GROADA-AC380V-150KW-RL Банк сопротивляющей нагрузки
The GROADA-AC380V-150KW-RL resistive load bank is a high-performance testing device designed to simu...
| Модель | AC220V-10KVA-RL | АК 380В-30КВА-РЛ | АК 380В-60КВА-РЛ | АК 380В-100КВА-РЛ | АК 380В-300КВА-РЛ | АК 380В-500КВА-РЛ | АК 380В-1000КВА-РЛ |
| Номинальная мощность | РЛ = 10КВА | РЛ = 30КВА | РЛ=60КВА | РЛ=100КВА | RL = 300 КВА | РЛ = 500КВА | РЛ = 1000КВА |
| R = 10 кВт; L = 6КВА | R = 30 кВт; L = 18 КВА | R = 60 кВт; L = 36КВА | R = 100 кВт; L=60КВА | R = 300 кВт; L=180КВА | R = 500 кВт; L=300КВА | R = 1000кВт; L=600КВА | |
| Входный ток | 0-45А | 0-45А | 0-90А | 0-150А | 0-450А | 0-750А | 0-1500А |
| Размер (ширина * глубина * высота мм) | 480*600*277 | 480*600*360 | 500*750*1000 | 600*850*1000 | 700*1000*1650 | 1100*1400*1700 | 1100*1500*1900 |
| Вес | 25 кг | 40 кг | 80 кг | 130 кг | 250 кг | 550кг | 750 кг |
| Минимальная нагрузка | 100 Вт | 100 Вт | 100 Вт | 500 Вт | 1 кВт | 5кВт | 10 кВт |
| Другая минимальная мощность загрузки может быть настроена в соответствии с требованиями | |||||||
| Входное напряжение | AC220/230В | AC380/400В | |||||
| Другое входное напряжение может быть настроено в соответствии с требованиями | |||||||
| коэффициент мощности | PF = 0,8/1,0 (другой коэффициент мощности может быть настроен в соответствии с требованиями) | ||||||
| Общая точность | 3% (другие требования точности могут быть настроены в соответствии с требованиями) | ||||||
| Режим управления | Локальный ручный/удаленный хост-компьютер (локальный режим ручного управления: выключатель/кнопка/сенсорный экран трехсторонний опциональный, другие методы могут быть настроены по мере необходимости) | ||||||
| Удаленный интерфейс | RS232/RS485/USB/RJ45/CAN/GPIB (другие режимы интерфейса могут быть настроены в соответствии с требованиями) | ||||||
| Функция защиты | Защита от аварийной остановки, защита от перетемпературы, защита от блокировки нагрузки вентилятора, защита от заземления (выберите защиту от перенапряжения, защиту от перетока, защиту от короткого замыкания, перегрузку вентилятора, недостаточный объем воздуха) | ||||||
| Рабочее питание | АЦ220В | AC220V / 380V | АЦ380В | ||||
| Точность отображения | Уровень 0,5 (другая явная точность может быть настроена в соответствии с требованиями) | ||||||
| Параметры отображения | Напряжение, ток, мощность, частота, коэффициент мощности и т.д. (другие явные методы могут быть настроены в соответствии с требованиями) | ||||||
| Холодный уверенный способ | Бочный вход воздуха и верхний выход воздуха (другие методы выхода воздуха могут быть настроены в соответствии с требованиями) | ||||||
| Уровень защиты | IP20 (другой уровень защиты может быть настроен в соответствии с требованиями) | ||||||
| Внешний цвет | RAL7035 (другие цвета могут быть настроены в соответствии с требованиями) | ||||||
| Рабочая температура | -10 ℃ ~ 55 ℃ | ||||||
| Относительная влажность | ≤95%RH | ||||||
| Высота | ≤ 2500 м | ||||||
При вводе в эксплуатацию, обслуживании или проверке критически важных энергосистем вам нужно больше, чем просто нагрузка. Вам нужна точность, гибкость и уверенность в реальных условиях. ВGROADA AC600V 180 кВА RL Резистивно-индуктивный нагрузочный банкпоставляет надежную, проверенную на местах платформу для испытаний полноспектральных генераторов / UPS / энергосистем, объединяя элементы сопротивления и индуктивной нагрузки в одном компактном модульном решении.
