat dissipation under reactive load.
Motor & Drive System Validation – Recreate inductive load conditions typical of industrial motors, pumps, and fans.
Power R&D Laboratories – Perform advanced AC performance analysis, transient simulation, and component evaluation.
Rental / Service Fleets – Combine modular units for higher capacity and portable deployment in field projects.
With extensive experience in load bank manufacturingそしてpower testing solutions, GROADA delivers high-performance, durable, and globally certified equipment trusted by professionals in power generation, energy storage, marine, and industrial sectors.
All GROADA load banks undergo full Factory Acceptance Tests (FAT) and conform to international standards such as IEC and GB guidelines for electrical safety, performance, and reliability.
We provide:
Detailed technical documentation and schematics
Operation & maintenance manuals
On-site commissioning and training support
After-sales service and spare parts availability
To strengthen online visibility and authority:
Use focus keywords: “resistive-inductive load bank”, “0.8 power factor load bank”, “AC 400V load bank 6 kW”, “generator load testing equipment”
Add secondary phrases: R-L load bank, reactive load testing, portable load bank for UPS
Ensure all images have descriptive ALT text and optimized filenames
Add product schema markup (JSON-LD) for structured data (model, specs, brand, etc.)
Encourage customer reviews or project case studies to reinforce trust signals
Update content periodically with technical articles or application notes related to load testing
「 TheGROADA RL 6 kW Resistive-Inductive Load Bank is an efficient and reliable solution for accurate load simulation, ensuring that your power systems perform safely and consistently under real operating conditions.
With GROADA’s engineering expertise, safety-driven design, and international service support, you can rely on lasting precision and peace of mind in every test.