GROADA-AC380V-50KW-R/RCD 변환기 부하 은행
The GROADA AC380V-50KW-R/RCD inverter test load bank is a high-performance testing device specifical...
| 모델 | AC220V-5KW-RCD는 | AC220V-10KW-RCD는 | AC220V-15KW-RCD는 | AC220V-20KW-RCD는 | AC380V는 -30KW-RCD | AC380V는 -50KW-RCD | AC380V는 - 60KW-RCD | AC380V는 - 100KW-RCD | AC380V는 -200KW-RCD |
| 정격 전력 | R = 5KW | R = 10KW | R = 15KW | R = 20KW | R = 30KW | R = 50KW | R = 60KW | R = 100KW | R = 200KW |
| RCD = 5KVA | RCD = 10KVA | RCD = 15KVA | RCD = 20KVA | RCD = 30KVA | RCD = 50KVA | RCD = 60KVA | RCD = 100KVA | RCD = 200KVA | |
| 입력 현재 | 0-22A | 0-45A | 0-45A | 0-90A | 0-45A | 0-300A | 0-450A | 0-600A | 0-750A |
| 크기 (폭 * 깊이 * 높이 mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| 무게 | 50KG의 | 80KG의 | 100KG의 | 130KG의 | 200KG의 | 300KG의 | 350KG의 | 450KG의 | 550KG의 |
| 입력 전압 | AC220 / 230V | AC380/400V | |||||||
| 다른 입력 전압은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | |||||||||
| 최소 부하 | 100W | 100W | 100W | 100W | 100W | 1KW | 1KW | 1KW | 1KW |
| 다른 최소 적재 힘은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | |||||||||
| 전반적인 정확도 | 3% (다른 정확도 요구 사항은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 전력 요소 | PF = 0.6 ~ 1.0 | ||||||||
| 최고 계수 | 2에서 3까지 | ||||||||
| 제어 모드 | 지역 수동/원격 호스트 컴퓨터 (지역 수동 제어 모드: 차단기/버튼/터치 스크린 선택적 3 방향, 다른 방법은 필요에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 원격 인터페이스 | RS232/RS485/USB/RJ45/CAN/GPIB (다른 인터페이스 형태는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 보호 기능 | 비상 정지 보호, 과온 보호, 팬 부하 인터로크 보호, 접지 보호 (과전압 보호, 과전류 보호, 단회로 보호, 팬 과부하, 부족한 공기 용량을 선택하십시오) | ||||||||
| 작동 전원 공급 | AC220V는 | AC220V / AC380V | |||||||
| 표시 정확도 | 0.5 수준 (다른 명시적인 정밀도는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 표시 매개 변수 | 전압, 전류, 힘, 주파수, 전력 요인 등. (다른 명시적인 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 차가운 확실한 방법 | 측면 공기 입구 및 위 공기 출구 (다른 공기 출구 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 보호 수준 | IP20 (다른 보호 수준은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 외관 색깔 | RAL7035 (다른 색깔은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 작동 온도 | -10 ℃ ~ 55 ℃ | ||||||||
| 상대 습도 | ≤95%RH | ||||||||
| 고도 | ≤ 2500 m | ||||||||
GROADA의 AC120V 50 kVA RCD 인버터 로드 GROADA는 고전력 인버터 로드 테스트 및 검증을 위해 특별히 만들어졌습니다.제조업체, 시스템 통합업체 및 테스트 연구소가 전체 부하, 부분 부하, 일시적 및 라이드-스루 테스트를 안정적이고 안전하게 실행할 수 있습니다.이 로드 이 실제 조건에서 인버터 성능을 검증하여 안정적인 출력, 준수 및 장기 신뢰성을 보장합니다.
고전력 처리
이 로드 벤크는 AC120V에서 최대 50 kVA의 연속적이고 동적 로드를 지원하여 중대형 인버터 또는 인버터 배열에 적합합니다.
RCD 보호 통합
시험 중에 누출이나 지상 결함으로부터 보호하기 위해 RCD (잔류 전류 장치) 안전 기능을 포함합니다.
조절 가능한 부하 수준
사용자는 증가적인 단계적 또는 지속적으로 변수 가능한 부하를 정의할 수 있으며 가량, 중간 및 완전 운영 조건의 시뮬레이션을 가능하게 합니다.
빠른 응답 &로드 전환
빠른 부하 변화 또는 단계 부하를 시뮬레이션 할 수 있으며, 이는 인버터 일시적 반응, 복구 및 라이드-스루 성능을 검증하는 데 필수적입니다.
