GROADA-AC220V-15KW-RLC Производитель банка нагрузки
The GROADA AC220V 15KW RLC Load Bank is engineered to provide comprehensive simulation of real-world...
| Модель | AC220V-10KVA-РЛК | AC380V-30KVA-РЛК | AC380V-60KVA-РЛК | AC380V-100KVA-РЛК | AC380V-200KVA-РЛК | AC380V-300KVA-РЛК |
| Номинальная мощность | РЛК = 10 КВА | РЛК = 30КВА | РЛК=60КВА | РЛК=100КВА | РЛК=200КВА | RLC = 300 КВА |
| R = 10 кВт; L = 10 КВА С = 10КВА | R = 30 кВт; L=30КВА; С=30КВА | R = 60 кВт; L = 60 КВА; С=60КВА | R = 100 кВт; L = 100 КВА; С=100КВА | R = 200 кВт; L = 200 КВА; С=200КВА | R = 300 кВт; L = 300 КВА; С=300КВА | |
| Другая мощность может быть настроена в соответствии с требованиями | ||||||
| Размер (ширина * глубина * высота мм) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| Вес | 120 кг | 380кг | 580кг | 880 кг | 1500 кг | 2500кг |
| Входное напряжение | AC220/230В | AC380/400В | ||||
| Другое входное напряжение может быть настроено в соответствии с требованиями | ||||||
| Входный ток | 0-45А | 0-45А | 0-90А | 0-150А | 0-300А | 0-450А |
| Минимальная нагрузка | R = 100 Вт; L=100VA; С=100ВА | R = 100 Вт; L=100VA; С=100ВА | R = 100 Вт; L=100VA; С=100ВА | R = 100 Вт; L=100VA; С=100ВА | R = 1 кВт; L = 1 КВА; С=1КВА | R = 1 кВт; L = 1 КВА; С=1КВА |
| Другая минимальная мощность загрузки может быть настроена в соответствии с требованиями | ||||||
| коэффициент мощности | PF = 0,1 ~ 1,0 (другой коэффициент мощности может быть настроен в соответствии с требованиями) | |||||
| Общая точность | 3% (другие требования точности могут быть настроены в соответствии с требованиями) | |||||
| Режим управления | Локальный ручный/удаленный хост-компьютер (локальный режим ручного управления: выключатель/кнопка/сенсорный экран трехсторонний опциональный, другие методы могут быть настроены по мере необходимости) | |||||
| Удаленный интерфейс | RS232/RS485/USB/RJ45/CAN/GPIB (другие режимы интерфейса могут быть настроены в соответствии с требованиями) | |||||
| Функция защиты | Защита от аварийной остановки, защита от перетемпературы, защита от блокировки нагрузки вентилятора, защита от заземления (выберите защиту от перенапряжения, защиту от перетока, защиту от короткого замыкания, перегрузку вентилятора, недостаточный объем воздуха) | |||||
| Рабочее питание | АЦ220В | AC220V / 380V | АЦ380В | |||
| Точность отображения | Уровень 0,5 (другая явная точность может быть настроена в соответствии с требованиями) | |||||
| Параметры отображения | Напряжение, ток, мощность, частота, коэффициент мощности и т.д. (другие явные методы могут быть настроены в соответствии с требованиями) | |||||
| Холодный уверенный способ | Бочный вход воздуха и верхний выход воздуха (другие методы выхода воздуха могут быть настроены в соответствии с требованиями) | |||||
| Уровень защиты | IP20 (другой уровень защиты может быть настроен в соответствии с требованиями) | |||||
| Внешний цвет | RAL7035 (другие цвета могут быть настроены в соответствии с требованиями) | |||||
| Рабочая температура | -10 ℃ ~ 55 ℃ | |||||
| Относительная влажность | ≤95%RH | |||||
| Высота | ≤ 2500 м | |||||
The GROADA RLC Load Bank is a cutting-edge solution designed for rigorous testing of electrical power systems. By accurately simulating resistive (R), inductive (L), and capacitive (C) loads, this load bank provides a realistic representation of real-world operating conditions. It is an essential tool for engineers, technicians, and facility managers seeking to ensure the reliability, efficiency, and safety of generators, UPS systems, and other critical power equipment.
In today’s fast-evolving energy landscape, where renewable integration, critical infrastructure, and industrial automation demand stable and reliable electricity, the GROADA RLC Load Bank delivers precision, versatility, and compliance with global standards.
The GROADA RLC Load Bank can simultaneously apply resistive, inductive, and capacitive loads. This ensures that power systems are tested under conditions that closely mimic real operational environments, including fluctuating loads, harmonics, and varying power factors.
