GROADA-AC600V-25KW-RCD逆变器负载组
The GROADA AC600V-25kW RCD Load Bank is a professional testing device designed to simulate real-worl...
| 模型 | AC220V-5KW-RCD | AC220V-10KW-RCD | AC220V-15KW-RCD | AC220V-20KW-RCD | AC380V-30KW-RCD | AC380V-50KW-RCD | AC380V-60KW-RCD | AC380V-100KW-RCD | AC380V-200KW-RCD |
| 额定功率 | R=5KW | R=10KW | R=15KW | R=20KW | R=30KW | R=50KW | R=60KW | R=100KW | R=200KW |
| RCD=5KVA | RCD=10KVA | RCD=15KVA | RCD=20KVA | RCD=30KVA | RCD=50KVA | RCD=60KVA | RCD=100KVA | RCD=200KVA | |
| 输入电流 | 0-22A | 0-45A | 0-45A | 0-90A | 0-45A | 0-3:00 | 0-450A | 0-600A | 0-750A |
| 尺寸(宽*深*高mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| 重量 | 50KG | 80公斤 | 100公斤 | 130公斤 | 200KG | 300公斤 | 350公斤 | 450公斤 | 550公斤 |
| 输入电压 | 交流220/230V | 交流380/400V | |||||||
| 其他输入电压可根据要求定制 | |||||||||
| 最小载荷 | 100W | 100W | 100W | 100W | 100W | 1千瓦 | 1千瓦 | 1千瓦 | 1千瓦 |
| 其他最小负载功率可根据要求定制 | |||||||||
| 整体精度 | 3%(其他精度要求可根据要求定制) | ||||||||
| 功率因数 | PF=0.6~1.0 | ||||||||
| 峰形系数 | 2至3 | ||||||||
| 控制模式 | 本地手动/远程主机(本地手动控制模式:断路器/按钮/触摸屏三路可选,其他方法可根据需要定制) | ||||||||
| 远程接口 | RS232/RS485/USB/RJ45/CAN/GPIB(其他接口模式可根据要求定制) | ||||||||
| 保护功能 | 紧急停机保护、超温保护、风机负载联锁保护、接地保护(选择过压保护、过流保护、短路保护、风机超负荷、风量不足) | ||||||||
| 工作电源 | AC220V | AC220V/AC380V | |||||||
| 显示精度 | 0.5级(其他显式精度可根据要求定制) | ||||||||
| 显示参数 | 电压、电流、功率、频率、功率因数等。(其他显式方法可根据要求定制) | ||||||||
| 冷肯定的方式 | 侧进风口和上出风口(其他出风口方式可根据要求定制) | ||||||||
| 保护级别 | IP20(其他防护等级可根据要求定制) | ||||||||
| 外观颜色 | RAL7035(其他颜色可根据要求定制) | ||||||||
| 工作温度 | -10 ℃ ~ 55 ℃ | ||||||||
| 相对湿度 | ≤95%相对湿度 | ||||||||
| 高度 | ≤2500米 | ||||||||
这GROADA AC600V-25kW RCD Load Bank is a professional testing device designed to simulate real-world electrical loads for generators, UPS systems, power inverters, and other electrical equipment. By accurately replicating resistive, inductive, and capacitive loads, it enables engineers to verify system performance, stability, and safety under various operating conditions.
Key Features:
High Voltage Compatibility – Supports up to AC 600V for medium- and high-voltage testing.
25kW Adjustable Load – Flexible load steps to simulate multiple scenarios.
RCD Safety Protection – Built-in Residual Current Device ensures operator and equipment safety.
Modular & Scalable – Easily expandable for higher capacity applications.
User-Friendly Control – Digital interface with local and remote monitoring options.
| Item | 规格说明 |
|---|---|
| 模型 | AC600V-25kW RCD |
| 额定电压 | 0–600V AC |
| 额定功率 | 25kW |
| 负载类型 | Resistive / Inductive / Capacitive |
| 控制选项 | Digital / Manual / Remote interface |
| Accuracy | ±0.5% |
| 冷却方法 | Forced air cooling (optional water cooling) |
| Safety Protection | Overload, short-circuit, grounding, RCD protection |
| Dimensions / Weight | (Customize according to actual model) |
Load banks have become an essential tool in power reliability testing, especially for data centers, power plants, and mission-critical facilities.
这global load bank market was valued at USD 288.17 million in 2024 and is projected to grow at a CAGR of 3.7% through 2032.
Another report estimates the market will reach USD 303.2 million by 2025 and USD 412.9 million by 2032 (CAGR ~4.5%).
North America accounted for over USD 106 million in 2024, maintaining steady growth.
Emerging trends include modular design, automated testing, hybrid load simulation (resistive + inductive), and remote monitoring solutions.
With years of expertise, GROADA integrates these cutting-edge technologies into our products, ensuring reliable, efficient, and safe load testing solutions for global customers.
Generator set performance testing and commissioning
UPS and battery system capacity verification
Inverter and VFD (Variable Frequency Drive) load response testing
Power equipment troubleshooting and preventive maintenance
Data center and critical power system validation
Power Plant Commissioning – A major utility company used the AC600V-25kW load bank to validate standby generator systems under 90% load, ensuring stable power delivery.
Data Center Validation – A Tier-III data center successfully simulated peak load conditions to test UPS redundancy and battery response.
Industrial Project – During factory acceptance testing, our load bank enabled engineers to simulate real operating conditions, reducing post-installation faults.
Operation Steps:
Verify system voltage compatibility.
Connect grounding and safety wiring.
Interface with local or remote control system.
Gradually apply load steps and monitor parameters.
Safety Precautions:
Do not exceed rated load and voltage range.
Always ensure proper grounding.
Only qualified personnel should operate.
Inspect wiring, fans, and resistors regularly.
Maintenance Recommendations:
Keep ventilation unobstructed.
Clean dust and debris periodically.
Perform annual calibration to maintain accuracy.
Avoid continuous operation at full load for extended periods.
Q1: What is an AC load bank?
A: An AC load bank simulates electrical loads to test power sources such as generators and UPS systems, ensuring they can perform reliably under real operating conditions.
Q2: Why is RCD protection important?
A: The built-in Residual Current Device (RCD) disconnects the circuit in case of leakage current, providing essential safety in high-voltage environments.
Q3: Is 25kW suitable for my application?
A: If your system requires up to 25kW testing at 600V, this model is ideal. For higher power requirements, multiple units can be connected in parallel.
Q4: What is the accuracy of this load bank?
A: It delivers precision testing with a load accuracy of ±0.5%, ensuring reliable measurement results.
Q5: Can I request a customized model?
A: Yes, GROADA offers customized high-power, modular, or multi-channel load banks tailored to specific project needs.
Built under ISO 9001 certified quality management system
CE / IEC / UL compliance available (model dependent)
Calibration and third-party test reports provided on request
Standard 12-month warranty with extended service options
Lifetime technical support and fast response service
Over 10 years of engineering experience in load bank manufacturing
Trusted by customers in power generation, aerospace, data centers, and renewable energy sectors
Proven track record with successful projects worldwide
Dedicated R&D team providing cutting-edge testing solutions