정밀 모니터링 &측정
통합 측정 모듈은 전압, 전류, 전력 요소, 효율성, THD, 통통광 및 파형 왜곡을 실시간으로 캡처합니다.
열 관리 &보호
온도 센서, 과온 보호 및 냉각 인프라를 갖추어 장기간 테스트에서 안정적인 작동을 보장합니다.
모듈 &확장 가능한 디자인
단위는 더 높은 전력 등급이나 병렬 작동을 위해 확장되거나 모듈화될 수 있으며 유연한 스케일링을 허용합니다.
표준 준수
안전 및 측정 표준 (예: IEC, UL 등)을 충족하도록 설계되어 테스트 환경이 신뢰할 수 있도록 보장됩니다.
인증된 인버터조차도 실제 또는 스트레스 조건에서 실패할 수 있습니다.1/3의 PV 인버터가 핵심 성능 또는 안전 테스트에 실패했습니다.IEC/UL 인증이 있음에도 불구하고.
Using a load bank helps you uncover issues—such as thermal instability, waveform distortion, overcurrent trips, or inability to ride through transients—before field deployment.
To meet grid-codes or certification requirements (e.g. IEEE 1547.1 for distributed energy resources), inverter systems must pass a variety of stress and dynamic tests.
A robust load bank is essential to simulate worst-case grid or load conditions.
In production or R&D, load banks facilitate fast, repeatable testing cycles. This is especially valuable in automotive, PV, ESS (energy storage systems), or industrial applications where inverter reliability is critical.
글로벌end-of-line inverter testing market was valued at about USD 1.27 billion in 2024 and is expected to reach USD 2.85 billion by 2033, a strong CAGR of ≈ 9.4 %.
ThePV inverter testing system market alone was valued at around USD 220 million in 2024 and is projected to grow to ~USD 450 million by 2033.
The overall inverter market (across sectors) is huge — valued at over USD 22 billion in 2024 and forecast to exceed USD 70+ billion by 2032, driven by renewables, electrification, and energy storage expansion.
These trends underscore that high-quality test infrastructure (like load banks) is increasingly indispensable.
Full-Load Endurance Tests
Run the inverter at rated output for prolonged periods to verify thermal stability, component degradation, and long-term reliability.
Partial-Load & Efficiency Mapping
Apply loads at, say, 25%, 50%, 75%, and 100% to map efficiency curves, power factor, and losses across operating range.
Transient & Step-Load Tests
Introduce sudden load changes (e.g. 10% → 80% → 30%) and monitor how the inverter handles transient events, recovery time, and waveform stability.
Ride-Through / Fault Simulation
Simulate grid disturbances, faults, or momentary interruptions and evaluate how the inverter maintains output or recovers — critical for compliance and stability.
Harmonic / Distortion Testing
Introduce non-pure loads or harmonic injection and assess how the inverter performs under nonlinear or distorted loads.
Multi-Unit / Parallel System Testing
For systems with multiple parallel inverter modules, test how they share load, respond to imbalance, or handle switching dynamics.
Load Type & Modeling
Use a mix of resistive, inductive, and capacitive loads to emulate real-world conditions. Many inverter tests require reactive power handling and realistic load emulation.
Instrumentation Accuracy
Ensure measurement modules are precise (e.g. ±0.1% class or better), especially for efficiency and power factor comparisons.
Thermal Derating
At high power, ambient temperature and internal heating can reduce effective load capacity — plan for margin or active cooling.
Transient Speed & Control Loop Interaction
The load bank must respond quickly and smoothly to test pulses so the inverter’s control system isn’t tricked by overly slow transitions.
Isolation & Safety
Proper galvanic isolation, overcurrent protection, and residual current detection (RCD) must be in place to safeguard test hardware and personnel.
Data Logging & Analysis
Capture high-resolution data (sampling ≥ 1 kHz or more) and provide software tools to analyze instability, harmonics, voltage dips, or anomalies.
Tailored for High-Power Inverters: Many load banks top out at a few tens of kW; 50 kVA at AC120V positions this unit well above standard commodity test rigs.
안전 중심 디자인: Built-in RCD protection helps mitigate faults and enhances confidence in testing environments.
Scalability & Flexibility: Its modular architecture allows future upgrades or parallel operation for larger systems.
Precision & Responsiveness: Designed for fast load steps and stable control, ideal for dynamic performance tests.
Proven Technology & Support: Backed by GROADA’s expertise and experience in power electronics testing.