负载箱

GROADA-AC120V-50KVA-RCD逆变器负载组

★★★★★
主要产品:
  • 交流负载组:R/RL/RLC/RCD
  • 直流负载组:DC5V-2000V,0A-5000A


模型AC220V-5KW-RCDAC220V-10KW-RCDAC220V-15KW-RCDAC220V-20KW-RCD交流380v-30千瓦/日交流380v-50KW-RCD交流380v-60KW-RCD交流380v-100KW-RCD交流380v-200KW-RCD
额定功率R=5KWR=10KWR=15KWR=20KWR=30KWR=50KWR=60KWR=100KWR=200KW
RCD=5KVARCD=10KVARCD=15KVARCD=20KVARCD=30KVARCD=50KVARCD=60KVARCD=100KVARCD=200KVA
输入电流0-22A0-45A0-45A0-90A0-45A0-3:000-450A0-600A0-750A
尺寸(宽*深*高mm)500*600*800500*600*1000500*600*1100500*750*1100600*850*1400600*850*1600600*850*1850700*1000*18001100*1400*1800
重量50KG80公斤100公斤130公斤200KG300公斤350公斤450公斤550公斤
输入电压交流220/230V交流380/400V
其他输入电压可根据要求定制
最小载荷100W100W100W100W100W1千瓦1千瓦1千瓦1千瓦
其他最小负载功率可根据要求定制
整体精度3%(其他精度要求可根据要求定制)
功率因数PF=0.6~1.0
峰形系数2至3
控制模式本地手动/远程主机(本地手动控制模式:断路器/按钮/触摸屏三路可选,其他方法可根据需要定制)
远程接口RS232/RS485/USB/RJ45/CAN/GPIB(其他接口模式可根据要求定制)
保护功能紧急停机保护、超温保护、风机负载联锁保护、接地保护(选择过压保护、过流保护、短路保护、风机超负荷、风量不足)
工作电源AC220VAC220V/AC380V
显示精度0.5级(其他显式精度可根据要求定制)
显示参数电压、电流、功率、频率、功率因数等。(其他显式方法可根据要求定制)
冷肯定的方式侧进风口和上出风口(其他出风口方式可根据要求定制)
保护级别IP20(其他防护等级可根据要求定制)
外观颜色RAL7035(其他颜色可根据要求定制)
工作温度-10 ℃ ~ 55 ℃
相对湿度≤95%相对湿度
高度≤2500米


1.引言——为什么为关键电力系统选择逆变器负载组

在现代电力基础设施中,在实际负载条件下测试和验证电源行为的精度至关重要。这AC 120V 50 kVA RCD逆变器负载组GROADA的设计用于在安全和可重复的条件下模拟逆变器、UPS、发电机和电池系统的真实电气负载。

使用电阻性、无功性或组合负载模拟,逆变器负载组有助于在潜在的性能或稳定性问题影响运行之前发现这些问题。该设备在以下方面特别有价值:

  • 调试新的电力系统或逆变器

  • 储能系统的日常维护

  • 备用发电机和UPS的压力测试

  • 确保系统符合安全和监管标准


2.产品概述和;主要特点

以下是访问者关心的功能的高级细分,这将有助于搜索引擎了解页面的相关性和深度:

  • 额定输出:120伏交流电,50千伏安

  • RCD保护和;安全:包括保护操作员和设备的剩余电流装置

  • 逆变器兼容操作:支持双向或受控负载注入,以模拟逆变器行为

  • 精确的负载控制:多步或连续控制,具有精确的电流/电压计量

  • 冷却和;热管理:采用智能风扇控制的强制风冷来管理电阻元件的温度

  • 监测和;通信:本地显示器和可选的远程接口(例如通过RS-485、以太网或其他协议)

  • 模块化和;可维护设计:可更换的电阻器模块,易于接近的面板

  • 保护和;安全特性:过电流、超温、短路、紧急停止

通过强调这些方面,该页面向用户和谷歌发出信号,表明它包含有用、详细的产品内容,而不是肤浅的营销废话。


3.技术背景和;行业背景

为了建立信任和权威,将此产品置于更广泛的技术和市场背景中是有用的:

