GROADA-AC220V-15KW-RLC 부하 은행 제조 업체
The GROADA AC220V 15KW RLC Load Bank is engineered to provide comprehensive simulation of real-world...
| 모델 | AC220V-10KVA-RLC는 | AC380V-30KVA-RLC는 | AC380V-60KVA-RLC는 | AC380V-100KVA-RLC는 | AC380V-200KVA-RLC는 | AC380V-300KVA-RLC는 |
| 정격 전력 | RLC = 10KVA | RLC = 30KVA | RLC = 60KVA | RLC = 100KVA | RLC = 200KVA | RLC = 300KVA |
| R = 10KW;L = 10KVA C = 10KVA | R=30KW;L=30KVA; C = 30KVA | R=60KW;L=60KVA; C = 60KVA | R=100KW;L=100KVA; C = 100KVA | R=200KW;L=200KVA; C = 200KVA | R=300KW;L=300KVA; C = 300KVA | |
| 다른 힘은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | ||||||
| 크기 (폭 * 깊이 * 높이 mm) | 500*750*1400 | 600*850*1500 | 1000*1100*1500 | 1100*1600*1500 | 1500*1800*1800 | 2000*2000*2000 |
| 무게 | 120KG의 | 380KG의 | 580KG의 | 880KG의 | 1500KG의 | 2500KG의 |
| 입력 전압 | AC220 / 230V | AC380/400V | ||||
| 다른 입력 전압은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | ||||||
| 입력 현재 | 0-45A | 0-45A | 0-90A | 0-150A | 0-300A | 0-450A |
| 최소 부하 | R = 100W;L=100VA; C = 100VA | R = 100W;L=100VA; C = 100VA | R = 100W;L=100VA; C = 100VA | R = 100W;L=100VA; C = 100VA | R = 1KW;L = 1KVA; C = 1KVA | R = 1KW;L = 1KVA; C = 1KVA |
| 다른 최소 적재 힘은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | ||||||
| 전력 요소 | PF = 0.1~1.0 (다른 전력 요인은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 전반적인 정확도 | 3% (다른 정확도 요구 사항은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 제어 모드 | 지역 수동/원격 호스트 컴퓨터 (지역 수동 제어 모드: 차단기/버튼/터치 스크린 선택적 3 방향, 다른 방법은 필요에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 원격 인터페이스 | RS232/RS485/USB/RJ45/CAN/GPIB (다른 인터페이스 형태는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 보호 기능 | 비상 정지 보호, 과온 보호, 팬 부하 인터로크 보호, 접지 보호 (과전압 보호, 과전류 보호, 단회로 보호, 팬 과부하, 부족한 공기 용량을 선택하십시오) | |||||
| 작동 전원 공급 | AC220V는 | AC220V / 380V | AC380V는 | |||
| 표시 정확도 | 0.5 수준 (다른 명시적인 정밀도는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 표시 매개 변수 | 전압, 전류, 힘, 주파수, 전력 요인 등. (다른 명시적인 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 차가운 확실한 방법 | 측면 공기 입구 및 위 공기 출구 (다른 공기 출구 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 보호 수준 | IP20 (다른 보호 수준은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 외관 색깔 | RAL7035 (다른 색깔은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | |||||
| 작동 온도 | -10 ℃ ~ 55 ℃ | |||||
| 상대 습도 | ≤95%RH | |||||
| 고도 | ≤ 2500 m | |||||
전력 인프라를 통해 최적의 성능, 신뢰성 및 안전 보장
TheGROADA AC380V 20KW RLC 부하 은행전력 생산 및 유통 시스템의 신뢰성과 효율성을 검증하기 위해 설계된 고성능 테스트 솔루션입니다.결합저항, 유도 및 용량 부하실제 전기 조건을 시뮬레이션하여 엔지니어와 기술자를 가능하게 합니다.중요한 실패가 되기 전에 잠재적 인 문제를 식별하십시오..
발전기, UPS 시스템, 데이터 센터 또는 재생 가능 에너지 통합에 대한 상관없이,정확하고 반복 가능하고 안전한 테스트 결과모든 시나리오에서 중요한 전력 시스템이 최고 효율으로 작동하도록 보장합니다.
회사저항 (R), 유도 (L), 용량 (C) 부하실제 전기 시스템의 행동을 정확하게 복제하기 위해.
반응적 및 비선형 부하를 포함한 다양한 부하 유형의 정확한 시뮬레이션을 허용합니다.
A 지원0.1에서 1.0까지의 광범위한 전력 요소 범위다양한 작동 조건에서 테스트를 가능하게 합니다.
반응적 부하가 존재하는 애플리케이션에서 시스템 성능을 검증하는 데 중요합니다.
모듈형 아키텍처는쉬운 확장성특정 테스트 요구에 따라 사용자 정의 할 수 있습니다.
Compact, robust, and transportable design ensures versatility in both field and laboratory environments.
Intuitive control panel provides real-time monitoring of voltage, current, power, and power factor.
Optional remote control functionality allows for safe operation from a distance.
장착된overload protection, short-circuit protection, and over-temperature alarms.
Ensures operator safety and prevents damage to both the load bank and tested equipment.
Simulates realistic load conditions to verify generator performance, efficiency, and reliability.
Ensures compliance with operational standards and minimizes the risk of failure during peak demand.
Tests UPS functionality under varied resistive, inductive, and capacitive loads.
Ensures backup power systems maintain reliability during outages.
Evaluates solar, wind, or hybrid power systems under dynamic load conditions.
Helps optimize inverter and storage system performance for consistent energy delivery.
Confirms that backup power systems and generators can handle high-demand, critical loads.
Prevents downtime and ensures business continuity.
The GROADA AC380V 20KW RLC Load Bank is designed to meet international safety and performance standards, ensuring both reliability and operational compliance:
IEEE 1547 – Standard for testing distributed energy resources.
NFPA 110 – Requirements for emergency and standby power systems.
ISO 8528-10 – Load acceptance testing standards for generating sets.
Compliance with these standards guarantees that the load bank can be safely and effectively integrated into professional power testing environments worldwide.
Reliability Assurance – Early detection of system weaknesses prevents critical failures.
Performance Optimization – Testing under real-world load conditions ensures generators, UPS units, and other systems perform efficiently.
Cost Efficiency – Proactive testing reduces costly emergency repairs and downtime.
Operational Confidence – Verifies that backup power systems are ready for emergency operation.
| 명세 | 세부 정보 |
|---|---|
| 정격 전력 | 20KW |
| 전압 | AC380V는 |
| 주파수 | 50/60Hz |
| 전력 인자 | 0.1 – 1.0 |
| 제어 모드 | Local panel and optional remote |
| 안전 특징 | Overload, short circuit, over-temp alarms |
GROADA RLC Load Banks are trusted globally by power generation companies, data centers, and critical infrastructure operators. Our solutions are engineered for accuracy, durability, and ease of use, providing peace of mind for engineers and facility managers alike.
Email: groadacn@163.com
Phone: +86-755-23339096