The GROADA AC120V-5KW RCD Load Bank is a high-precision testing device designed to simulate nonlinea...
| Модель | AC220V-5KW-РКД | AC220V-10KW-РКД | AC220V-15KW-РКД | AC220V-20KW-РКД | АК 380V-30KW-РКД | AC380V-50KW-РКД | АК 380V-60KW-РКД | АК 380V-100KW-РКД | АК 380V-200KW-РКД |
| Номинальная мощность | R = 5 кВт | R = 10 кВт | R = 15 кВт | R = 20 кВт | R = 30 кВт | R = 50 кВт | R = 60 кВт | R = 100 кВт | R = 200 кВт |
| РКД = 5КВА | RCD = 10 КВА | RCD = 15 КВА | RCD = 20 КВА | РКД = 30КВА | RCD = 50КВА | RCD=60КВА | RCD=100КВА | RCD=200КВА | |
| Входный ток | 0-22А | 0-45А | 0-45А | 0-90А | 0-45А | 0-300А | 0-450А | 0-600А | 0-750А |
| Размер (ширина * глубина * высота мм) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| Вес | 50 кг | 80 кг | 100 кг | 130 кг | 200 кг | 300 кг | 350 кг | 450 кг | 550кг |
| Входное напряжение | AC220/230В | AC380/400В | |||||||
| Другое входное напряжение может быть настроено в соответствии с требованиями | |||||||||
| Минимальная нагрузка | 100 Вт | 100 Вт | 100 Вт | 100 Вт | 100 Вт | 1 кВт | 1 кВт | 1 кВт | 1 кВт |
| Другая минимальная мощность загрузки может быть настроена в соответствии с требованиями | |||||||||
| Общая точность | 3% (другие требования точности могут быть настроены в соответствии с требованиями) | ||||||||
| коэффициент мощности | PF = 0,6 ~ 1,0 | ||||||||
| пиковый коэффициент | от 2 до 3 | ||||||||
| Режим управления | Локальный ручный/удаленный хост-компьютер (локальный режим ручного управления: выключатель/кнопка/сенсорный экран трехсторонний опциональный, другие методы могут быть настроены по мере необходимости) | ||||||||
| Удаленный интерфейс | RS232/RS485/USB/RJ45/CAN/GPIB (другие режимы интерфейса могут быть настроены в соответствии с требованиями) | ||||||||
| Функция защиты | Защита от аварийной остановки, защита от перетемпературы, защита от блокировки нагрузки вентилятора, защита от заземления (выберите защиту от перенапряжения, защиту от перетока, защиту от короткого замыкания, перегрузку вентилятора, недостаточный объем воздуха) | ||||||||
| Рабочее питание | АЦ220В | AC220V / AC380V | |||||||
| Точность отображения | Уровень 0,5 (другая явная точность может быть настроена в соответствии с требованиями) | ||||||||
| Параметры отображения | Напряжение, ток, мощность, частота, коэффициент мощности и т.д. (другие явные методы могут быть настроены в соответствии с требованиями) | ||||||||
| Холодный уверенный способ | Бочный вход воздуха и верхний выход воздуха (другие методы выхода воздуха могут быть настроены в соответствии с требованиями) | ||||||||
| Уровень защиты | IP20 (другой уровень защиты может быть настроен в соответствии с требованиями) | ||||||||
| Внешний цвет | RAL7035 (другие цвета могут быть настроены в соответствии с требованиями) | ||||||||
| Рабочая температура | -10 ℃ ~ 55 ℃ | ||||||||
| Относительная влажность | ≤95%RH | ||||||||
| Высота | ≤ 2500 м | ||||||||
ВGROADA AC220V 1.2kW/10-Group RCD Load Bank is engineered to provide precise, reliable simulation of нелинейные электрические нагрузки, ensuring power systems are thoroughly tested under real-world operating conditions. Nonlinear loads, common in modern electronics, servers, and industrial equipment, create complex current and voltage characteristics that can stress power supplies. This load bank is designed to replicate these conditions, giving engineers and facility managers a dependable tool for evaluating and validating power infrastructure performance.
Дляdata centers, uninterruptible power supplies (UPS)илиinverter systems, this RCD load bank ensures operational stability, safety, and long-term equipment reliability.
The load bank consists of 10 independent 120W resistive units, allowing incremental load testing and easy scaling to match the system under evaluation.
Users can combine or isolate groups to simulate various load patterns, from light to full capacity.
Precisely control the коэффициент мощности to mimic real-world nonlinear load scenarios.
Supports a broad range of testing conditions, ensuring comprehensive evaluation of power sources.
Built-in protections include overload, short circuitиover-temperature safeguards.
Ensures safe operation during testing, protecting both the load bank and the connected equipment.
Оснащенdigital display providing real-time monitoring of voltage, current, and load conditions.
Intuitive interface allows quick setup, accurate measurement, and detailed data logging.
The GROADA RCD Load Bank is indispensable for testing and validating power systems in environments with complex load demands, including:
Центры обработки данных: Accurately simulate server farms and networking equipment to ensure uninterrupted operation under nonlinear load conditions.
Системы UPS: Validate performance and efficiency, confirming backup power remains stable during varying load conditions.
Inverter Systems: Assess the capacity of inverters to handle dynamic and fluctuating loads without compromising output stability.
Industrial and Laboratory Environments: Ideal for R&D, preventive maintenance, and compliance testing of electrical systems.
| Параметр | Спецификация |
|---|---|
| Номинальное напряжение | переменный 220 В |
| Total Power Capacity | 1.2kW |
| Load Units | 10 independent 120W resistive modules |
| Особенности защиты | Overload, short circuit, over-temperature |
| Интерфейс управления | Digital display with manual adjustment options |
| Фактор мощности | Adjustable to simulate various load scenarios |
Вload bank market is experiencing significant growth, driven by the increasing complexity of electrical systems and demand for reliable power testing.
The global market is projected to expand from USD 288.17 million in 2024 to USD 387.15 million by 2032, with a CAGR of 3.70%.
North America remains a key region, with high adoption in data centers, telecommunication facilitiesиindustrial plants.
The rise of sensitive electronic equipment and stringent power reliability standards is pushing organizations to invest in precision load testing solutions.
Reliability: Designed for continuous operation under challenging conditions.
Precision: Accurately simulates nonlinear loads, ensuring valid and repeatable test results.
Safety: Advanced protection systems reduce risk to both operators and equipment.
Versatility: Suitable for diverse applications, from laboratory testing to industrial-scale operations.
ВGROADA AC220V 1.2kW/10-Group RCD Load Bank is a comprehensive solution for modern power system testing, providing engineers with the confidence that their equipment can withstand complex load conditions, maintain stability, and operate safely.