什么是负载银行?
负载组是一种以受控方式在电源上施加电负载的设备,将能量(通常通过电阻器)转化为热量,通常通过强制空气或水冷系统消散。这使工程师能够在已知的稳定负载下测试发电机、UPS、逆变器或电池,而不依赖于不可预测的实际负载行为。

为什么逆变器兼容负载组?
传统的电阻性负载组施加静态负载;然而,逆变器负载组可以更接近地模拟动态功率转换行为(例如电压降、谐波响应),并且可以与电力电子设备结合使用。这在现代微电网、可再生能源系统和储能测试台上尤其重要。

市场趋势和;需求

  • 从2025年到2032年,全球负荷银行市场预计将以约3.7%的复合年增长率(CAGR)增长,从2025年的约3亿美元扩大到2032年底的约3.87亿美元

  • 驱动因素包括数据中心部署的增加、可再生能源的整合、更严格的电力可靠性标准以及电池/逆变器系统的更广泛使用。能量+1

  • 在亚太地区,特别是中国和印度,工业扩张和电力基础设施升级正在加速对负载测试和调试设备的需求。 

通过引用这些数据点(附有引文),该页面表明该产品在一个不断增长的技术驱动型行业中具有相关性。


4. Applications & Use Cases

To further increase relevance and user trust, lay out concrete scenarios where your product adds value:

ApplicationBenefit / Use Case
Generator commissioning & acceptance testingVerify full-load performance, thermal stability, load transient response
UPS & battery system verificationConfirm DC–AC inverter behavior under load, simulate real consumption profiles
Renewable + storage systemsDuring debugging/integration, impose known loads on inverter systems to test control logic
Maintenance & preventive testingRoutinely exercise systems to avoid “wet stacking,” carbon build-up, or capacity derating
Data center & mission critical facilitiesValidate that backup systems can seamlessly take over under full load

Including real user scenarios helps Google and users see your page as practically useful, boosting engagement and dwell time (factors that support SEO).


5. Technical Considerations & Best Practices

To help engineers / purchasers make informed decisions, you can include guidance or best practices:

  • Sizing margin: Choose a load bank with at least 20% headroom above expected maximum load to ensure longevity and safety under transient stress.

  • Power factor and reactance: If users need to test non-unity power factor loads (e.g. inductive or capacitive), consider combining with reactive modules or using R / L / C combination load banks. 

  • Cooling & ambient conditions: The design must account for ambient temperature, ventilation constraints, and altitude.

  • Measurement accuracy: Use high-precision voltage and current sensors, with calibration, to ensure valid test data.

  • Safety and compliance: Design must comply with relevant electrical safety standards (e.g. IEC, UL, local codes), use proper insulation, earthing, overcurrent protection, and safe operator interface.

  • Maintenance tips: Periodic inspection of resistor elements, fan filters, connection integrity, insulation resistance, and firmware upgrades (if remote control is supported).

By offering this level of detail, the page becomes more than a sales pitch — it’s a resource, strengthening EEAT.


6. Why Trust GROADA — Company Credibility

To boost trust (the “T” in EEAT), you should include or anchor (in surrounding parts of the site) elements like:

  • Company credentials & history: e.g. years of experience in power test / electrical load equipment manufacturing

  • Certifications & standards compliance: ISO, CE, UL, or others

  • Case studies / project references: real projects where this unit or similar ones were deployed (data centers, utility projects, etc.)

  • Third-party validation / testimonials: quotes from users, labs, or certifications

  • After-sales support & warranty: spare parts, calibration service, technical support coverage

In the body you can include a brief paragraph like:

GROADA is a specialist in power test solutions, with X years of experience designing reliable load banks. All units are factory tested, and we provide global after-sales support, spare parts, and calibration service to assure your long-term operational reliability.


7. Call to Action (without hard linking)

Conclude with a user-focused, persuasive call to action, e.g.:

For detailed specifications, drawings, or customized configurations of the 120 V 50 kVA RCD inverter load bank, please contact our technical team. Let us help tailor a load testing solution that fits your system needs — from initial sizing to full test commissioning and long-term support.

我们的产品