인버터 시험 부하 은행

GROADA-AC120V-50KVA-RCD 변환기 부하 은행

★★★★★
주요 제품:
  • AC 부하 은행: R/RL/RLC/RCD
  • DC 부하 은행: DC5V - 2000V, 0A - 5000A


모델AC220V-5KW-RCD는AC220V-10KW-RCD는AC220V-15KW-RCD는AC220V-20KW-RCD는AC380V는 -30KW-RCDAC380V는 -50KW-RCDAC380V는 - 60KW-RCDAC380V는 - 100KW-RCDAC380V는 -200KW-RCD
정격 전력R = 5KWR = 10KWR = 15KWR = 20KWR = 30KWR = 50KWR = 60KWR = 100KWR = 200KW
RCD = 5KVARCD = 10KVARCD = 15KVARCD = 20KVARCD = 30KVARCD = 50KVARCD = 60KVARCD = 100KVARCD = 200KVA
입력 현재0-22A0-45A0-45A0-90A0-45A0-300A0-450A0-600A0-750A
크기 (폭 * 깊이 * 높이 mm)500*600*800500*600*1000500*600*1100500*750*1100600*850*1400600*850*1600600*850*1850700*1000*18001100*1400*1800
무게50KG의80KG의100KG의130KG의200KG의300KG의350KG의450KG의550KG의
입력 전압AC220 / 230VAC380/400V
다른 입력 전압은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다
최소 부하100W100W100W100W100W1KW1KW1KW1KW
다른 최소 적재 힘은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다
전반적인 정확도3% (다른 정확도 요구 사항은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다)
전력 요소PF = 0.6 ~ 1.0
최고 계수2에서 3까지
제어 모드지역 수동/원격 호스트 컴퓨터 (지역 수동 제어 모드: 차단기/버튼/터치 스크린 선택적 3 방향, 다른 방법은 필요에 따라 주문을 받아서 만들어질 수 있습니다)
원격 인터페이스RS232/RS485/USB/RJ45/CAN/GPIB (다른 인터페이스 형태는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다)
보호 기능비상 정지 보호, 과온 보호, 팬 부하 인터로크 보호, 접지 보호 (과전압 보호, 과전류 보호, 단회로 보호, 팬 과부하, 부족한 공기 용량을 선택하십시오)
작동 전원 공급AC220V는AC220V / AC380V
표시 정확도0.5 수준 (다른 명시적인 정밀도는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다)
표시 매개 변수전압, 전류, 힘, 주파수, 전력 요인 등. (다른 명시적인 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다)
차가운 확실한 방법측면 공기 입구 및 위 공기 출구 (다른 공기 출구 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다)
보호 수준IP20 (다른 보호 수준은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다)
외관 색깔RAL7035 (다른 색깔은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다)
작동 온도-10 ℃ ~ 55 ℃
상대 습도 ≤95%RH
고도 ≤ 2500 m


GROADA AC120V 50 kVA RCD 인버터 부하 은행 — 대형 인버터를 위한 신뢰할 수 있는 부하 테스트


소개 / 간략한 요약 (두 번째 단락)

GROADA의 AC120V 50 kVA RCD 인버터 로드 GROADA는 고전력 인버터 로드 테스트 및 검증을 위해 특별히 만들어졌습니다.제조업체, 시스템 통합업체 및 테스트 연구소가 전체 부하, 부분 부하, 일시적 및 라이드-스루 테스트를 안정적이고 안전하게 실행할 수 있습니다.이 로드 이 실제 조건에서 인버터 성능을 검증하여 안정적인 출력, 준수 및 장기 신뢰성을 보장합니다.


주요 특징 &기능

  • 고전력 처리
    이 로드 벤크는 AC120V에서 최대 50 kVA의 연속적이고 동적 로드를 지원하여 중대형 인버터 또는 인버터 배열에 적합합니다.

  • RCD 보호 통합
    시험 중에 누출이나 지상 결함으로부터 보호하기 위해 RCD (잔류 전류 장치) 안전 기능을 포함합니다.

  • 조절 가능한 부하 수준
    사용자는 증가적인 단계적 또는 지속적으로 변수 가능한 부하를 정의할 수 있으며 가량, 중간 및 완전 운영 조건의 시뮬레이션을 가능하게 합니다.

  • 빠른 응답 &로드 전환
    빠른 부하 변화 또는 단계 부하를 시뮬레이션 할 수 있으며, 이는 인버터 일시적 반응, 복구 및 라이드-스루 성능을 검증하는 데 필수적입니다.

  • 정밀 모니터링 &측정
    통합 측정 모듈은 전압, 전류, 전력 요소, 효율성, THD, 통통광 및 파형 왜곡을 실시간으로 캡처합니다.

