Банк нагрузки инвертора GROADA-AC380V-50KW-R/RCD
The GROADA AC380V-50KW-R/RCD inverter test load bank is a high-performance testing device specifical...
| Модель | AC220V-5KW-РКД | AC220V-10KW-РКД | AC220V-15KW-РКД | AC220V-20KW-РКД | АК 380V-30KW-РКД | AC380V-50KW-РКД | АК 380V-60KW-РКД | АК 380V-100KW-РКД | АК 380V-200KW-РКД |
| Номинальная мощность | R = 5 кВт | R = 10 кВт | R = 15 кВт | R = 20 кВт | R = 30 кВт | R = 50 кВт | R = 60 кВт | R = 100 кВт | R = 200 кВт |
| РКД = 5КВА | RCD = 10 КВА | RCD = 15 КВА | RCD = 20 КВА | РКД = 30КВА | RCD = 50КВА | RCD=60КВА | RCD=100КВА | RCD=200КВА | |
| Входный ток | 0-22А | 0-45А | 0-45А | 0-90А | 0-45А | 0-300А | 0-450А | 0-600А | 0-750А |
| Размер (ширина * глубина * высота мм) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Вес | 50 кг | 80 кг | 100 кг | 130 кг | 200 кг | 300 кг | 350 кг | 450 кг | 550кг |
| Входное напряжение | AC220/230В | AC380/400В | |||||||
| Другое входное напряжение может быть настроено в соответствии с требованиями | |||||||||
| Минимальная нагрузка | 100 Вт | 100 Вт | 100 Вт | 100 Вт | 100 Вт | 1 кВт | 1 кВт | 1 кВт | 1 кВт |
| Другая минимальная мощность загрузки может быть настроена в соответствии с требованиями | |||||||||
| Общая точность | 3% (другие требования точности могут быть настроены в соответствии с требованиями) | ||||||||
| коэффициент мощности | PF = 0,6 ~ 1,0 | ||||||||
| пиковый коэффициент | от 2 до 3 | ||||||||
| Режим управления | Локальный ручный/удаленный хост-компьютер (локальный режим ручного управления: выключатель/кнопка/сенсорный экран трехсторонний опциональный, другие методы могут быть настроены по мере необходимости) | ||||||||
| Удаленный интерфейс | RS232/RS485/USB/RJ45/CAN/GPIB (другие режимы интерфейса могут быть настроены в соответствии с требованиями) | ||||||||
| Функция защиты | Защита от аварийной остановки, защита от перетемпературы, защита от блокировки нагрузки вентилятора, защита от заземления (выберите защиту от перенапряжения, защиту от перетока, защиту от короткого замыкания, перегрузку вентилятора, недостаточный объем воздуха) | ||||||||
| Рабочее питание | АЦ220В | AC220V / AC380V | |||||||
| Точность отображения | Уровень 0,5 (другая явная точность может быть настроена в соответствии с требованиями) | ||||||||
| Параметры отображения | Напряжение, ток, мощность, частота, коэффициент мощности и т.д. (другие явные методы могут быть настроены в соответствии с требованиями) | ||||||||
| Холодный уверенный способ | Бочный вход воздуха и верхний выход воздуха (другие методы выхода воздуха могут быть настроены в соответствии с требованиями) | ||||||||
| Уровень защиты | IP20 (другой уровень защиты может быть настроен в соответствии с требованиями) | ||||||||
| Внешний цвет | RAL7035 (другие цвета могут быть настроены в соответствии с требованиями) | ||||||||
| Рабочая температура | -10 ℃ ~ 55 ℃ | ||||||||
| Относительная влажность | ≤95%RH | ||||||||
| Высота | ≤ 2500 м | ||||||||
Банк нагрузки инвертора GROADA AC600V 25 кВт является специально разработанным решением для испытаний для производителей инверторов, лабораторий и инженеров силовой электроники, которые требуют точной, повторяемой и безопасной проверки производительности. Разработанный для современных возобновляемых источников энергии и хранения энергии, он обеспечивает контролируемую среду для имитации реальных условий эксплуатации и обеспечения того, чтобы инверторы соответствовали строгим стандартам надежности и эффективности.
По мере того как солнечные, аккумуляторные и микросетковые системы продолжают расширяться, надежность инверторов стала более важной, чем когда-либо. Профессиональный банк нагрузок имеет важное значение для проверки претензий по проекту, снижения риска сбоя и укрепления доверия клиентов.
