GROADA-AC120V-5KW-RCD 부하 은행 제조 업체
The GROADA AC120V-5KW RCD Load Bank is a high-precision testing device designed to simulate nonlinea...
| 모델 | AC220V-5KW-RCD는 | AC220V-10KW-RCD는 | AC220V-15KW-RCD는 | AC220V-20KW-RCD는 | AC380V는 -30KW-RCD | AC380V는 -50KW-RCD | AC380V는 - 60KW-RCD | AC380V는 - 100KW-RCD | AC380V는 -200KW-RCD |
| 정격 전력 | R = 5KW | R = 10KW | R = 15KW | R = 20KW | R = 30KW | R = 50KW | R = 60KW | R = 100KW | R = 200KW |
| RCD = 5KVA | RCD = 10KVA | RCD = 15KVA | RCD = 20KVA | RCD = 30KVA | RCD = 50KVA | RCD = 60KVA | RCD = 100KVA | RCD = 200KVA | |
| 입력 현재 | 0-22A | 0-45A | 0-45A | 0-90A | 0-45A | 0-300A | 0-450A | 0-600A | 0-750A |
| 크기 (폭 * 깊이 * 높이 mm) | 500*600*800 | 500*600*1000 | 500*600*1100 | 500*750*1100 | 600*850*1400 | 600*850*1600 | 600*850*1850 | 700*1000*1800 | 1100*1400*1800 |
| 무게 | 50KG의 | 80KG의 | 100KG의 | 130KG의 | 200KG의 | 300KG의 | 350KG의 | 450KG의 | 550KG의 |
| 입력 전압 | AC220 / 230V | AC380/400V | |||||||
| 다른 입력 전압은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | |||||||||
| 최소 부하 | 100W | 100W | 100W | 100W | 100W | 1KW | 1KW | 1KW | 1KW |
| 다른 최소 적재 힘은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다 | |||||||||
| 전반적인 정확도 | 3% (다른 정확도 요구 사항은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 전력 요소 | PF = 0.6 ~ 1.0 | ||||||||
| 최고 계수 | 2에서 3까지 | ||||||||
| 제어 모드 | 지역 수동/원격 호스트 컴퓨터 (지역 수동 제어 모드: 차단기/버튼/터치 스크린 선택적 3 방향, 다른 방법은 필요에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 원격 인터페이스 | RS232/RS485/USB/RJ45/CAN/GPIB (다른 인터페이스 형태는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 보호 기능 | 비상 정지 보호, 과온 보호, 팬 부하 인터로크 보호, 접지 보호 (과전압 보호, 과전류 보호, 단회로 보호, 팬 과부하, 부족한 공기 용량을 선택하십시오) | ||||||||
| 작동 전원 공급 | AC220V는 | AC220V / AC380V | |||||||
| 표시 정확도 | 0.5 수준 (다른 명시적인 정밀도는 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 표시 매개 변수 | 전압, 전류, 힘, 주파수, 전력 요인 등. (다른 명시적인 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 차가운 확실한 방법 | 측면 공기 입구 및 위 공기 출구 (다른 공기 출구 방법은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 보호 수준 | IP20 (다른 보호 수준은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 외관 색깔 | RAL7035 (다른 색깔은 요구 사항에 따라 주문을 받아서 만들어질 수 있습니다) | ||||||||
| 작동 온도 | -10 ℃ ~ 55 ℃ | ||||||||
| 상대 습도 | ≤95%RH | ||||||||
| 고도 | ≤ 2500 m | ||||||||
TheGROADA AC380V 30KW RCD 부하 은행현대 전력 시스템을 테스트하고 검증하는 최신 솔루션입니다.실제 전기 조건을 복제하도록 설계되었으며, 정확한 시뮬레이션을 제공합니다.비선형 부하엔지니어가 발전기, UPS 시스템, 인버터 및 기타 중요한 전력 장비의 성능, 효율성 및 신뢰성을 평가할 수 있도록 합니다.
산업 운영, 데이터 센터 또는 재생 가능 에너지 설치를 위해, 이 로드 이 이 이 은행은 시스템이 견고하고 탄력적이며 모든 전기 시나리오에 적합하도록 보장합니다.
| 특징 | 명세 |
|---|---|
| 정격 전력 | 30 kW (저항) / 30 kVA (용량) |
| 전압 | AC 380V, 3 단계 |
| 주파수 | 50/60 Hz의 |
| 전력 인자 범위 | 0.6 – 1.0 (adjustable) |
| 최대 현재 | Up to 576A (3-phase) |
| 로드 유형 | Resistive-Capacitive (RCD) |
| 안전 보호 | Overcurrent, overvoltage, overtemperature, emergency stop |
Key Insight: The combination of resistive and capacitive elements allows this load bank to generate non-linear load profiles that closely mimic modern electronic equipment behavior, ensuring realistic testing conditions.
Modern electrical systems often encounter 비선형 부하 due to electronic devices like computers, servers, and inverters. The RCD load bank replicates these conditions, allowing engineers to evaluate power system performance, including voltage stability, current harmonics, and thermal response under real operating scenarios.
Thepower factor adjustment range (0.6–1.0) ensures that your equipment can be tested under a variety of load conditions, from capacitive-heavy to predominantly resistive loads. This flexibility is critical for validating UPS, generator, and inverter performance under diverse operational scenarios.
With the ability to handle up to 576A in three-phase configurations, this load bank is suitable for medium to high-capacity power systems. It allows full-load testing without overloading the equipment under test, ensuring reliability and operational safety.
Safety is paramount in load testing. The GROADA RCD Load Bank is equipped with:
Overcurrent protection to prevent excessive load damage
Overvoltage protection to safeguard connected equipment
Overtemperature protection for internal heating control
Emergency stop for immediate shutdown during unexpected situations
The digital display provides continuous monitoring of:
Voltage and current
Real-time power consumption
Power factor and load distribution
This ensures precise, data-driven testing with minimal operator error.
The GROADA AC380V 30KW RCD Load Bank is ideal across multiple sectors:
데이터 센터: Test UPS and backup generators under realistic, fluctuating load conditions.
통신: Validate the reliability of inverters and backup power for mission-critical networks.
Industrial Manufacturing: Confirm generator and electrical system resilience in factories and production facilities.
재생 가능한 에너지: Evaluate inverters and hybrid energy systems in solar and wind installations to ensure optimal performance.
This load bank aligns with industry standards and best practices, including:
IEEE 1547 – Interconnection and performance of distributed energy resources
IEEE 112.3 – Generator testing methods
ISO 8528 – Reciprocating internal combustion engine-driven generating sets
Compliance guarantees trustworthy, repeatable testing results for both local and international projects.
Enhanced Testing Accuracy: Realistic simulation of non-linear loads ensures precise system evaluation.
Wide Application Range: Suitable for data centers, industrial sites, telecom networks, and renewable energy projects.
Long-Term Reliability: High-quality components for consistent performance over time.
Operator Safety: Built-in protections and emergency stop mechanisms safeguard users and equipment.
Investing in the GROADA AC380V 30KW RCD Load Bank means preparing your power systems for real-world demands, minimizing downtime, and optimizing operational efficiency.