  • 열 관리 &보호
    온도 센서, 과온 보호 및 냉각 인프라를 갖추어 장기간 테스트에서 안정적인 작동을 보장합니다.

  • 모듈 &확장 가능한 디자인
    단위는 더 높은 전력 등급이나 병렬 작동을 위해 확장되거나 모듈화될 수 있으며 유연한 스케일링을 허용합니다.

  • 표준 준수
    안전 및 측정 표준 (예: IEC, UL 등)을 충족하도록 설계되어 테스트 환경이 신뢰할 수 있도록 보장됩니다.


왜 Inverter Load Bank을 사용합니까?

성능 보장 &신뢰성

인증된 인버터조차도 실제 또는 스트레스 조건에서 실패할 수 있습니다.1/3의 PV 인버터가 핵심 성능 또는 안전 테스트에 실패했습니다.IEC/UL 인증이 있음에도 불구하고.
Using a load bank helps you uncover issues—such as thermal instability, waveform distortion, overcurrent trips, or inability to ride through transients—before field deployment.

Compliance & Certification Support

To meet grid-codes or certification requirements (e.g. IEEE 1547.1 for distributed energy resources), inverter systems must pass a variety of stress and dynamic tests. 
A robust load bank is essential to simulate worst-case grid or load conditions.

Accelerated Validation & QA

In production or R&D, load banks facilitate fast, repeatable testing cycles. This is especially valuable in automotive, PV, ESS (energy storage systems), or industrial applications where inverter reliability is critical.

Market Growth & Demand

  • 글로벌end-of-line inverter testing market was valued at about USD 1.27 billion in 2024 and is expected to reach USD 2.85 billion by 2033, a strong CAGR of ≈ 9.4 %. 

  • ThePV inverter testing system market alone was valued at around USD 220 million in 2024 and is projected to grow to ~USD 450 million by 2033.

  • The overall inverter market (across sectors) is huge — valued at over USD 22 billion in 2024 and forecast to exceed USD 70+ billion by 2032, driven by renewables, electrification, and energy storage expansion. 

These trends underscore that high-quality test infrastructure (like load banks) is increasingly indispensable.


Typical Test Applications & Use Cases

  1. Full-Load Endurance Tests
    Run the inverter at rated output for prolonged periods to verify thermal stability, component degradation, and long-term reliability.

  2. Partial-Load & Efficiency Mapping
    Apply loads at, say, 25%, 50%, 75%, and 100% to map efficiency curves, power factor, and losses across operating range.

  3. Transient & Step-Load Tests
    Introduce sudden load changes (e.g. 10% → 80% → 30%) and monitor how the inverter handles transient events, recovery time, and waveform stability.

  4. Ride-Through / Fault Simulation
    Simulate grid disturbances, faults, or momentary interruptions and evaluate how the inverter maintains output or recovers — critical for compliance and stability.

  5. Harmonic / Distortion Testing
    Introduce non-pure loads or harmonic injection and assess how the inverter performs under nonlinear or distorted loads.

  6. Multi-Unit / Parallel System Testing
    For systems with multiple parallel inverter modules, test how they share load, respond to imbalance, or handle switching dynamics.


Technical Considerations & Best Practices

  • Load Type & Modeling
    Use a mix of resistive, inductive, and capacitive loads to emulate real-world conditions. Many inverter tests require reactive power handling and realistic load emulation. 

  • Instrumentation Accuracy
    Ensure measurement modules are precise (e.g. ±0.1% class or better), especially for efficiency and power factor comparisons.

  • Thermal Derating
    At high power, ambient temperature and internal heating can reduce effective load capacity — plan for margin or active cooling.

  • Transient Speed & Control Loop Interaction
    The load bank must respond quickly and smoothly to test pulses so the inverter’s control system isn’t tricked by overly slow transitions.

  • Isolation & Safety
    Proper galvanic isolation, overcurrent protection, and residual current detection (RCD) must be in place to safeguard test hardware and personnel.

  • Data Logging & Analysis
    Capture high-resolution data (sampling ≥ 1 kHz or more) and provide software tools to analyze instability, harmonics, voltage dips, or anomalies.


Why Choose the GROADA 50 kVA RCD Load Bank?

  • Tailored for High-Power Inverters: Many load banks top out at a few tens of kW; 50 kVA at AC120V positions this unit well above standard commodity test rigs.

  • 안전 중심 디자인: Built-in RCD protection helps mitigate faults and enhances confidence in testing environments.

  • Scalability & Flexibility: Its modular architecture allows future upgrades or parallel operation for larger systems.

  • Precision & Responsiveness: Designed for fast load steps and stable control, ideal for dynamic performance tests.

  • Proven Technology & Support: Backed by GROADA’s expertise and experience in power electronics testing.