Modern electrical systems require flexible load testing. The GROADA load bank allows power factor adjustments from 0.1 to 1.0, enabling the evaluation of system performance under lagging, leading, and unity power factors. This is particularly crucial for industrial equipment, UPS systems, and renewable energy sources.
Designed for global applications, the RLC Load Bank supports both single-phase and three-phase AC systems:
Single-phase: 120V, 220V, 230V, 240V (50/60Hz)
Three-phase: 208V, 380V, 400V, 415V (50/60Hz)
This makes it suitable for international deployments across data centers, industrial plants, and telecommunication facilities.
Equipped with high-precision digital meters, the load bank monitors:
Voltage and current
Active, reactive, and apparent power
Power factor
Energy consumption
Частота
These real-time measurements allow engineers to make informed decisions and validate system performance accurately.
The GROADA RLC Load Bank offers both local and remote control:
Local Operation: Intuitive touchscreen interface for easy load adjustment.
Remote Operation: Full computer-based control for monitoring, scheduling, and data logging, improving operational efficiency and safety.
Resistive load accuracy: ±5%
Inductive and capacitive load accuracy: ±10%
These specifications guarantee precise load application, ensuring test results are reliable and reproducible.
The GROADA RLC Load Bank is widely used across multiple sectors:
Uninterrupted power is critical in data centers. The RLC Load Bank allows operators to test backup generators and UPS systems under full-load conditions, ensuring seamless operation during power outages.
Telecom facilities depend on emergency power systems for network continuity. The load bank enables rigorous testing of power infrastructure, preventing service interruptions and safeguarding critical communication lines.
Production lines and heavy machinery rely on stable power. The GROADA load bank evaluates system robustness, identifies weaknesses, and minimizes downtime risks, ultimately protecting operational continuity and revenue.
Mission-critical operations require power systems that perform flawlessly under extreme conditions. The RLC Load Bank validates generators, UPS, and control systems, ensuring readiness in defense and aerospace applications.
As solar, wind, and hybrid energy solutions grow in adoption, testing their interaction with grid systems becomes essential. The RLC Load Bank simulates variable loads to evaluate system stability, voltage regulation, and power factor correction.
The GROADA RLC Load Bank adheres to globally recognized standards:
IEEE 1547: Distributed energy resource interconnection and performance testing.
IEEE 112.3 & 112.5: UPS performance verification standards.
NFPA 110: Emergency and standby power system testing and maintenance.
ISO 8528: Reciprocating engine-driven generator testing procedures.
IEC 62040: Performance and test requirements for UPS systems.
UL 1008: Safety requirements for transfer switches.
These certifications ensure that testing meets regulatory requirements, enabling safe deployment in diverse industries worldwide.
By simulating real operational loads, potential weaknesses in generators, alternators, batteries, and control panels are detected before they cause system failures.
Proactive testing reduces unexpected maintenance costs and extends equipment lifespan by identifying issues early.
Regular load testing ensures uninterrupted power supply, critical in healthcare, data centers, and telecom facilities.
Meeting ISO, IEEE, NFPA, and UL standards ensures organizations maintain compliance and safety across all operations.
By preventing downtime and optimizing power system performance, organizations save on energy costs, maintenance expenses, and emergency repair charges.
| Параметр | Спецификация |
|---|---|
| Тип нагрузки | Resistive, Inductive, Capacitive |
| Фактор мощности | 0.1 – 1.0 Adjustable |
| напряжение | Single-phase 120V/220V/230V/240V, Three-phase 208V/380V/400V/415V |
| Частота | 50/60Гц |
| Measurement Accuracy | ±5% R, ±10% L/C |
| Control | Local touchscreen, Remote computer control |
| Dimensions | Customizable per model |
| Cooling | Forced air or natural convection options |
| Особенности безопасности | Overload protection, emergency stop, thermal sensors |
GROADA has decades of experience in designing and manufacturing load banks trusted by industries worldwide. Our products are:
Reliable: Engineered for precision and long-term durability.
Flexible: Suitable for a wide range of power systems and international voltage standards.
Safe: Compliant with global electrical safety standards.
User-Friendly: Advanced digital interface for easy monitoring and control.
Organizations from data centers to military bases rely on GROADA load banks to validate and maintain their electrical systems efficiently.
In an era where uninterrupted power supply is mission-critical, the GROADA RLC Load Bank provides unmatched precision, versatility, and reliability. By simulating realistic electrical loads, it ensures that generators, UPS systems, and industrial power infrastructures operate optimally under any condition.
Elevate your power testing capabilities with GROADA – the professional choice for engineers and organizations that demand accuracy, safety, and performance.