Моделируя как реальные (сопротивляющие), так и реактивные (индуктивные) нагрузки (обычно с целевым коэффициентом мощности, таким как 0,8), этот банк нагрузки RL помогает вам проверить стабильность напряжения системы, реакцию тока, переходное поведение и полную способность генератора до фактического развертывания.
Поддерживает сопротивляющую нагрузку (для реальной мощности) и индуктивную нагрузку (для отстаивающей реактивной мощности), что позволяет более реалистичное стрессовое испытание системы питания.
Может поставить тестирование в0.8 power factor by combining resistive and inductive sections, a commonly accepted standard for generator acceptance tests.
Offers flexible operation: resistive-only mode, inductive-only mode, or combined RL mode as required.
Rated for 600 V AC input, three-phase (other voltages available upon request).
Rated capacity: 180 kVA, typically meaning ~144 kW resistive + ~108 kVAR inductive (depending on configuration).
Load steps as fine as 100 W / 100 VAR (or higher granularity options), allowing precise load modulation.
Accuracy: ±3% (customizable to tighter tolerances on request).
Display & monitoring: shows voltage, current, real and reactive power, frequency, power factor, etc.
Control options: Local manual (breakers, buttons, touch panel) or remote interface (RS232 / RS485 / USB / RJ45 / CAN / GPIB) — enabling integration into test rigs or SCADA systems.
Emergency-stop (E-stop) protection to instantly remove load under critical conditions.
Over-temperature, fan failure, over-current, short circuit, and insufficient air flow protection.
Grounding protection and isolation to ensure safe operation.
IP rating (e.g. IP20 standard) (optional upgrades for harsher environments).
Thermal management: side air intake / top exhaust, modular airflow design to reduce hotspots.
Designed to operate over –10 °C to +55 °C ambient, up to ~2,500 m altitude.
Enclosure constructed from heavy-gauge steel, powder-coated for corrosion resistance.
Modular sections for resistive and inductive elements; scalable and maintainable.
Forklift channels or lifting eyes provided for ease of installation.
Compact footprint given the power class, enabling rooftop, pad, or indoor installation.
Customization: different frame sizes, color (RAL family), door arrangements, cooling layouts.
Generator Commissioning & Load Acceptance Tests
Validate that your generator set can sustain rated kVA, voltage regulation, transient response, and reactive load behavior before it enters service.
UPS / Power System Integration Testing
Emulate real-world loads (including reactive loads such as motors and inductive circuits) to ensure the UPS and switchgear respond correctly under full stress.
Parallel Generator Synchronization & Load Sharing
Use the RL load bank to balance and test load sharing across multiple gensets, ensuring stability during parallel operations.
Routine Preventive Maintenance / Health Checks
Regular load banking helps avoid “wet stacking” (in diesel gensets running light) and can burn off carbon buildup, improving fuel efficiency and engine life.
Many industry guidelines recommend at least annual full-load testing under rated power factor.
Design Validation & R&D in Power Systems
For OEMs, labs, or integrators, the RL load bank is essential when developing alternators, power converters, controllers, or new power architectures (e.g. microgrids).
Data Centers, Telecom, Critical Infrastructure
In critical facilities where downtime is not tolerated, you must ensure every component performs under combined resistive and reactive stress.
Expertise & Authority: GROADA has decades of experience in power testing equipment, certified by relevant quality and safety standards.
Certifications & Quality Control: Each RL unit undergoes factory calibration, burn-in, and full functional testing before delivery.
Transparent Specifications: All electrical, thermal, mechanical parameters are documented and open to customer review or 3rd-party validation.
Post-Sales Support & Warranty: GROADA offers technical support, spare parts, and extended warranties — helping clients confidently deploy and maintain systems.
Integrated dual-mode design eliminates the need to buy separate resistive and inductive banks — saving cost, footprint, and complexity.
Fine load step resolution and remote control capability give customers flexibility for nuanced stress tests.
Strong reliability and proven design reduce lifetime maintenance and downtime risk.
Customs and configurations possible: if your project needs a custom voltage, power factor, enclosure, or interface, GROADA can accommodate.