Производитель банка нагрузки GROADA-AC120V-5KW-RCD
The GROADA AC120V-5KW RCD Load Bank is a high-precision testing device designed to simulate nonlinea...
| Модель | AC220V-5KW-РКД | AC220V-10KW-РКД | AC220V-15KW-РКД | AC220V-20KW-РКД | АК 380V-30KW-РКД | AC380V-50KW-РКД | АК 380V-60KW-РКД | АК 380V-100KW-РКД | АК 380V-200KW-РКД |
| Номинальная мощность | R = 5 кВт | R = 10 кВт | R = 15 кВт | R = 20 кВт | R = 30 кВт | R = 50 кВт | R = 60 кВт | R = 100 кВт | R = 200 кВт |
| РКД = 5КВА | RCD = 10 КВА | RCD = 15 КВА | RCD = 20 КВА | РКД = 30КВА | RCD = 50КВА | RCD=60КВА | RCD=100КВА | RCD=200КВА | |
| Входный ток | 0-22А | 0-45А | 0-45А | 0-90А | 0-45А | 0-300А | 0-450А | 0-600А | 0-750А |
| Размер (ширина * глубина * высота мм) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Вес | 50 кг | 80 кг | 100 кг | 130 кг | 200 кг | 300 кг | 350 кг | 450 кг | 550кг |
| Входное напряжение | AC220/230В | AC380/400В | |||||||
| Другое входное напряжение может быть настроено в соответствии с требованиями | |||||||||
| Минимальная нагрузка | 100 Вт | 100 Вт | 100 Вт | 100 Вт | 100 Вт | 1 кВт | 1 кВт | 1 кВт | 1 кВт |
| Другая минимальная мощность загрузки может быть настроена в соответствии с требованиями | |||||||||
| Общая точность | 3% (другие требования точности могут быть настроены в соответствии с требованиями) | ||||||||
| коэффициент мощности | PF = 0,6 ~ 1,0 | ||||||||
| пиковый коэффициент | от 2 до 3 | ||||||||
| Режим управления | Локальный ручный/удаленный хост-компьютер (локальный режим ручного управления: выключатель/кнопка/сенсорный экран трехсторонний опциональный, другие методы могут быть настроены по мере необходимости) | ||||||||
| Удаленный интерфейс | RS232/RS485/USB/RJ45/CAN/GPIB (другие режимы интерфейса могут быть настроены в соответствии с требованиями) | ||||||||
| Функция защиты | Защита от аварийной остановки, защита от перетемпературы, защита от блокировки нагрузки вентилятора, защита от заземления (выберите защиту от перенапряжения, защиту от перетока, защиту от короткого замыкания, перегрузку вентилятора, недостаточный объем воздуха) | ||||||||
| Рабочее питание | АЦ220В | AC220V / AC380V | |||||||
| Точность отображения | Уровень 0,5 (другая явная точность может быть настроена в соответствии с требованиями) | ||||||||
| Параметры отображения | Напряжение, ток, мощность, частота, коэффициент мощности и т.д. (другие явные методы могут быть настроены в соответствии с требованиями) | ||||||||
| Холодный уверенный способ | Бочный вход воздуха и верхний выход воздуха (другие методы выхода воздуха могут быть настроены в соответствии с требованиями) | ||||||||
| Уровень защиты | IP20 (другой уровень защиты может быть настроен в соответствии с требованиями) | ||||||||
| Внешний цвет | RAL7035 (другие цвета могут быть настроены в соответствии с требованиями) | ||||||||
| Рабочая температура | -10 ℃ ~ 55 ℃ | ||||||||
| Относительная влажность | ≤95%RH | ||||||||
| Высота | ≤ 2500 м | ||||||||
ВGROADA AC220V 15kW RCD Load Bank is designed for accurate simulation and testing of non-linear electrical loads. It combines resistive and capacitive elements to closely replicate real-world load conditions, making it an essential tool for engineers, data centers, and power system professionals. Its high precision, robust safety features, and adherence to international standards ensure reliable performance for all testing scenarios.
Dual Load Types: Integrates resistive and capacitive loads to emulate non-linear electrical behavior.
Adjustable Power Factor: Allows settings from 0.6 to 1.0 for flexible testing applications.
High Current Capacity: Supports up to 96A, suitable for rigorous operational tests.
Universal Voltage Compatibility: Optimized for 220V AC systems, with customizable options for different voltages.
Advanced Safety Protections: Includes overload, over-temperature, and short-circuit safeguards to ensure operational safety.
Тестирование генератора: Evaluates generator performance under complex, non-linear loads to guarantee operational stability.
UPS Systems Assessment: Simulates real-world load conditions to identify potential UPS performance issues.
Inverter and PV System Testing: Validates inverter and photovoltaic equipment efficiency and reliability.
Data Centers & Critical Infrastructure: Ensures uninterrupted and safe operation of mission-critical power systems.
The AC220V 15kW RCD Load Bank adheres to global standards, ensuring credibility and safety:
IEEE 1547 – Distributed energy resources testing.
ISO 8528-10 – Generator load acceptance tests.
IEC 62040 – Performance requirements for UPS systems.
This compliance demonstrates reliability and builds trust with engineers and technical decision-makers.
Высокоточное испытание: Simulates non-linear loads for realistic system evaluations.
Versatile & Adaptable: Compatible with a wide range of AC power systems.
Robust Safety Features: Protects both operators and equipment.
Прочное строительство: Engineered for intensive testing environments.
Удобная для пользователя операция: Simplified interface for easy monitoring and control.
| Спецификация | Подробности |
|---|---|
| Rated Capacity | 15kW Resistive / 15kVAR Capacitive |
| напряжение | AC 220V Single Phase |
| Максимальный ток | 96A |
| Частота | 50/60 Гц |
| Фактор мощности | 0.6 – 1.0 |
| Особенности защиты | Overload, Over-temperature, Short-circuit |
| Стандарты соответствия | IEEE 1547, ISO 8528-10, IEC 62040 |
ВGROADA AC220V 15kW RCD Load Bank delivers unmatched precision and safety for non-linear load testing. Trusted by professionals worldwide, it ensures accurate system evaluations, enhances equipment reliability, and supports safe operation of critical power systems.
Email: groada@163.com
Phone: +86 755 2333 9096
Location:Шэньчжэнь, Гуандун, Китай
GROADA is committed to advancing testing solutions that meet evolving industry standards and operational demands.