GROADA-AC220V-15KW-RLC 부하 은행 제조 업체
The GROADA AC220V 15KW RLC Load Bank is engineered to provide comprehensive simulation of real-world...
| 모델 | AC220V-10KVA-RLC는 | AC380V-30KVA-RLC는 | AC380V-60KVA-RLC는 | AC380V-100KVA-RLC는 | AC380V-200KVA-RLC는 | AC380V-300KVA-RLC는 |
| 정격 전력 | RLC = 10KVA | RLC = 30KVA | RLC = 60KVA | RLC = 100KVA | RLC = 200KVA | RLC = 300KVA |
| R = 10KW;L = 10KVA C = 10KVA | R=30KW;L=30KVA; C = 30KVA | R=60KW;L=60KVA; C = 60KVA | R=100KW;L=100KVA; C = 100KVA | R=200KW;L=200KVA; C = 200KVA | R=300KW;L=300KVA; C = 300KVA | |
| 다른 힘은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | ||||||
| 크기 (폭 * 깊이 * 높이 mm) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| 무게 | 120KG의 | 380KG의 | 580KG의 | 880KG의 | 1500KG의 | 2500KG의 |
| 입력 전압 | AC220 / 230V | AC380/400V | ||||
| 다른 입력 전압은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | ||||||
| 입력 현재 | 0-45A | 0-45A | 0-90A | 0-150A | 0-300A | 0-450A |
| 최소 부하 | R = 100W;L=100VA; C = 100VA | R = 100W;L=100VA; C = 100VA | R = 100W;L=100VA; C = 100VA | R = 100W;L=100VA; C = 100VA | R = 1KW;L = 1KVA; C = 1KVA | R = 1KW;L = 1KVA; C = 1KVA |
| 다른 최소 적재 힘은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | ||||||
| 전력 요소 | PF = 0.1~1.0 (다른 전력 요인은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 전반적인 정확도 | 3% (다른 정확도 요구 사항은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 제어 모드 | 지역 수동/원격 호스트 컴퓨터 (지역 수동 제어 모드: 차단기/버튼/터치 스크린 선택적 3 방향, 다른 방법은 필요에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 원격 인터페이스 | RS232/RS485/USB/RJ45/CAN/GPIB (다른 인터페이스 형태는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 보호 기능 | 비상 정지 보호, 과온 보호, 팬 부하 인터로크 보호, 접지 보호 (과전압 보호, 과전류 보호, 단회로 보호, 팬 과부하, 부족한 공기 용량을 선택하십시오) | |||||
| 작동 전원 공급 | AC220V는 | AC220V / 380V | AC380V는 | |||
| 표시 정확도 | 0.5 수준 (다른 명시적인 정밀도는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 표시 매개 변수 | 전압, 전류, 힘, 주파수, 전력 요인 등. (다른 명시적인 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 차가운 확실한 방법 | 측면 공기 입구 및 위 공기 출구 (다른 공기 출구 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 보호 수준 | IP20 (다른 보호 수준은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 외관 색깔 | RAL7035 (다른 색깔은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 작동 온도 | -10 ℃ ~ 55 ℃ | |||||
| 상대 습도 | ≤95%RH | |||||
| 고도 | ≤ 2500 m | |||||
GROADA RLC 로드 GROADA RLC 로드 은행은 전기 전력 시스템의 엄격한 테스트를 위해 설계된 최첨단 솔루션입니다.저항 (R), 유도 (L) 및 용량 (C) 부하를 정확하게 시뮬레이션함으로써 이 부하 은행은 실제 운영 조건의 현실적인 표현을 제공합니다.그것은 발전기, UPS 시스템 및 기타 중요한 전력 장비의 신뢰성, 효율성 및 안전성을 보장하려는 엔지니어, 기술자 및 시설 관리자에게 필수적인 도구입니다.
재생 가능한 에너지 통합, 중요한 인프라 및 산업 자동화가 안정적이고 신뢰할 수 있는 전기를 요구하는 오늘날의 빠르게 진화하는 에너지 환경에서 GROADA RLC Load Bank은 정밀성, 다양성 및 글로벌 표준 준수를 제공합니다.
GROADA RLC 로드 GROADA RLC 로드 GROADA RLC 로드 GROADA RLC 로드 GROADA RLC 로드 GROADA RLC 로드 GROADA RLC 로드 GROA GROADA RLC 로드 GROADA RLC 로드 GROADA이렇게 하면 전력 시스템이 변동하는 부하, 하모니크 및 다양한 전력 요인을 포함한 실제 운영 환경을 밀접하게 모방하는 조건에서 테스트되도록 보장됩니다.
