| 모델 | AC220V-5KW-RCD는 | AC220V-10KW-RCD는 | AC220V-15KW-RCD는 | AC220V-20KW-RCD는 | AC380V-30KW-RCD는 | AC380V-50KW-RCD는 | AC380V-60KW-RCD는 | AC380V-100KW-RCD는 | AC380V-200KW-RCD는 |
| 정격 전력 | R = 5KW | R = 10KW | R = 15KW | R = 20KW | R = 30KW | R = 50KW | R = 60KW | R = 100KW | R = 200KW |
| RCD = 5KVA | RCD = 10KVA | RCD = 15KVA | RCD = 20KVA | RCD = 30KVA | RCD = 50KVA | RCD = 60KVA | RCD = 100KVA | RCD = 200KVA | |
| 입력 현재 | 0-22A | 0-45A | 0-45A | 0-90A | 0-45A | 0-300A | 0-450A | 0-600A | 0-750A |
| 크기 (폭 * 깊이 * 높이 mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| 무게 | 50KG의 | 80KG의 | 100KG의 | 130KG의 | 200KG의 | 300KG의 | 350KG의 | 450KG의 | 550KG의 |
| 입력 전압 | AC220 / 230V | AC380/400V | |||||||
| 다른 입력 전압은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | |||||||||
| 최소 부하 | 100W | 100W | 100W | 100W | 100W | 1KW | 1KW | 1KW | 1KW |
| 다른 최소 적재 힘은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | |||||||||
| 전반적인 정확도 | 3% (다른 정확도 요구 사항은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 전력 요소 | PF = 0.6 ~ 1.0 | ||||||||
| 최고 계수 | 2에서 3까지 | ||||||||
| 제어 모드 | 지역 수동/원격 호스트 컴퓨터 (지역 수동 제어 모드: 차단기/버튼/터치 스크린 선택적 3 방향, 다른 방법은 필요에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 원격 인터페이스 | RS232/RS485/USB/RJ45/CAN/GPIB (다른 인터페이스 형태는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 보호 기능 | 비상 정지 보호, 과온 보호, 팬 부하 인터로크 보호, 접지 보호 (과전압 보호, 과전류 보호, 단회로 보호, 팬 과부하, 부족한 공기 용량을 선택하십시오) | ||||||||
| 작동 전원 공급 | AC220V는 | AC220V / AC380V | |||||||
| 표시 정확도 | 0.5 수준 (다른 명시적인 정밀도는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 표시 매개 변수 | 전압, 전류, 힘, 주파수, 전력 요인 등. (다른 명시적인 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 차가운 확실한 방법 | 측면 공기 입구 및 위 공기 출구 (다른 공기 출구 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 보호 수준 | IP20 (다른 보호 수준은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 외관 색깔 | RAL7035 (다른 색깔은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 작동 온도 | -10 ℃ ~ 55 ℃ | ||||||||
| 상대 습도 | ≤95%RH | ||||||||
| 고도 | ≤ 2500 m | ||||||||
전력 시스템의 신뢰성과 효율성을 보장하기 위해 실제 운영 조건을 정확하게 복제하는 테스트 솔루션이 필요합니다.TheGROADA AC220V 20KW RCD 비선형 부하 은행이 요구를 충족시키기 위해 엔지니어링되어 있으며 발전기, UPS 시스템, 인버터 및 기타 중요한 전력 장비에 대한 고급 비선형 부하 시뮬레이션을 제공합니다.산업 및 상업용 어플리케이션을 위해 설계된 이 로드 이 이 산이 이 로드 산산업업용 및 상업용 어플리케이션을 위해 설계된 이 로드 산산업산업용 및 상업용 어플리케이션을 위해 설계된 이 로드 산크는
정격 전력으로20 kW이 부하 은행은 소형 산업 발전기부터 대형 UPS 시스템까지 다양한 장비를 테스트할 수 있는 충분한 용량을 제공합니다.
최적화된AC 220V systems, it is versatile enough for diverse applications across different industries, ensuring seamless integration into existing electrical setups.
Unlike traditional resistive-only load banks, the RCD load bank combines resistive and capacitive elements, accurately replicating the nonlinear characteristics of modern electrical loads. This ensures testing reflects real operational conditions, particularly for electronic-heavy loads.
Equipped with an adjustable power factor range from 0.7 to 1, the load bank allows users to simulate varying load conditions, enabling thorough evaluation of power sources under both light and heavy reactive loads.
The built-in LCD display provides real-time monitoring of key electrical parameters such as voltage, current, power, and power factor. This ensures operators have full visibility over testing conditions at all times.
Protective systems for overcurrent, overvoltage, and thermal management safeguard both the load bank and the equipment under test, minimizing risk during rigorous testing operations.
| 매개 변수 | 명세 |
|---|---|
| 정격 전력 | 20 kW |
| 명목적 전압 | AC 220V |
| 로드 유형 | Resistive + Capacitive (Nonlinear) |
| 전력 인자 범위 | 0.7 – 1 |
| 디스플레이 | LCD |
| 보호 특징 | Overcurrent, Overvoltage |
| 냉각 방법 | Forced Air |
The GROADA 20KW RCD Nonlinear Load Bank is ideal for a broad range of professional applications, including:
Generators – Ensures reliable performance under dynamic loads, preventing overload and downtime.
Uninterruptible Power Supplies (UPS) – Verifies the ability to support critical loads during power interruptions.
Inverters – Assesses performance in real-world scenarios with fluctuating and nonlinear loads.
데이터 센터 – Simulates operational loads to maintain uptime and system reliability.
Telecommunications Equipment – Confirms network stability under complex electrical conditions.
This versatility makes it an essential tool for testing, commissioning, and maintaining critical electrical systems.
Realistic Load Testing – Accurately replicates nonlinear electrical loads for true-to-life testing scenarios.
Comprehensive Monitoring – Provides precise, real-time data for informed decision-making.
Safe and Reliable Operation – Advanced protection mechanisms ensure equipment safety during testing.
Wide Application Scope – Suitable for industrial, commercial, and mission-critical power systems.
Industry Standard Compliance – Meets global standards for load testing, guaranteeing accuracy and credibility.
Modern power systems are increasingly exposed to nonlinear and dynamic loads due to the proliferation of electronic devices and renewable energy sources. Traditional load testing methods often fail to replicate these conditions accurately, leading to overestimation of equipment capacity or premature failures. The GROADA AC220V 20KW RCD Load Bank bridges this gap, ensuring your generators, UPS systems, and inverters are fully prepared for real-world operational stresses.
TheGROADA AC220V 20KW RCD 비선형 부하 은행 is more than a testing device – it is a tool for safeguarding your power infrastructure. Its combination of nonlinear load simulation, adjustable power factor, real-time monitoring, and robust safety features makes it indispensable for industries where electrical reliability is critical. Whether for industrial generators, data centers, or telecommunication networks, this load bank ensures your systems perform optimally, every time.