Банк нагрузки инвертора - это точное устройство, которое применяет электрическую нагрузку к испытываемому инвертору безопасным, контролируемым образом. В отличие от пассивных полевых испытаний, которые подвергают оборудование непредсказуемым условиям, банк нагрузки обеспечивает стабильные и регулируемые нагрузки, что позволяет инженерам:
Измерение эффективности преобразования на разных уровнях нагрузки
Анализ теплового поведения инвертора при непрерывной работе
Проверка функций перетока, перенапряжения и защиты
Испытательные характеристики инвертора при сопротивляющих и реактивных нагрузках
Confirm grid-compliance functions such as anti-islanding and synchronization
This makes the GROADA AC600V 25 kW Load Bank an indispensable tool for inverter R&D, production quality assurance, and third-party certification.
600 V DC input and 25 kW power capacity — suitable for medium-scale PV and ESS inverters
Programmable load profiles — supports stepped, gradual, or dynamic load changes
Resistive, reactive, and inductive test modes — replicates real-world load conditions
Energy regenerative design — reduces wasted energy by feeding it back to the grid
High measurement accuracy — captures voltage, current, frequency, THD, and power factor with precision
Comprehensive protection — includes overcurrent, overvoltage, and thermal safeguards
Modular scalability — units can be combined for higher test power requirements
Industrial-grade reliability — robust cooling, durable construction, and long service life
By gradually stepping through load levels (10%, 20%, 50%, 100%), engineers can generate inverter efficiency curves and quantify power losses. This is essential for meeting regulatory requirements and optimizing design.
Sustained full-power operation simulates demanding field conditions. Engineers can verify cooling system performance, detect hot spots, and assess component aging over time.
Real electrical networks rarely operate with pure resistive loads. The ability to test with inductive or capacitive elements ensures accurate validation of power factor correction, stability, and reactive power handling.
Step loads, sudden drops, or rapid fluctuations test the robustness of inverter control loops. Load banks can uncover hidden weaknesses in firmware or protection systems that would otherwise appear only in the field.
Grid codes worldwide require inverters to handle abnormal conditions such as voltage dips, frequency shifts, or anti-islanding detection. A load bank allows safe simulation of these events to prove compliance with IEC, IEEE, and UL standards.
Solar Photovoltaic Inverters — verifying efficiency, MPP tracking, and safety under variable sunlight conditions
Energy Storage Systems (ESS) — testing bidirectional inverters and charge/discharge cycles
Microgrids and Hybrid Power Systems — ensuring reliable power sharing and seamless transitions
R&D Laboratories — supporting prototype evaluation and academic research in power electronics
Manufacturing QA — providing repeatable end-of-line testing before product shipment
Trusted Accuracy – Designed with precision instrumentation for reliable test results.
Energy Savings – Regenerative design minimizes waste and reduces operational costs.
Operator Safety – Integrated protections and emergency shutoffs ensure safe operation.
Flexibility – Adaptable to multiple inverter types, from residential PV to industrial storage.
Future-Proof – Modular capacity supports expansion as test demands grow.
The GROADA 25 kW Inverter Load Bank is engineered to support compliance testing with major global standards, including:
IEC 62116 – Test procedure of islanding prevention measures for grid-connected PV inverters
IEC 61000 – Electromagnetic compatibility requirements
IEEE 1547 – Standard for interconnection and interoperability of distributed resources
UL 1741 – Inverters, converters, and controllers for use in distributed energy resources
Meeting these standards is essential for manufacturers aiming to enter international markets with certified products.
GROADA specializes in advanced load bank solutions for the renewable energy and power electronics industries. Our engineering team brings years of field experience and technical expertise, ensuring products that combine innovation, durability, and cost efficiency.
By partnering with GROADA, customers gain more than equipment — they gain a trusted testing partner committed to quality, reliability, and global support.
The GROADA AC600V 25 kW Inverter Load Bank empowers inverter developers, manufacturers, and testing laboratories with a reliable, precise, and efficient tool for performance validation. From efficiency mapping to grid-compliance testing, it delivers the insights needed to design robust, safe, and market-ready inverters.
Investing in a professional load bank is not just about compliance — it is about ensuring long-term reliability, customer satisfaction, and competitive advantage in the fast-growing renewable energy sector.