현대 전기 시스템은 유연한 부하 테스트를 필요로 합니다.GROADA 로드 GROADA 로드 GROADA 로드 GROADA 로드 GROADA 로드 GROADA 로드 GROADA 로드 GROADA 로드 GROADA 로드 GROAGROADA 로드 GROAGROADA 로드 GROADA 로드 GROADA 로드 GROADA 로드 로드 GROADA이것은 산업 장비, UPS 시스템 및 재생 가능한 에너지 원에서는 특히 중요합니다.
글로벌 애플리케이션을 위해 설계된 RLC 로드 RLC Load Bank은 단상 및 삼상 AC 시스템 모두를 지원합니다.
Single-phase: 120V, 220V, 230V, 240V (50/60Hz)
Three-phase: 208V, 380V, 400V, 415V (50/60Hz)
This makes it suitable for international deployments across data centers, industrial plants, and telecommunication facilities.
Equipped with high-precision digital meters, the load bank monitors:
Voltage and current
Active, reactive, and apparent power
Power factor
Energy consumption
주파수
These real-time measurements allow engineers to make informed decisions and validate system performance accurately.
The GROADA RLC Load Bank offers both local and remote control:
Local Operation: Intuitive touchscreen interface for easy load adjustment.
Remote Operation: Full computer-based control for monitoring, scheduling, and data logging, improving operational efficiency and safety.
Resistive load accuracy: ±5%
Inductive and capacitive load accuracy: ±10%
These specifications guarantee precise load application, ensuring test results are reliable and reproducible.
The GROADA RLC Load Bank is widely used across multiple sectors:
Uninterrupted power is critical in data centers. The RLC Load Bank allows operators to test backup generators and UPS systems under full-load conditions, ensuring seamless operation during power outages.
Telecom facilities depend on emergency power systems for network continuity. The load bank enables rigorous testing of power infrastructure, preventing service interruptions and safeguarding critical communication lines.
Production lines and heavy machinery rely on stable power. The GROADA load bank evaluates system robustness, identifies weaknesses, and minimizes downtime risks, ultimately protecting operational continuity and revenue.
Mission-critical operations require power systems that perform flawlessly under extreme conditions. The RLC Load Bank validates generators, UPS, and control systems, ensuring readiness in defense and aerospace applications.
As solar, wind, and hybrid energy solutions grow in adoption, testing their interaction with grid systems becomes essential. The RLC Load Bank simulates variable loads to evaluate system stability, voltage regulation, and power factor correction.
The GROADA RLC Load Bank adheres to globally recognized standards:
IEEE 1547: Distributed energy resource interconnection and performance testing.
IEEE 112.3 & 112.5: UPS performance verification standards.
NFPA 110: Emergency and standby power system testing and maintenance.
ISO 8528: Reciprocating engine-driven generator testing procedures.
IEC 62040: Performance and test requirements for UPS systems.
UL 1008: Safety requirements for transfer switches.
These certifications ensure that testing meets regulatory requirements, enabling safe deployment in diverse industries worldwide.
By simulating real operational loads, potential weaknesses in generators, alternators, batteries, and control panels are detected before they cause system failures.
Proactive testing reduces unexpected maintenance costs and extends equipment lifespan by identifying issues early.
Regular load testing ensures uninterrupted power supply, critical in healthcare, data centers, and telecom facilities.
Meeting ISO, IEEE, NFPA, and UL standards ensures organizations maintain compliance and safety across all operations.
By preventing downtime and optimizing power system performance, organizations save on energy costs, maintenance expenses, and emergency repair charges.
| 매개 변수 | 명세 |
|---|---|
| 로드 유형 | Resistive, Inductive, Capacitive |
| 전력 인자 | 0.1 – 1.0 Adjustable |
| 전압 | Single-phase 120V/220V/230V/240V, Three-phase 208V/380V/400V/415V |
| 주파수 | 50/60Hz |
| Measurement Accuracy | ±5% R, ±10% L/C |
| Control | Local touchscreen, Remote computer control |
| Dimensions | Customizable per model |
| 냉각 | Forced air or natural convection options |
| 안전 특징 | Overload protection, emergency stop, thermal sensors |
GROADA has decades of experience in designing and manufacturing load banks trusted by industries worldwide. Our products are:
Reliable: Engineered for precision and long-term durability.
Flexible: Suitable for a wide range of power systems and international voltage standards.
Safe: Compliant with global electrical safety standards.
User-Friendly: Advanced digital interface for easy monitoring and control.
Organizations from data centers to military bases rely on GROADA load banks to validate and maintain their electrical systems efficiently.
In an era where uninterrupted power supply is mission-critical, the GROADA RLC Load Bank provides unmatched precision, versatility, and reliability. By simulating realistic electrical loads, it ensures that generators, UPS systems, and industrial power infrastructures operate optimally under any condition.
Elevate your power testing capabilities with GROADA – the professional choice for engineers and organizations that demand accuracy, safety, and performance.