GROADA-AC346V-50KVA-RL резистивный индуктивный нагрузочный банк
GROADA AC346V-50KVA RL AC Load Bank is a high-precision resistive-inductive (RL) load cabinet design...
| Модель | AC220V-10KVA-РЛК | AC380V-30KVA-РЛК | AC380V-60KVA-РЛК | AC380V-100KVA-РЛК | AC380V-200KVA-РЛК | AC380V-300KVA-РЛК |
| Номинальная мощность | РЛК = 10 КВА | РЛК = 30КВА | РЛК=60КВА | РЛК=100КВА | РЛК=200КВА | RLC = 300 КВА |
| R = 10 кВт; L = 10 КВА С = 10КВА | R = 30 кВт; L=30КВА; С=30КВА | R = 60 кВт; L = 60 КВА; С=60КВА | R = 100 кВт; L = 100 КВА; С=100КВА | R = 200 кВт; L = 200 КВА; С=200КВА | R = 300 кВт; L = 300 КВА; С=300КВА | |
| Другая мощность может быть настроена в соответствии с требованиями | ||||||
| Размер (ширина * глубина * высота мм) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| Вес | 120 кг | 380кг | 580кг | 880 кг | 1500 кг | 2500кг |
| Входное напряжение | AC220/230В | AC380/400В | ||||
| Другое входное напряжение может быть настроено в соответствии с требованиями | ||||||
| Входный ток | 0-45А | 0-45А | 0-90А | 0-150А | 0-300А | 0-450А |
| Минимальная нагрузка | R = 100 Вт; L=100VA; С=100ВА | R = 100 Вт; L=100VA; С=100ВА | R = 100 Вт; L=100VA; С=100ВА | R = 100 Вт; L=100VA; С=100ВА | R = 1 кВт; L = 1 КВА; С=1КВА | R = 1 кВт; L = 1 КВА; С=1КВА |
| Другая минимальная мощность загрузки может быть настроена в соответствии с требованиями | ||||||
| коэффициент мощности | PF = 0,1 ~ 1,0 (другой коэффициент мощности может быть настроен в соответствии с требованиями) | |||||
| Общая точность | 3% (другие требования точности могут быть настроены в соответствии с требованиями) | |||||
| Режим управления | Локальный ручный/удаленный хост-компьютер (локальный режим ручного управления: выключатель/кнопка/сенсорный экран трехсторонний опциональный, другие методы могут быть настроены по мере необходимости) | |||||
| Удаленный интерфейс | RS232/RS485/USB/RJ45/CAN/GPIB (другие режимы интерфейса могут быть настроены в соответствии с требованиями) | |||||
| Функция защиты | Защита от аварийной остановки, защита от перетемпературы, защита от блокировки нагрузки вентилятора, защита от заземления (выберите защиту от перенапряжения, защиту от перетока, защиту от короткого замыкания, перегрузку вентилятора, недостаточный объем воздуха) | |||||
| Рабочее питание | АЦ220В | AC220V / 380V | АЦ380В | |||
| Точность отображения | Уровень 0,5 (другая явная точность может быть настроена в соответствии с требованиями) | |||||
| Параметры отображения | Напряжение, ток, мощность, частота, коэффициент мощности и т.д. (другие явные методы могут быть настроены в соответствии с требованиями) | |||||
| Холодный уверенный способ | Бочный вход воздуха и верхний выход воздуха (другие методы выхода воздуха могут быть настроены в соответствии с требованиями) | |||||
| Уровень защиты | IP20 (другой уровень защиты может быть настроен в соответствии с требованиями) | |||||
| Внешний цвет | RAL7035 (другие цвета могут быть настроены в соответствии с требованиями) | |||||
| Рабочая температура | -10 ℃ ~ 55 ℃ | |||||
| Относительная влажность | ≤95%RH | |||||
| Высота | ≤ 2500 м | |||||
ВGROADA AC800V-851kW RLC Load Bank is a state-of-the-art solution designed to deliver accurate, reliable, and safe testing for high-capacity AC power systems. Engineered with cutting-edge RLC (Resistive, Inductive, Capacitive) technology, this load bank replicates real-world electrical conditions, enabling thorough validation of generators, UPS systems, and industrial power infrastructure.
With a substantial power rating of 851kW at 800V AC, it is ideal for large-scale installations, ensuring that every component of your power network performs optimally under full-load conditions. The GROADA AC800V series combines precision engineering, advanced control systems, and robust safety protocols, making it a trusted choice for engineers and facility managers worldwide.
Поддержкаup to 851kW at 800V AC, accommodating demanding power systems with ease.
Enables full-load testing of generators, UPS units, and industrial power grids.
Integrates resistive, inductive, and capacitive loads to simulate a variety of electrical conditions.
Accurately replicates both balanced and unbalanced loads for realistic system testing.
Modular architecture allows for customized load configurations, adaptable to evolving testing requirements.
Facilitates transport and installation in diverse operational environments.
User-friendly interface with real-time monitoring of voltage, current, power factor, and temperature.
Provides precise load adjustments to ensure reliable and repeatable testing results.
Equipped with over-temperature protection, short-circuit safeguards, and emergency shutdown functions.
Designed to maintain operational safety in both laboratory and field environments.
The AC800V-851kW RLC Load Bank is engineered for versatility, providing essential support for multiple sectors:
Power Generation Facilities: Validate generator performance under full-load and transient conditions to prevent operational failures.
Центры обработки данных: Test UPS systems, emergency generators, and critical power circuits to ensure uninterrupted service.
Renewable Energy Systems: Simulate grid conditions for solar, wind, and hybrid energy installations to optimize integration and performance.
Industrial Manufacturing: Verify electrical distribution systems, motors, and heavy equipment for safety and efficiency.
Research and Development: Support engineers in designing and testing new power solutions with accurate load simulation.
The global load bank market is witnessing substantial growth due to rising demand for reliable and resilient power infrastructure. Key trends shaping this growth include:
Expansion of Data Centers: The surge in cloud computing and digital services necessitates robust backup power testing.
Renewable Energy Integration: Solar and wind systems require precise load management for grid stability.
Technological Advancements: Modern load banks now feature modularity, digital monitoring, and energy-efficient designs.
These trends highlight the critical role of advanced load banks like the GROADA AC800V-851kW in ensuring operational reliability and efficiency.
Proven Expertise: Years of industry experience delivering high-performance power testing solutions.
Tailored Solutions: Modular designs customized to meet specific testing needs and capacities.
Global Service Network: Worldwide support ensures installation, maintenance, and technical guidance wherever needed.
Uncompromising Quality: Rigorous quality control ensures durability, safety, and long-term reliability.
Innovation Leadership: Commitment to continuous product development and adoption of advanced technologies.
| Особенность | Спецификация |
|---|---|
| Номинальное напряжение | 800V AC |
| Maximum Power | 851kW |
| Тип нагрузки | RLC (Resistive, Inductive, Capacitive) |
| Control System | Digital panel with real-time monitoring |
| Особенности безопасности | Over-temperature, short-circuit protection, emergency shutdown |
| Design | Modular and scalable for flexible deployment |
ВGROADA AC800V-851kW RLC Load Bank is more than just a testing tool—it is a strategic asset for ensuring the reliability, safety, and efficiency of critical AC power systems. Whether for power plants, data centers, industrial facilities, or renewable energy installations, it delivers precision, adaptability, and peace of mind.
Invest in GROADA load banks to guarantee performance under load, validate your systems with confidence, and safeguard your power infrastructure for years to come.